Comparison of nitrogen elimination rates of different constructed wetland designs

被引:24
作者
Canga, Eriona [2 ]
Dal Santo, Sara [2 ]
Pressl, Alexander [1 ]
Borin, Maurizio [2 ]
Langergraber, Guenter [1 ]
机构
[1] Univ Nat Resources & Life Sci, Inst Sanit Engn & Water Pollut Control, Vienna BOKU, A-1190 Vienna, Austria
[2] Univ Padua, Dipartimento Agron Ambientale & Prod Vegetali, I-35020 Legnaro, PD, Italy
关键词
constructed wetland design; nitrogen removal; two-stage vertical flow; WASTE-WATER TREATMENT; VERTICAL-FLOW; REMOVAL EFFICIENCY; PERFORMANCE; LOAD;
D O I
10.2166/wst.2011.433
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper the nitrogen elimination rates of different constructed wetland (CW) designs reported in literature are compared with those obtained for outdoor and indoor 2-stage vertical flow (VF) systems. The outdoor system is located about 150 km west of Vienna. Both stages are planted with Phragmites australis and the system has been operated for 4 years continuously. During this period the average value of the nitrogen elimination rate was 3.30 g N m(-2) d(-1). The indoor system comprises three parallel operated 2-stage VF systems and is located in the technical lab hall at BOKU University. The design of the indoor system resembles the outdoor system. However, there are a few differences: (1) the indoor systems are not planted, and (2) different filter media have been used for the main layer of the first stages. With the indoor system the highest nitrogen elimination rate achieved was 2.24 g N m(-2) d(-1) for the system with zeolite and impounded drainage layer. Similar results have been found in France for treating raw wastewater with VF and horizontal flow (HF) beds in series with nitrogen elimination rates of 1.89 and 2.82 g N m(-2) d(-1) for differently designed HF beds. The highest nitrogen elimination rates of 15.9 g N m(-2) d(-1) reported were for pilot-scale VF CWs treating high-strength synthetic wastewater (total nitrogen of 305 mg L(-1) in the influent) in Thailand. It has been shown that the outdoor two-stage VF CW system has one of the highest nitrogen elimination rates of CWs treating domestic wastewater.
引用
收藏
页码:1122 / 1129
页数:8
相关论文
共 24 条
  • [1] Horizontal subsurface flow gravel bed constructed wetland with Phragmites karka in central India
    Billore, SK
    Singh, N
    Sharma, JK
    Dass, P
    Nelson, RM
    [J]. WATER SCIENCE AND TECHNOLOGY, 1999, 40 (03) : 163 - 171
  • [2] CANGA E, 2010, THESIS U NATURAL RES
  • [3] Cerezo RG, 2001, ECOL ENG, V16, P501
  • [4] Dal Santo S., 2010, P 12 IWA SPEC GROUP, P263
  • [5] Kadlec R.H., 2009, Treatment Wetlands: Theory and Implementation, V2nd
  • [6] Treatment of high-strength wastewater in tropical vertical flow constructed wetlands planted with Typha angustifolia and Cyperus involucratus
    Kantawanichkul, Suwasa
    Kladprasert, Supreeya
    Brix, Hans
    [J]. ECOLOGICAL ENGINEERING, 2009, 35 (02) : 238 - 247
  • [7] Two strategies for advanced nitrogen elimination in vertical flow constructed wetlands
    Laber, J
    Perfler, R
    Haberl, R
    [J]. WATER SCIENCE AND TECHNOLOGY, 1997, 35 (05) : 71 - 77
  • [8] Removal efficiency of subsurface vertical flow constructed wetlands for different organic loads
    Langergraber, G.
    Prandtstetten, C.
    Pressl, A.
    Rohrhofer, R.
    Haberl, R.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2007, 56 (03) : 75 - 84
  • [9] A two-stage subsurface vertical flow constructed wetland for high-rate nitrogen removal
    Langergraber, Guenter
    Leroch, Klaus
    Pressl, Alexander
    Rohrhofer, Roland
    Haberl, Raimund
    [J]. WATER SCIENCE AND TECHNOLOGY, 2008, 57 (12) : 1881 - 1887
  • [10] Long-term behaviour of a two-stage CW system regarding nitrogen removal
    Langergraber, Guenter
    Pressl, Alexander
    Leroch, Klaus
    Rohrhofer, Roland
    Haberl, Raimund
    [J]. WATER SCIENCE AND TECHNOLOGY, 2011, 64 (05) : 1137 - 1141