Towards Video Guidance for Ultrasound, Using a Prior High-Resolution 3D Surface Map of the External Anatomy

被引:0
作者
Wang, Jihang [1 ]
Shivaprabhu, Vikas [1 ]
Galeotti, John [1 ,2 ]
Horvath, Samantha [2 ]
Gorantla, Vijay [3 ]
Stetten, George [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15260 USA
[2] Carnegie Mellon Univ, Inst Robot, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh Med Ctr, Dept Reconstruct Surg, Pittsburgh, PA USA
来源
AUGMENTED ENVIRONMENTS FOR COMPUTER-ASSISTED INTERVENTIONS (AE-CAI 2014) | 2014年 / 8678卷
关键词
ultrasound; tracking; anatomical coordinates; computer vision; guidance; ProbeSight; TRACKING;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We are developing techniques for guiding ultrasound probes and other clinical tools with respect to the exterior of the patient, using one or more video camera(s) mounted directly on the probe or tool. This paper reports on a new method of matching the real-time video image of the patient's exterior against a prior high-resolution surface map acquired with a multiple-camera imaging device used in reconstructive surgery. This surface map is rendered from multiple viewpoints in real-time to find the viewpoint that best matches the probe-mounted camera image, thus establishing the camera's pose relative to the anatomy. For ultrasound, this will permit the compilation of 3D ultrasound data as the probe is moved, as well as the comparison of a real-time ultrasound scan with previous scans from the same anatomical location, all without using external tracking devices. In a broader sense, tools that know where they are by looking at the patient's exterior could have an important beneficial impact on clinical medicine.
引用
收藏
页码:51 / +
页数:2
相关论文
共 19 条
[1]  
[Anonymous], 1966, Photogrammetric Engineering and Remote Sensing
[2]   A needle tracking device for ultrasound guided percutaneous procedures [J].
Chan, C ;
Lam, F ;
Rohling, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (11) :1469-1483
[3]   A REAL-TIME FREEHAND ULTRASOUND CALIBRATION SYSTEM WITH AUTOMATIC ACCURACY FEEDBACK AND CONTROL [J].
Chen, Thomas Kuiran ;
Thurston, Adrian D. ;
Ellis, Randy E. ;
Abolmaesumi, Purang .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (01) :79-93
[4]  
Dewi D., 2009, ICICI BME
[5]  
Flaccavento G, 2004, LECT NOTES COMPUT SC, V3217, P585
[6]  
FRYER JG, 1986, PHOTOGRAMM ENG REM S, V52, P51
[7]  
Gobbi D. G., 2002, Medical Image Computing and Computer-Assisted Intervention - MICCAI 2002. 5th International Conference. Proceedings, Part II (Lecture Notes in Computer Science Vol.2489), P156
[8]  
Khamene A., 2002, US Patent, Patent No. 6612991
[9]  
Krupa A, 2007, LECT NOTES COMPUT SC, V4792, P1
[10]  
Lasso A., 2012, proc. of Medical Image Computing and Computer-Assisted Intervention (MICCAI), P1