ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY

被引:15
作者
Silva, E. H. [1 ,2 ,3 ,4 ]
Knezevic, Z. [5 ]
Struelens, L. [1 ]
Covens, P. [2 ,3 ,6 ]
Ueno, S. [7 ]
Vanhavere, F. [1 ]
Buls, N. [2 ,3 ,8 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, Boeretang 200, B-2400 Mol, Belgium
[2] VUB, LABO, Laarbeeklaan 103, B-1090 Brussels, Belgium
[3] BEFY, Laarbeeklaan 103, B-1090 Brussels, Belgium
[4] Minist Educ Brazil, CAPES Fdn, BR-70040020 Brasilia, DF, Brazil
[5] Rudjer Boskovic Inst, Bijenicka 54, Zagreb 10000, Croatia
[6] Dept Radiat Protect VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium
[7] Chiyoda Technol Corp, Oarai Res Ctr, 3681 Naritacho, Oarai, Ibaraki 3111313, Japan
[8] UZ Brussel, Dept Radiol, Laarbeeklaan 101, B-1090 Brussels, Belgium
关键词
CONVERSION COEFFICIENTS; DOSE-EQUIVALENT; AIR KERMA; RADIATION; PHANTOM; PHOTON; H-P(3);
D O I
10.1093/rpd/ncw104
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radio-photoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0 up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK center dot CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruder Boskovic Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to H-p(3), although some improvements may be necessary.
引用
收藏
页码:208 / 212
页数:5
相关论文
共 18 条
  • [1] AGC Techno Glass, 2012, GLASS DOS GD 300 SER
  • [2] Air kerma to Hp(3) conversion coefficients for a new cylinder phantom for photon reference radiation qualities
    Behrens, R.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 151 (03) : 450 - 455
  • [3] AIR KERMA TO DOSE EQUIVALENT CONVERSION COEFFICIENTS NOT INCLUDED IN ISO 4037-3
    Behrens, Rolf
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 373 - 379
  • [4] The new EYE-D™ dosemeter for measurements of HP(3) for medical staff
    Bilski, P.
    Bordy, J-M.
    Daures, J.
    Denoziere, M.
    Fantuzzi, E.
    Ferrari, P.
    Gualdrini, G.
    Kopec, M.
    Mariotti, F.
    Monteventi, F.
    Wach, S.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1239 - 1242
  • [5] EYE DOSIMETRY IN INTERVENTIONAL RADIOLOGY AND CARDIOLOGY: CURRENT CHALLENGES AND PRACTICAL CONSIDERATIONS
    Ciraj-Bjelac, O.
    Rehani, M. M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 329 - 337
  • [6] FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS
    Clairand, I.
    Ginjaume, M.
    Vanhavere, F.
    Carinou, E.
    Daures, J.
    Denoziere, M.
    Silva, E. H.
    Roig, M.
    Principi, S.
    Van Rycheghem, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 21 - 26
  • [7] Use of active personal dosemeters in interventional radiology and cardiology: Tests in laboratory conditions and recommendations - ORAMED project
    Clairand, I.
    Bordy, J. -M.
    Carinou, E.
    Daures, J.
    Debroas, J.
    Denoziere, M.
    Donadille, L.
    Ginjaume, M.
    Itie, C.
    Koukorava, C.
    Krim, S.
    Lebacq, A. -L.
    Martin, P.
    Struelens, L.
    Sans-Merce, M.
    Vanhavere, F.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1252 - 1257
  • [8] A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists
    Farah, J.
    Struelens, L.
    Dabin, J.
    Koukorava, C.
    Donadille, L.
    Jacob, S.
    Schnelzer, M.
    Auvinen, A.
    Vanhavere, F.
    Clairand, I.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (04) : 561 - 569
  • [9] Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays
    Gamboa-DeBuen, I
    Buenfil, AE
    Ruiz, CG
    Rodriguez-Villafuerte, M
    Flores, A
    Brandan, ME
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) : 2073 - 2083
  • [10] A new cylindrical phantom for eye lens dosimetry development
    Gualdrini, G.
    Mariotti, F.
    Wach, S.
    Bilski, P.
    Denoziere, M.
    Daures, J.
    Bordy, J. -M.
    Ferrari, P.
    Monteventi, F.
    Fantuzzi, E.
    Vanhavere, F.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1231 - 1234