Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2

被引:19
作者
Hong, Christine
Peter Truong
Ha Na Song
Wu, Benjamin M. [2 ,3 ,4 ]
Moon, Won [1 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Sect Orthodont, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Calif NanoSyst Inst, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Sch Engn, Los Angeles, CA 90095 USA
关键词
Mini-implants; TADs; Stability; Buccal bone thickness; Cortical bone; Micro-CT; CORTICAL BONE THICKNESS; DISTAL MOVEMENT; ANCHORAGE; ROOT; DISTALIZATION; PROXIMITY; FAILURE; LENGTH; MOLARS; SHAPE;
D O I
10.2319/031011-176.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the mechanical stability of a newly revised orthodontic mini-implant design (N2) compared with a design introduced in Part 1 of the study (N1) and the most widely-used commercially-available design (CA). To evaluate the mean buccal bone thickness of maxillary and mandibular posterior teeth using cone-beam computed tomography (CBCT). Materials and Methods: From the CBCT scans of 20 patients, six tomographic cross-sections were generated for each tooth. Buccal bone thickness was measured from the most convex point on the bone to the root surface. CA (1.5 mm in diameter and 6 mm in length), N1, and N2 (shorter and narrower than N1) were inserted in simulated bone with cortical and trabecular bone layers. Mechanical stability was compared in vitro through torque and lateral displacement tests. Results: The bone thickness ranged from 2.26 to 3.88 mm. Maximum insertion torque was decreased significantly in N2 compared to N1. However, force levels for all displacement distances and torque ratio were the highest in N2, followed by N1 and CA (alpha = .05). Conclusions: Both torque and lateral displacement tests highlighted the enhanced stability of N2 compared with CA. Design revisions to N1 effectively mitigated N1's high insertion torque and thus potentially reduced microdamage to the surrounding bone. The N2 design is promising as evidenced by enhanced stability and high mechanical efficiency. Moreover, N2 is not limited to placement in interradicular spaces and has the capacity to be placed in the buccal bone superficial to the root surface with diminished risk of endangering nearby anatomic structures during placement and treatment. (Angle Orthod. 201181:1001-1009.)
引用
收藏
页码:1001 / 1009
页数:9
相关论文
共 50 条
[31]   Assessment of interradicular areas and cortical bone thickness for orthodontic mini-implant placement: a cone-beam computed tomography study [J].
Gupta, Sanjay Prasad ;
Niroula, Deepa ;
Budha Magar, Nisha .
BMC ORAL HEALTH, 2025, 25 (01)
[32]   Analysis of the association of IL4 polymorphisms with orthodontic mini-implant loss [J].
Lopes, T. F. ;
Souza, C. M. ;
Reichow, A. M. ;
Melo, A. C. ;
Trevilatto, P. C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (07) :982-988
[33]   A healing period increases mini-implant stability in growing rats [J].
Yano, Shinya ;
Motoyoshi, Mitsuru ;
Inaba, Mizuki ;
Yano, Saori ;
Takenouchi, Hiroyuki ;
Son, Seil ;
Arai, Yoshinori ;
Shimizu, Noriyoshi .
JOURNAL OF ORAL SCIENCE, 2014, 56 (02) :113-118
[34]   Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability [J].
Baek, Sun-Hye ;
Cha, Hyun-Suk ;
Cha, Jung-Yul ;
Moon, Yoon-Shik ;
Sung, Sang-Jin .
KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (04) :159-168
[35]   Effect of Splinting on Orthodontic Mini-Implant Tipping and Bone Histomorphometric Parameters: An In Vivo Animal Model Study [J].
Fontes, Joana ;
Martin, Victor Zacharias ;
Resende, Marta ;
Colaco, Bruno ;
Gomes, Pedro de Sousa ;
Amarante, Jose Manuel .
JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (05)
[36]   Orthodontic mini-implant diameter does not affect in-situ linear microcrack generation in the mandible or the maxilla [J].
Liu, Sean Shih-Yao ;
Cruz-Marroquin, Enrique ;
Sun, Jun ;
Stewart, Kelton T. ;
Allen, Matthew R. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (06) :768-773
[37]   Analysis for Predictors of Failure of Orthodontic Mini-implant Using Patient-Specific Finite Element Models [J].
Toriya, Takahiro ;
Kitahara, Toru ;
Hyakutake, Hiroto ;
Todo, Mitsugu ;
Takahashi, Ichiro .
ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (03) :594-603
[38]   The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study [J].
Cho, Il-Sik ;
Choo, HyeRan ;
Kim, Seong-Kyun ;
Shin, Yun-Seob ;
Kim, Duck-Su ;
Kim, Seong-Hun ;
Chung, Kyu-Rhim ;
Huang, John C. .
KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (05) :354-360
[39]   Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography [J].
Fayed, Mona Mohamed Salah ;
Pazera, Pawel ;
Katsaros, Christos .
ANGLE ORTHODONTIST, 2010, 80 (05) :939-951
[40]   Unilateral intrusion in a medically complex patient using an orthodontic mini-implant: A case report [J].
Gibson, Clara ;
Critchlow, Simon ;
Patel, Brijesh .
JOURNAL OF ORTHODONTICS, 2021, 48 (04) :435-443