Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2

被引:19
作者
Hong, Christine
Peter Truong
Ha Na Song
Wu, Benjamin M. [2 ,3 ,4 ]
Moon, Won [1 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Sect Orthodont, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Calif NanoSyst Inst, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Sch Engn, Los Angeles, CA 90095 USA
关键词
Mini-implants; TADs; Stability; Buccal bone thickness; Cortical bone; Micro-CT; CORTICAL BONE THICKNESS; DISTAL MOVEMENT; ANCHORAGE; ROOT; DISTALIZATION; PROXIMITY; FAILURE; LENGTH; MOLARS; SHAPE;
D O I
10.2319/031011-176.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the mechanical stability of a newly revised orthodontic mini-implant design (N2) compared with a design introduced in Part 1 of the study (N1) and the most widely-used commercially-available design (CA). To evaluate the mean buccal bone thickness of maxillary and mandibular posterior teeth using cone-beam computed tomography (CBCT). Materials and Methods: From the CBCT scans of 20 patients, six tomographic cross-sections were generated for each tooth. Buccal bone thickness was measured from the most convex point on the bone to the root surface. CA (1.5 mm in diameter and 6 mm in length), N1, and N2 (shorter and narrower than N1) were inserted in simulated bone with cortical and trabecular bone layers. Mechanical stability was compared in vitro through torque and lateral displacement tests. Results: The bone thickness ranged from 2.26 to 3.88 mm. Maximum insertion torque was decreased significantly in N2 compared to N1. However, force levels for all displacement distances and torque ratio were the highest in N2, followed by N1 and CA (alpha = .05). Conclusions: Both torque and lateral displacement tests highlighted the enhanced stability of N2 compared with CA. Design revisions to N1 effectively mitigated N1's high insertion torque and thus potentially reduced microdamage to the surrounding bone. The N2 design is promising as evidenced by enhanced stability and high mechanical efficiency. Moreover, N2 is not limited to placement in interradicular spaces and has the capacity to be placed in the buccal bone superficial to the root surface with diminished risk of endangering nearby anatomic structures during placement and treatment. (Angle Orthod. 201181:1001-1009.)
引用
收藏
页码:1001 / 1009
页数:9
相关论文
共 50 条
  • [21] Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region
    Jia, Xueting
    Chen, Xing
    Huang, Xiaofeng
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (05) : 656 - 661
  • [22] The impact of healing time before loading on orthodontic mini-implant stability: A histomorphometric study in minipigs
    Oltramari-Navarro, Paula V. P.
    Navarro, Ricardo L.
    Henriques, Jose Fernando C.
    Cestari, Tania M.
    Francischone, Carlos E.
    Taga, Rumio
    McNamara, James A., Jr.
    [J]. ARCHIVES OF ORAL BIOLOGY, 2013, 58 (07) : 806 - 812
  • [23] Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods
    Nienkemper, Manuel
    Santel, Natascha
    Hoenscheid, Ralf
    Drescher, Dieter
    [J]. JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2016, 77 (04): : 296 - 303
  • [24] Horizontal Pull-Out Strength of Orthodontic Infrazygomatic Mini-Implant: An In Vitro Study
    Chen, Chun-Ming
    Wu, Ju-Hui
    Lu, Pei-Chen
    Wang, Huang-Chi
    Lee, Huey-Er
    Wang, Chau-Hsiang
    Du, Je-Kang
    [J]. IMPLANT DENTISTRY, 2011, 20 (02) : 139 - 145
  • [25] Primary stability and viscoelastic displacement of mini-implant system under loading
    Lee, Jim
    Jeong, Yong-Hoon
    Pittman, Joseph
    Deguchi, Toru
    Johnston, William M.
    Fields, Henry W.
    Kim, Do-Gyoon
    [J]. CLINICAL BIOMECHANICS, 2017, 41 : 28 - 33
  • [26] Stability comparison between commercially available mini-implants and a novel design: Part 1
    Hong, Christine
    Lee, Haofu
    Webster, Richard
    Kwak, Jinny
    Wu, Benjamin M.
    Moon, Won
    [J]. ANGLE ORTHODONTIST, 2011, 81 (04) : 692 - 699
  • [27] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shen, Shuning
    Sun, Yingying
    Zhang, Chen
    Yang, Yongjin
    Li, Zhiren
    Cai, Xingwei
    Duan, Yinzhong
    Li, Tao
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 109 - 116
  • [28] Recommended placement torque when tightening an orthodontic mini-implant
    Motoyoshi, M
    Hirabayashi, M
    Uemura, M
    Shimizu, N
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (01) : 109 - 114
  • [29] Primary migration of a mini-implant under a functional orthodontic loading
    Pittman, Joseph W.
    Navalgund, Anand
    Byun, Steve H.
    Huang, Hechang
    Kim, Albert H.
    Kim, Do-Gyoon
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 721 - 728
  • [30] A prospective study of factors associated with orthodontic mini-implant survival
    Tsai, Chia-Chun
    Chang, Hong-Po
    Pan, Chin-Yun
    Chou, Szu-Ting
    Tseng, Yu-Chuan
    [J]. JOURNAL OF ORAL SCIENCE, 2016, 58 (04) : 515 - 521