Accuracy of computational hemodynamics in complex arterial geometries reconstructed from magnetic resonance imaging

被引:126
作者
Moore, JA
Steinman, DA
Holdsworth, DW
Ethier, CR
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Univ Toronto, Inst Biomed Engn, Toronto, ON M5S 3G8, Canada
[3] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[4] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[5] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, London, ON, Canada
关键词
blood flow; magnetic resonance imaging; numerical flow modeling; carotid artery; three-dimensional; wall shear stress; atherosclerosis;
D O I
10.1114/1.163
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: Combining computational blood flow modeling with three-dimensional medical imaging provides a new approach for studying links between hemodynamic factors and arterial disease. Although this provides patient-specific hemodynamic information, it is subject to several potential errors. This study quantifies some of these errors and identifies optimal reconstruction methodologies. Methods: A carotid artery bifurcation phantom of known geometry was imaged using a commercial magnetic resonance (MR) imager. Three-dimensional models were reconstructed from the images using several reconstruction techniques, and steady and unsteady blood flow simulations were performed. The carotid bifurcation from a healthy, human volunteer was then imaged in vivo, and geometric models were reconstructed. Results: Reconstructed models of the phantom showed good agreement with the gold standard geometry, with a mean error of approximately 15% between the computed wall shear stress fields. Reconstructed models of the in vivo carotid bifurcation were unacceptably noisy, unless lumenal profile smoothing and approximating surface splines were used. Conclusions: All reconstruction methods gave acceptable results for the phantom model, but in vivo models appear to require smoothing. If proper attention is paid to smoothing and geometric fidelity issues, models reconstructed from MR images appear to be suitable for use in computational studies of in vivo hemodynamics. (C) 1999 Biomedical Engineering Society. [S0090-6964(99)01401-0].
引用
收藏
页码:32 / 41
页数:10
相关论文
共 13 条
  • [1] [Anonymous], 3 DIMENSIONAL BIOMED
  • [2] ETHIER CR, IN PRESS HEMODYNAMIC
  • [3] EFFECTS OF ARTERIAL COMPLIANCE AND NON-NEWTONIAN RHEOLOGY ON CORRELATIONS BETWEEN INTIMAL THICKNESS AND WALL SHEAR
    FRIEDMAN, MH
    BARGERON, CB
    DUNCAN, DD
    HUTCHINS, GM
    MARK, FF
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03): : 317 - 320
  • [4] HOLDSWORTH DW, 1995, RADIOLOGY, V197, P451
  • [5] Hughet RJ, 1996, J STRENGTH COND RES, V10, P224
  • [6] PULSATILE FLOW AND ATHEROSCLEROSIS IN THE HUMAN CAROTID BIFURCATION - POSITIVE CORRELATION BETWEEN PLAQUE LOCATION AND LOW AND OSCILLATING SHEAR-STRESS
    KU, DN
    GIDDENS, DP
    ZARINS, CK
    GLAGOV, S
    [J]. ARTERIOSCLEROSIS, 1985, 5 (03): : 293 - 302
  • [7] Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects
    Milner, JS
    Moore, JA
    Rutt, BK
    Steinman, DA
    [J]. JOURNAL OF VASCULAR SURGERY, 1998, 28 (01) : 143 - 156
  • [8] Moore JA, 1998, J BIOMECH, V31, P179, DOI 10.1016/S0021-9290(97)00125-5
  • [9] MOORE JA, 1998, THESIS U TORONTO
  • [10] PULSATILE FLOW VISUALIZATION IN THE ABDOMINAL-AORTA UNDER DIFFERING PHYSIOLOGICAL CONDITIONS - IMPLICATIONS FOR INCREASED SUSCEPTIBILITY TO ATHEROSCLEROSIS
    MOORE, JE
    KU, DN
    ZARINS, CK
    GLAGOV, S
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03): : 391 - 397