Retinal and Corneal Changes Associated with Intraocular Silicone Oil Tamponade

被引:26
作者
Ferrara, Mariantonia [1 ]
Coco, Giulia [2 ,3 ]
Sorrentino, Tania [4 ]
Jasani, Kirti M. [1 ]
Moussa, George [1 ]
Morescalchi, Francesco [5 ,6 ]
Dhawahir-Scala, Felipe [1 ]
Semeraro, Francesco [5 ,6 ]
Steel, David H. W. [7 ,8 ]
Romano, Vito [5 ,6 ]
Romano, Mario R. [4 ,9 ]
机构
[1] Manchester Royal Eye Hosp, Oxford Rd, Manchester M13 9WL, Lancs, England
[2] Univ Roma Tor Vergata, Dept Clin Sci & Translat Med, I-00133 Rome, Italy
[3] Royal Liverpool Univ Hosp, Dept Corneal Dis, St Pauls Eye Unit, Liverpool L7 8XP, Merseyside, England
[4] Humanitas Univ, Dept Biomed Sci, I-20090 Pieve Emanuele, Italy
[5] Univ Brescia, Dept Med & Surg Specialties, Radiol Sci & Publ Hlth, Eye Clin, I-25121 Brescia, Italy
[6] ASST Civil Hosp Brescia, I-25123 Brescia, Italy
[7] Newcastle Univ, Biosci Inst, Catherine Cookson Bldg, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[8] Sunderland Eye Infirm, Queen Alexandra Rd, Sunderland SR2 9HP, England
[9] Humanitas Gavazzeni Castelli, Eye Ctr, I-24128 Bergamo, Italy
关键词
confocal microscopy; cornea; corneal endothelial cell count; optical coherence tomography; pars plana vitrectomy; retina; retinal layer segmentation; silicone oil; silicone oil emulsification; silicone oil-induced keratopathy; OPTICAL COHERENCE TOMOGRAPHY; NERVE-FIBER-LAYER; PARS-PLANA VITRECTOMY; UNEXPLAINED VISUAL-LOSS; ENDOTHELIAL-CELL DENSITY; DETACHMENT REPAIR; PERFLUOROCARBON LIQUIDS; PROLIFERATIVE VITREORETINOPATHY; MACULAR MICROSTRUCTURE; CONFOCAL MICROSCOPY;
D O I
10.3390/jcm11175234
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Silicone oils (SO) are used as long-term intraocular tamponades and have an irreplaceable role in vitreoretinal surgery. They can, however, be associated with multiple and potentially severe complications, involving different ocular tissues, in particular retina and cornea. Recent advances in ophthalmic imaging have allowed the precise characterization of retinal and corneal microstructural changes, at a subclinical level. This detailed analysis of SO-related retinal and corneal changes has improved our understanding of their pathogenesis and offer the potential for optimized monitoring and management of patients with SO-filled eyes. This review aims to provide clinicians and ophthalmic scientists with an updated and comprehensive overview of the corneal and retinal changes associated with SO tamponade.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Retinal sensitivity following intraocular silicone oil and gas tamponade for rhegmatogenous retinal detachment
    Scheerlinck, Laura M.
    Schellekens, Peter A.
    Liem, Albert T.
    Steijns, Daan
    van Leeuwen, Redmer
    ACTA OPHTHALMOLOGICA, 2018, 96 (06) : 641 - 647
  • [2] Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade
    Teke, Mehmet Yasin
    Elgin, Ufuk
    Ozdal, Pinar
    Ozturk, Faruk
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2012, 42 (03): : 238 - 240
  • [3] Retinal Nerve Fiber Layer Changes after Intraocular Silicone Oil Tamponade in Rhegmatogenous Retinal Detachment
    Chikmah, Fitri Annur
    Ichsan, Andi Muhammad
    Islam, Itzar Chaidir
    Hendarto, Joko
    Muhiddin, Habibah Setyawati
    Budu
    VISION, 2023, 7 (01)
  • [4] Comparison of Retinal Changes Following Silicone Oil and Perfluoropropane Gas Tamponade for Proliferative Diabetic Retinopathy Patients
    Wang, Tan
    Wang, Erqian
    Chen, Huan
    Li, Ningning
    Min, Hanyi
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [5] Corneal endothelial changes induced by pars plana vitrectomy with silicone oil tamponade for retinal detachment
    Coman , Corina Cristina
    Malita, Daniel
    Stanca, Simona
    Patoni , Stella Ioana
    Musat, Ovidiu
    Negru, Serban
    Feier, Horea
    Karancsi, Olimpiu Ladislau
    Rosca, Cosmin
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2021, 22 (03)
  • [6] Effect of Duration of Silicone Oil Tamponade on Retinal Structure after Rhegmatogenous Retinal Detachment Surgery
    Dubroux, Chloe
    Salleron, Julia
    Angioi-Duprez, Karine
    Berrod, Jean-Paul
    Conart, Jean-Baptiste
    OPHTHALMOLOGICA, 2022, 245 (02) : 144 - 151
  • [7] Computational Fluid Dynamics of Intraocular Silicone Oil Tamponade
    Rossi, Tommaso
    Querzoli, Giorgio
    Badas, Maria Grazia
    Angius, Federico
    Telani, Serena
    Ripandelli, Guido
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (08):
  • [8] Retinal Layers Measurements following Silicone Oil Tamponade for Retinal Detachment Surgery
    Jurisic, Darija
    Geber, Mia Zoric
    Cavar, Ivan
    Utrobicic, Dobrila Karlica
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (05) : 711 - 718
  • [9] Peripapillary changes after vitrectomy and silicone oil tamponade for rhegmatogenous retinal detachment
    Jiang, Jian
    Li, Rui
    Zhou, Jin-Xiu
    Li, Rui-Mei
    Wang, Rui-Hua
    Wang, Xia-Ping
    Dou, Ran
    Jia, Ya-Ding
    Li, Shuang-Nong
    Chen, Song
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (12) : 3579 - 3583
  • [10] 1000 cSt silicone oil vs heavy silicone oil as intraocular tamponade in retinal detachment associated to myopic macular hole
    Mete, Maurizio
    Parolini, Barbara
    Maggio, Emilia
    Pertile, Grazia
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (06) : 821 - 826