Salvaging Pull-Out Strength in a Previously Stripped Screw Site: A Comparison of Three Rescue Techniques

被引:6
作者
Addevico, Francesco [1 ]
Solitro, Giovanni F. [2 ]
Morandi, Massimo Max [2 ]
机构
[1] Osped Niguarda Ca Granda, Dept Orthoped & Traumatol, I-20162 Milan, Italy
[2] Louisiana State Univ Hlth Shreveport, Dept Orthopaed Surg, Shreveport, LA 71103 USA
关键词
screw; stripping; rescue; thread; CORTICAL BONE; FIXATION; INSERTION; FRACTURE; TORQUE;
D O I
10.3390/jfmk6030071
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Screw stripping during bone fixation is a common occurrence during operations that results in decreased holding capacity and bone healing. We aimed to evaluate the rescue of the stripped screw site using screws of different dimensions. Five screw configurations were tested on cadaveric specimens for pull-out strength (POS). The configurations included a control screw tightened without stripping, a configuration voluntarily stripped and left in place, and three more configurations in which the stripped screws were replaced by a different screw with either increased overall length, diameter, or thread length. Each configuration was tested five times, with each screw tested once. The POS of the control screw, measured to be 153.6 +/- 27 N, was higher than the POS measured after stripping and leaving the screw in place (57.1 +/- 18 N, p = 0.001). The replacement of the stripped screw resulted in a POS of 158.4 +/- 64 N for the screw of larger diameter, while the screws of the same diameter but increased length or those with extended thread length yielded POS values of 138.4 +/- 42 and 185.7 +/- 48 N, respectively. Screw stripping is a frequent intraoperative complication that, according to our findings, cannot be addressed by leaving the screw in place. The holding capacity of a stripped screw implanted in cancellous bone can successfully be restored with a different screw of either larger diameter, longer length, or extended thread length.
引用
收藏
页数:8
相关论文
共 31 条
[21]   Combination of hook plate and tibial pro-fibular screw fixation of osteoporotic fractures: A clinical evaluation of operative strategy [J].
Panchbhavi, VK ;
Mody, MG ;
Mason, WT .
FOOT & ANKLE INTERNATIONAL, 2005, 26 (07) :510-515
[22]   Salvaging the Pullout Strength of Stripped Screws in Osteoporotic Bone [J].
Pechon, Pierre H. M. ;
Mears, Simon C. ;
Langdale, Evan R. ;
Belkoff, Stephen M. .
GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2013, 4 (02) :50-57
[23]   Variability of the pullout strength of cancellous bone screws with cement augmentation [J].
Procter, P. ;
Bennani, P. ;
Brown, C. J. ;
Arnoldi, J. ;
Pioletti, D. P. ;
Larsson, S. .
CLINICAL BIOMECHANICS, 2015, 30 (05) :500-506
[24]   Constant mineralization density distribution in cancellous human bone [J].
Roschger, P ;
Gupta, HS ;
Berzanovich, A ;
Ittner, G ;
Dempster, DW ;
Fratzl, P ;
Cosman, F ;
Parisien, M ;
Lindsay, R ;
Nieves, JW ;
Klaushofer, K .
BONE, 2003, 32 (03) :316-323
[25]  
Sobhan MR, 2016, ARCH BONE JT SURG-AB, V4, P381
[26]  
Steeves M, 2005, CAN J SURG, V48, P207
[27]   Surgeon Perception of Cancellous Screw Fixation [J].
Stoesz, Michael J. ;
Gustafson, Peter A. ;
Patel, Bipinchandra V. ;
Jastifer, James R. ;
Chess, Joseph L. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (01) :E1-E7
[28]   Does Maximum Torque Mean Optimal Pullout Strength of Screws? [J].
Tankard, Sara E. ;
Mears, Simon C. ;
Marsland, Daniel ;
Langdale, Evan R. ;
Belkoff, Stephen M. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (04) :232-235
[29]   Mechanical Evaluation of a 4-mm Cancellous "Rescue" Screw in Osteoporotic Cortical Bone: A Cadaveric Study [J].
Wall, Simon J. ;
Soin, Sandeep P. ;
Knight, Trevor A. ;
Mears, Simon C. ;
Belkoff, Stephen M. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (06) :379-382
[30]   Real time monitoring of screw insertion using acoustic emission can predict screw stripping in human cancellous bone [J].
Wright, B. J. ;
Grigg, S. ;
Bergsaker, A. S. ;
Brattgjerd, J. E. ;
Steen, H. ;
Pullin, R. .
CLINICAL BIOMECHANICS, 2020, 76