DETECTION AND PATHOLOGIC EVALUATION OF SENTINEL LYMPH NODES IN THE VX2 TUMOR MODEL USING A NOVEL ULTRASOUND/NEAR-INFRARED DUAL-MODALITY CONTRAST AGENT

被引:4
作者
Qu, Enze [1 ]
Dai, Zhifei [2 ]
Liang, Xiaolong [2 ]
Qian, Yajun [3 ]
Wang, Shumin [3 ]
Ke, Hengte [2 ]
Wang, Jinrui [3 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 3, Dept Ultrasound, Guangzhou 510275, Guangdong, Peoples R China
[2] Peking Univ, Inst Technol, Dept Life Sci, Beijing 100191, Peoples R China
[3] Peking Univ, Hosp 3, Dept Ultrasound, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Sentinel lymph node; Contrast microbubbles; Fluorescence imaging; Ultrasound; ISOSULFAN BLUE-DYE; BREAST-CANCER; AXILLARY DISSECTION; BIOPSY; MELANOMA; TRIAL; LUNG;
D O I
10.1016/j.ultrasmedbio.2015.03.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study was conducted with the aim of developing a microbubble agent for near-infrared (NIR) fluorescence and ultrasound dual-modality contrast microbubbles applicable to imaging of sentinel lymph nodes in the VX2 rabbit tumor model. Specific ligands of phosphatidylserine (PS) and Cy7 NIR fluorescent dyes with long emission wavelengths (750-900 nm) were conjugated to the surface of ultrasound contrast microbubbles (MBs), termed Cy7 PS MBs. Ultrasound lymphography and NIR fluorescence imaging were performed using subcutaneous injection of Cy7 PS MBs to visualize the sentinel lymph node. Sentinel lymph node detection rates using the patent blue method, ultrasound lymphography and NIR fluorescence imaging were 95%, 79% and 95%, respectively, and sensitivity was 87%, 74% and 92%, respectively. With 2-D ultrasound, the diagnostic sensitivity for detection of sentinel lymph node metastases was 60% and the specificity was 74%, whereas Cy7 PS MB-enhanced ultrasound had a sensitivity of 80% and a specificity of 87%. The results indicate that dual-modality Cy7 PS MBs combined with ultrasound lymphography and NIR fluorescence may be useful in the detection of normal and metastasized sentinel lymph nodes. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1905 / 1912
页数:8
相关论文
共 16 条
  • [11] Intraoperative sentinel node identification in early stage cervical cancer using a combination of radiolabeled albumin injection and isosulfan blue dye injection
    Martínez-Palones, JM
    Gil-Moreno, A
    Pérez-Benavente, MA
    Roca, I
    Xercavins, J
    [J]. GYNECOLOGIC ONCOLOGY, 2004, 92 (03) : 845 - 850
  • [12] Intraoperative sentinel lymph node mapping of the lung using near-infrared fluorescent quantum dots
    Soltesz, EG
    Kim, S
    Laurence, RG
    DeGrand, AM
    Parungo, CP
    Dor, DM
    Cohn, LH
    Bawendi, MG
    Frangioni, JV
    Mihaljevic, T
    [J]. ANNALS OF THORACIC SURGERY, 2005, 79 (01) : 269 - 277
  • [13] Multicenter trial of sentinel node biopsy for breast cancer using both technetium sulfur colloid and isosulfan blue dye
    Tafra, L
    Lannin, DR
    Swanson, MS
    Van Eyk, JJ
    Verbanac, KM
    Chua, AN
    Ng, PC
    Edwards, MS
    Halliday, BE
    Henry, CA
    Sommers, LM
    Carman, CM
    Molin, MR
    Yurko, JE
    Perry, RR
    Williams, R
    [J]. ANNALS OF SURGERY, 2001, 233 (01) : 51 - 59
  • [14] The FLARE™ Intraoperative Near-Infrared Fluorescence Imaging System: A First-in-Human Clinical Trial in Breast Cancer Sentinel Lymph Node Mapping
    Troyan, Susan L.
    Kianzad, Vida
    Gibbs-Strauss, Summer L.
    Gioux, Sylvain
    Matsui, Aya
    Oketokoun, Rafiou
    Ngo, Long
    Khamene, Ali
    Azar, Fred
    Frangioni, John V.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2009, 16 (10) : 2943 - 2952
  • [15] Sentinel-node biopsy to avoid axillary dissection in breast cancer with clinically negative lymph-nodes
    Veronesi, U
    Paganelli, G
    Galimberti, V
    Viale, G
    Zurrida, S
    Bedoni, M
    Costa, A
    deCicco, C
    Geraghty, JG
    Luini, A
    Sacchini, V
    Veronesi, P
    [J]. LANCET, 1997, 349 (9069) : 1864 - 1867
  • [16] The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging
    Xing, Zhanwen
    Wang, Jinrui
    Ke, Hengte
    Zhao, Bo
    Yue, Xiuli
    Dai, Zhifei
    Liu, Jibin
    [J]. NANOTECHNOLOGY, 2010, 21 (14)