Percutaneous Iliosacral Screw Insertion: Malpositioning and Revision Rate of Screws With Regards to Application Technique (Navigated Vs. Conventional)

被引:81
作者
Zwingmann, J. [1 ]
Konrad, G. [1 ]
Mehlhorn, A. T. [1 ]
Suedkamp, N. P. [1 ]
Oberst, M. [1 ]
机构
[1] Univ Freiburg, Med Ctr, Dept Orthopaed & Trauma Surg, D-79106 Freiburg, Germany
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2010年 / 69卷 / 06期
关键词
Iliosacral screw; SI screw; Navigation; Pelvic fracture; SACROILIAC SCREWS; SACRAL FRACTURES; SUPINE POSITION; PLACEMENT; FIXATION; SURGERY; SYSTEM; JOINT; STABILIZATION; FLUOROSCOPY;
D O I
10.1097/TA.0b013e3181d862db
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Conventional percutaneous iliosacral screw placement in pelvic surgery is considered to be a highly demanding operative technique with a high rate of screw malpositions, which may be associated with the risk of neurologic damage or inefficient stability. In the conventional technique, the correct entry point for the screw and the small target corridor for the iliosacral screw may be difficult to visualize using an image intensifier. We tried to find out in this study whether the positioning of percutaneous screw implantations could be optimized by evaluating the rate and grade of malpositions and whether the needed revisions could be reduced by using computer navigation and three-dimensional (3D) image intensifier. Methods: A group of 54 patients with 63 screws implanted using computer navigation was compared with 87 patients with 131 screws implanted using the conventional fluoroscopic technique. The exact screw position was controlled in a postoperative computed tomography scan, and the grade of malposition of every screw was investigated and compared. Results: A complete intraosseous screw position was found in 42% of cases using the conventional technique and was significantly less compared with 81% using a 3D image intensifier in combination with a navigation system. Moreover, the revision rate of 1.6% was significantly less in the navigated group compared with 19% in the conventional group. Conclusions: The results indicate that 3D-computer navigation of the percutaneous iliosacral screw insertion can facilitate surgical performance in respect to reducing screw malposition and revision rates.
引用
收藏
页码:1501 / 1506
页数:6
相关论文
共 28 条
[11]   Imaging assessment of sacroiliac screw placement relative to the neuroforamen [J].
Goldberg, BA ;
Lindsey, RW ;
Foglar, C ;
Hedrick, TD ;
Miclau, T ;
Hadad, JL .
SPINE, 1998, 23 (05) :585-589
[12]  
Hinsche AF, 2002, CLIN ORTHOP RELAT R, P135
[13]  
Hüfner T, 2004, CHIRURG, V75, P961, DOI 10.1007/s00104-004-0945-2
[14]   Early fixation of the vertically unstable pelvis: The role of iliosacral screw fixation of the posterior lesion [J].
Keating, JF ;
Werier, J ;
Blachut, P ;
Broekhuyse, H ;
Meek, RN ;
O'Brien, PJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (02) :107-113
[15]   CT-GUIDED FIXATION OF SACRAL FRACTURES AND SACROILIAC JOINT DISRUPTIONS [J].
NELSON, DW ;
DUWELIUS, PJ .
RADIOLOGY, 1991, 180 (02) :527-532
[16]  
Routt ML, 1996, CLIN ORTHOP RELAT R, P121
[17]  
ROUTT MLC, 1995, J ORTHOP TRAUMA, V9, P207
[18]   Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain [J].
Schep, NWL ;
Haverlag, R ;
van Vugt, AB .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (06) :1299-1302
[19]   An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws [J].
Smith, HE ;
Yuan, PS ;
Sasso, R ;
Papadopolous, S ;
Vaccaro, AR .
SPINE, 2006, 31 (02) :234-238
[20]   Pseudoaneurysm of the superior gluteal arterial system: An unusual cause of pain after a pelvic fracture [J].
Stephen, DJG .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 43 (01) :146-149