Reduction thermal damage to cortical bone using ultrasonically-assisted drilling

被引:12
作者
Zheng, Qingchun [1 ]
Xia, Lei [1 ]
Zhang, Xu [1 ]
Zhang, Chunqiu [1 ]
Hu, Yahui [1 ]
机构
[1] Tianjin Univ Technol, Tianjin Key Lab Adv Mechatron Syst Design & Intel, Tianjin 300384, Peoples R China
基金
中国国家自然科学基金;
关键词
Bone drilling; temperature; ultrasonically-assisted drilling; thermal damage; predictive model; FINITE-ELEMENT; TEMPERATURE RISE; CUTTING FORCES; HOLE QUALITY; TWIST DRILL; PARAMETERS; HEAT; INJURY; SIMULATIONS;
D O I
10.3233/THC-181245
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Thermal damage induced by bone drilling is a common problem during surgical procedures. A recent and promising method utilizes high-frequency low-amplitude vibration in the feed direction during drilling and has the potential to reduce drilling temperature, minimizing the risk of thermal damage. OBJECTIVE: The purpose of this study was to investigate the effects of ultrasonically-assisted drilling (UAD) on cortical bone temperature. METHODS: A series of experiments was conducted to compare the cortical bone temperature during UAD with that during conventional drilling (CD). A thermo-mechanical 3D finite element model (FEM) of UAD was developed, using ABAQUS, to help understand temperature changes during drilling of cortical bone. The numerical simulation results of FEM showed good agreement with the experimental data. Subsequently, a predictive model was developed for bone temperature during drilling, using multiple regression analysis based on the results from numerical simulation. RESULTS: The results showed drill diameter had the greatest influence on drilling temperature, followed by the rotational speed of the drill. Additionally, the variation of vibration frequency had more influence on the drilling temperature than did the amplitude. CONCLUSIONS: Ultrasonically-assisted drilling is helpful to lower drilling temperature to reduce the thermal damage of bone tissue.
引用
收藏
页码:843 / 856
页数:14
相关论文
共 39 条
[1]   Analysis of temperature in conventional and ultrasonically-assisted drilling of cortical bone with infrared thermography [J].
Alam, K. ;
Silberschmidt, Vadim V. .
TECHNOLOGY AND HEALTH CARE, 2014, 22 (02) :243-252
[2]  
Alam K., 2010, International Journal of Experimental and Computational Biomechanics, V1, P236, DOI 10.1504/IJECB.2010.035259
[3]   Analysis of Forces and Temperatures in Conventional and Ultrasonically-assisted Cutting of Bone [J].
Alam, K. ;
Ghafoor, A. ;
Silberschmidt, V. V. .
MODELLING OF MACHINING OPERATIONS, 2011, 223 :247-+
[4]   Finite element analysis of forces of plane cutting of cortical bone [J].
Alam, K. ;
Mitrofanov, A. V. ;
Silberschmidt, V. V. .
COMPUTATIONAL MATERIALS SCIENCE, 2009, 46 (03) :738-743
[5]  
Alam K, 2009, J PHYS C SERIES, V181, P1742
[6]  
Alam K., 2009, EXPT NUMERICAL ANAL
[7]   Experimental measurements of temperatures in ultrasonically assisted drilling of cortical bone [J].
Alam, Khurshid ;
Hassan, Edris ;
Bahadur, Issam .
BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2015, 29 (04) :753-757
[8]   Vibration Drilling of Al2024-T6 [J].
Amini, S. ;
Paktinat, H. ;
Barani, A. ;
Tehran, A. Fadaei .
MATERIALS AND MANUFACTURING PROCESSES, 2013, 28 (04) :476-480
[9]   Cortical bone drilling and thermal osteonecrosis [J].
Augustin, Goran ;
Zigman, Tomislav ;
Davila, Slavko ;
Udilljak, Toma ;
Staroveski, Tomislav ;
Brezak, Danko ;
Babic, Slaven .
CLINICAL BIOMECHANICS, 2012, 27 (04) :313-325
[10]   Finite element and experimental investigation of temperature changes on a twist drill in sequential dry drilling [J].
Bagci, E ;
Ozcelik, B .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2006, 28 (7-8) :680-687