Analysis of electrical resistance tomography measurements obtained on a bubble column

被引:42
作者
Fransolet, E [1 ]
Crine, M [1 ]
L'Homme, G [1 ]
Toye, D [1 ]
Marchot, P [1 ]
机构
[1] Univ Liege, Lab Genie Chem, B-4000 Liege, Belgium
关键词
gas hold-up; bubble column; electrical resistance tomography;
D O I
10.1088/0957-0233/12/8/310
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Measurements of gas hold-up obtained by using pressure transducers and an optical probe are compared with those obtained by an electrical resistance tomography method. The use of a neural network, the input of which is the electrical measurements, can lead to quantitative results for the gas hold-up distribution. An interesting qualitative diagnosis of the sparger functioning is observed from reconstructed images.
引用
收藏
页码:1055 / 1060
页数:6
相关论文
共 13 条
[1]   Measurement and analysis of flows in a gas-liquid column reactor [J].
Bennett, MA ;
West, RM ;
Luke, SP ;
Jia, X ;
Williams, RA .
CHEMICAL ENGINEERING SCIENCE, 1999, 54 (21) :5003-5012
[2]  
BIDIN AR, 1994, P 3 ECAPT C EUR CONC, P203
[3]  
DEKWER WD, 1992, BUBBLE COLUMN REACTO
[4]   Electrical resistance tomography for process applications [J].
Dickin, F ;
Wang, M .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (03) :247-260
[5]   Imaging stirred-vessel macromixing using electrical resistance tomography [J].
Holden, PJ ;
Wang, M ;
Mann, R ;
Dickin, FJ ;
Edwards, RB .
AICHE JOURNAL, 1998, 44 (04) :780-790
[6]   Gas-holdup measurements in bubble columns using computed tomography [J].
Kumar, SB ;
Moslemian, D ;
Dudukovic, MP .
AICHE JOURNAL, 1997, 43 (06) :1414-1425
[7]  
NOORALAHIYAN AY, 1994, P EUR CONC ACT PROC, P266
[8]  
NOORALAHIYAN AY, 1995, P EUR CONC ACT PROC, P420
[9]  
SUN TD, 1999, P 1 WORLD C IND PROC, P174
[10]   Measurement of gas hold-up profiles by gamma ray tomography: Effect of sparger design and height of dispersion in bubble columns [J].
Veera, UP ;
Joshi, JB .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 1999, 77 (A4) :303-317