Near real-time detection of Cryptosporidium parvum oocyst by IgM-functionalized piezoelectric-excited millimeter-sized cantilever biosensor

被引:42
作者
Campbell, Gossett A. [1 ,2 ]
Mutharasan, Raj
机构
[1] Drexel Univ, Dept Biol & Chem Engn, Philadelphia, PA 19104 USA
[2] GlaxoSmithKline, King Of Prussia, PA 19406 USA
关键词
IgM; flow; resonant frequency; detection limit;
D O I
10.1016/j.bios.2007.10.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Piezoelectric-excited millimeter-sized cantilever (PEMC) biosensors were fabricated and functionalized with immunoglobulin M (IgM) for the detection of Cryptosporidium parvum oocyst in a flow configuration at 1 mL/min. The detection of 100, 1000, and 10,000 oocysts/mL was achieved with a positive sensor response in less than 1 min. Bovine serum albumin (BSA) was used as a blocking agent in each experiment and was shown to eliminate non-specific binding. The sensor's resonance frequency response correlates with C. parvum oocyst concentration logarithmically. The oocyst attachment rate was found to increase by an order of magnitude in increasing concentration from 100 to 10,000 oocysts/mL. The significance of these results is that IgM-functionalized PEMC sensors are highly selective and sensitive to C. parvum oocyst and therefore, have the potential to accurately identify and quantify C. parvum oocyst in drinking water. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1039 / 1045
页数:7
相关论文
共 29 条
[1]   Apical organelles of Apicomplexa: biology and isolation by subcellular fractionation [J].
Blackman, MJ ;
Bannister, LH .
MOLECULAR AND BIOCHEMICAL PARASITOLOGY, 2001, 117 (01) :11-25
[2]   Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300 spores/mL [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (09) :1684-1692
[3]   Monitoring of the self-assembled monolayer of 1-hexadecanethiol on a gold surface at nanomolar concentration using a piezo-excited millimeter-sized cantilever sensor [J].
Campbell, GA ;
Mutharasan, R .
LANGMUIR, 2005, 21 (25) :11568-11573
[4]   Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :462-473
[5]   A method of measuring Escherichia coli O157:H7 at 1 cell/mL in 1 liter sample using antibody functionalized piezoelectric-excited millimeter-sized cantilever sensor [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (05) :1668-1674
[6]   Detect of Escherichia coli O157:H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors [J].
Campbell, Gossett A. ;
Uknalis, Joe ;
Tu, Shu-I ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1296-1302
[7]   Method of Measuring Bacillus anthracis Spores in the Presence of Copious Amounts of Bacillus thuringiensis and Bacillus cereus [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
ANALYTICAL CHEMISTRY, 2007, 79 (03) :1145-1152
[8]   Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (01) :78-85
[9]   PEMC sensor's mass change sensitivity is 20 pg/Hz under liquid immersion [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (01) :35-41
[10]   Comparison of most probable number-PCR and most probable number-foci detection method for quantifying infectious Cryptosporidium parvum oocysts in environmental samples [J].
Carey, Christine M. ;
Lee, Hung ;
Trevors, Jack T. .
JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 67 (02) :363-372