Highly selective colorimetric detection of Zn(II) ions using label-free silver nanoparticles

被引:33
作者
Lee, Sujin [1 ,2 ,3 ]
Nam, Yun-Sik [1 ,2 ]
Lee, Ho-Jin [1 ,2 ]
Lee, Yeonhee [1 ,2 ]
Lee, Kang-Bong [1 ,2 ,3 ]
机构
[1] Korea Inst Sci & Technol, Adv Anal Ctr, Hwarang Ro 14 Gil 5, Seoul 136791, South Korea
[2] Korea Inst Sci & Technol, Green City Technol Inst, Hwarang Ro 14 Gil 5, Seoul 136791, South Korea
[3] Univ Sci & Technol, 217 Gajeong Ro, Daejeon 305350, South Korea
关键词
Colorimetric sensor; Label free silver nanoparticle; Zinc ion sensing; Borohydride anion; Sodium dodecylbenzenesulfonate; GOLD NANOPARTICLES; TOXIC METALS; ZINC; SENSOR; BOROHYDRIDE; CHEMOSENSOR; GROWTH; WATERS; NA;
D O I
10.1016/j.snb.2016.06.141
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and facile colorimetric method for the detection of zinc ions (Zn2+) using label-free silver nanoparticles (AgNPs) has been developed. Zn2+ ions induced the aggregation of label-free AgNPs in solution, resulting in a color change from yellow to forest green, which was accompanied by the appearance of a new surface plasmon absorption band at 635 nm. The sensitivity of label-free AgNPs towards other metal ions was negligible, with the exception of Fe3+, which caused a modest interference. The binding site and sensing mechanism for Zn2+ ions in label-free AgNPs were characterized by Fourier Transform infrared spectroscopy, ultraviolet-visible spectroscopy, and transmission electron microscopy. The aggregation of AgNPs in the presence of Zn2+ ions was inhibited by polyvinyl alcohol, which formed a shell on the surface of AgNPs. Furthermore, Zn2+ ions coordinated with BH4- on AgNPs through a triangular sixdentate binding structure, thus inducing aggregation of AgNPs in solution. The sensor conditions were optimized with 6.0 mu M of sodium dodecylbenzenesulfonate (NaDDBS) and 0.23 mM AgNPs at pH 6. The absorption ratios (A(635)/A(390)) of the label-free AgNPs solution exhibited a linear correlation with Zn2+ ion concentration within the range of 0.0 - 7.6 x 10(-6) mol L-1, with a limit of detection of 0.36 x 10(-6) mol L-1. This cost-effective sensing system allows rapid and facile determination of Zn2+ ions in various types of biological, mineral supplement, and environmental samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:643 / 651
页数:9
相关论文
共 53 条
[1]   Synthesis and applications of silver nanoparticles [J].
Abou El-Nour, Kholoud M. M. ;
Eftaiha, Ala'a ;
Al-Warthan, Abdulrhman ;
Ammar, Reda A. A. .
ARABIAN JOURNAL OF CHEMISTRY, 2010, 3 (03) :135-140
[2]   Hydrogen storage materials protected by a polymer shell [J].
Borodina, Tatiana ;
Grigoriev, Dmitry ;
Moehwald, Helmuth ;
Shchukin, Dmitry .
JOURNAL OF MATERIALS CHEMISTRY, 2010, 20 (08) :1452-1456
[3]   Potassium Zinc Borohydrides Containing Triangular [Zn(BH4)3]- and Tetrahedral [Zn(BH4)xCl4-x]2- Anions [J].
Cerny, Radovan ;
Ravnsbaek, Dorthe B. ;
Schouwink, Pascal ;
Filinchuk, Yaroslav ;
Penin, Nicolas ;
Teyssier, Jeremie ;
Smrcok, L'ubomir ;
Jensen, Torben R. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (01) :1563-1571
[4]   AZn2(BH4)5 (A = Li, Na) and NaZn(BH4)3: Structural Studies [J].
Cerny, Radovan ;
Kim, Ki Chul ;
Penin, Nicolas ;
D'Anna, Vincenza ;
Hagemann, Hans ;
Sholl, David S. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (44) :19127-19133
[5]   ZINC, HUMAN-DISEASES AND AGING [J].
FABRIS, N ;
MOCCHEGIANI, E .
AGING-CLINICAL AND EXPERIMENTAL RESEARCH, 1995, 7 (02) :77-93
[6]   Zinc and Regulation of Inflammatory Cytokines: Implications for Cardiometabolic Disease [J].
Foster, Meika ;
Samman, Samir .
NUTRIENTS, 2012, 4 (07) :676-694
[7]   NMR Study of Molecular Dynamics in Complex Metal Borohydride LiZn2(BH4)5 [J].
Gradisek, Anton ;
Ravnsbaek, Dorthe B. ;
Vrtnik, Stanislav ;
Kocjan, Andraz ;
Luznik, Janez ;
Apih, Tomaz ;
Jensen, Torben R. ;
Skripov, Alexander V. ;
Dolinsek, Janez .
JOURNAL OF PHYSICAL CHEMISTRY C, 2013, 117 (41) :21139-21147
[8]   Label-Free Colorimetric Detection of Cadmium Ions in Rice Samples Using Gold Nanoparticles [J].
Guo, Yongming ;
Zhang, Yi ;
Shao, Huawu ;
Wang, Zhuo ;
Wang, Xuefei ;
Jiang, Xingyu .
ANALYTICAL CHEMISTRY, 2014, 86 (17) :8530-8534
[9]  
Gupta V.K., 2011, ELECTROANAL, V13, P1036
[10]   Aluminum(III) selective potentiometric sensor based on morin in poly(vinyl chloride) matrix [J].
Gupta, Vinod K. ;
Jain, Ajay K. ;
Maheshwari, Gaurav .
TALANTA, 2007, 72 (04) :1469-1473