Application of cation-exchange solid-phase extraction for the analysis of amino alcohols from water and human plasma for verification of Chemical Weapons Convention

被引:37
作者
Kanaujia, Pankaj K. [1 ]
Tak, Vijay [1 ]
Pardasani, Deepak [1 ]
Gupta, A. K. [1 ]
Dubey, D. K. [1 ]
机构
[1] Def Res & Dev Estab, Vertox Lab, Gwalior 474002, India
关键词
solid-phase extraction; cation-exchange cartridges; chemical warfare agents; amino alcohols; human plasma; chemicals weapons convention;
D O I
10.1016/j.chroma.2008.01.080
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of nitrogen containing amino alcohols, which are the precursors and degradation products of nitrogen mustards and nerve agent VX, constitutes an important aspect for verifying the compliance to the CWC (Chemical Weapons Convention). This work devotes on the development of solid-phase extraction method using silica- and polymer-based SCX (strong cation-exchange) and MCX (mixed-mode strong cation-exchange) cartridges for N,N-dialkylaminoethane-2-ols and alkyl NN-diethanolamines, from water. The extracted analytes were analyzed by GC-MS (gas chromatography-mass spectrometry) in the full scan and selected ion monitoring modes. The extraction efficiencies of SCX and MCX cartridges were compared, and results revealed that SCX performed better. Extraction parameters, such as loading capacity, extraction solvent, its volume, and washing solvent were optimized. Best recoveries were obtained using 2 mL methanol containing 10% NH4OH and limits of detection could be achieved up to 5 x 10(-3) mu g mL(-1) in the selected ion monitoring mode and 0.01 mu g mL(-1) in full scan mode. The method was successfully employed for the detection and identification of amino alcohol present in water sample sent by Organization for Prohibition of Chemical Weapons (OPCW) in the official proficiency tests. The method was also applied to extract the analytes from human plasma. The SCX cartridge showed good recoveries of amino alcohols from human plasma after protein precipitation. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:167 / 177
页数:11
相关论文
共 38 条
[1]  
[Anonymous], 1997, CONV PROH DEV PROD S
[2]   Derivatisation reactions in the chromatographic analysis of chemical warfare agents and their degradation products [J].
Black, RM ;
Muir, B .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :253-281
[3]   Screening of nitrogen mustards and their degradation products in water and decontamination solution by liquid chromatography-mass spectrometry [J].
Chua, HC ;
Lee, HS ;
Sng, MT .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :214-223
[4]   Hollow fiber-mediated liquid-phase microextraction of chemical warfare agents from water [J].
Dubey, DK ;
Pardasani, D ;
Gupta, AK ;
Palit, M ;
Kanaujia, PK ;
Tak, V .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1107 (1-2) :29-35
[5]   On-matrix derivatisation-extraction of precursors of nitrogen- and sulfur-mustards for verification of chemical weapons convention [J].
Dubey, DK ;
Pardasani, D ;
Palit, M ;
Gupta, AK ;
Jain, R .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1076 (1-2) :27-33
[6]  
Hartman WW, 1934, ORG SYNTH, V14, P28
[7]  
Hendrikse J, 2005, CHEMICAL WEAPONS CONVENTION CHEMICALS ANALYSIS: SAMPLE COLLECTION, PREPARATION AND ANALYTICAL METHODS, P89
[8]  
HOLLEMAN AF, 1995, INORG CHEM, P1078
[9]   Identification of chemicals related to the chemical weapons convention during an interlaboratory proficiency test [J].
Hooijschuur, EWJ ;
Hulst, AG ;
de Jong, AL ;
de Reuver, LP ;
van Krimpen, SH ;
van Baar, BLM ;
Wils, ERJ ;
Kientz, CE ;
Brinkman, UAT .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (02) :116-130
[10]   Mixed-mode solid-phase extraction procedures for the determination of MDMA and metabolites in urine using LGMS, LC-UV, or GC-NPD [J].
Jenkins, KM ;
Young, MS ;
Mallet, CR ;
Elian, AA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2004, 28 (01) :50-58