Pitfalls and complications with locking plate for proximal humerus fracture

被引:198
|
作者
Clavert, Philippe [1 ]
Adam, Philippe [1 ]
Bevort, Adrien [1 ]
Bonnomet, Francois [1 ]
Kempf, Jean-Francois [1 ]
机构
[1] CHU Strasbourg, CCOM, Shoulder & Elbow Serv, F-67400 Illkirch Graffenstaden, France
关键词
Shoulder; proximal humerus fracture; complication; locking plate; OPEN REDUCTION; INTERNAL-FIXATION; LOCKED PLATE; TRAUMA CARE; HEMIARTHROPLASTY; MULTICENTER; SHOULDER;
D O I
10.1016/j.jse.2009.09.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The aim of this study was to identify specific complications of locking plate fixation of proximal humerus fractures. Patients and Methods: Seventy-threee adult patients with a displaced 3- (24%) or 4-part (76%) fracture of the proximal humerus were treated over a period of 2 years under the supervision of a trauma surgeon. Fourty-four patients came back for a clinical and radiographic examinations at least 18 months after the trauma; the others were evaluated at,6 weeks and 3 and 6 months. Results: Out of the 73 patients (64.4% females, mean age of 65), 11 patients needed a second surgery and 18 were lost for follow-up after 6 months. Mean final constant score was 62.3 points. The incidence of secondary displacement was 8.2%. Nonunion rate was 5.5%, affecting the constant score (P=.018). 16.4% of the patients developed a partial necrosis of the humeral head at the latest follow-up, which influenced on the constant score (P=.029). Quality of the reduction of the greater tuberosity influenced final results (P=.037). Screw cutout rate was 13.7%, with an influence to the constant score (P=.001). A too high plate positioning influenced the constant score (P=.002). Conclusion: Locked screw-plates provide more secure fixation of fractures, especially in weak bone. Complications rate remains high. Two complications are to be distinguished: 1) technical complications in plate positioning, length of the screws or secondary screw cutout strongly influence the final clinical result; and 2) specific complications related to this technology such as pseudarthrosis or plate fracture.
引用
收藏
页码:489 / 494
页数:6
相关论文
共 50 条
  • [21] Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?
    Kim, Beom-Soo
    Kim, Du-Han
    Choi, Jung-Hoon
    Choi, Byung-Chan
    Cho, Chul-Hyun
    MEDICINA-LITHUANIA, 2022, 58 (03):
  • [22] Functional Outcome and Complications in Management of Proximal Humerus Fractures Operated with Proximal Humerus Locking Plate
    George, P. K.
    Dasgupta, B.
    Bhaladhare, S. M.
    Reddy, B. P., V
    Jain, A.
    Jogani, A. D.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (02) : 47 - 54
  • [23] Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture
    Vijayvargiya, Mayank
    Pathak, Abhishek
    Gaur, Sanjiv
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (08) : RC1 - RC5
  • [24] Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus
    Matassi, Fabrizio
    Angeloni, Renzo
    Carulli, Christian
    Civinini, Roberto
    Di Bella, Leonardo
    Redl, Birgit
    Innocenti, Massimo
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (11): : 1939 - 1942
  • [25] Fixed-angle locking proximal humerus plate: an evaluation of functional results and implant-related outcomes
    Pak, Ponnaren
    Eng, Kevin
    Page, Richard S.
    ANZ JOURNAL OF SURGERY, 2013, 83 (11) : 878 - 882
  • [26] Arthroscopic removal of proximal humerus locking plates
    Dines, Joshua S.
    Hettrich, Carolyn M.
    Kelly, Bryan T.
    Savoie, Felix H., III
    Lorich, Dean G.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (03) : 409 - 411
  • [27] Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate?
    Woo-Bin Jung
    Eun-Sun Moon
    Sung-Kyu Kim
    David Kovacevic
    Myung-Sun Kim
    BMC Musculoskeletal Disorders, 14
  • [28] A prospective study of a new locking plate for proximal humeral fracture
    Bigorre, N.
    Talha, A.
    Cronier, P.
    Hubert, L.
    Toulemonde, J. L.
    Massin, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (02): : 192 - 196
  • [29] Biomechanical comparison of tuberosity-based proximal humeral locking plate compared to standard proximal humeral locking plate in varus cantilever bending
    Saunders, Patrick E.
    Castaneda, Paulo
    Walker, Robert
    McKee, Michael D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (11): : 3650 - 3654
  • [30] Open reduction and locking plate fixation of displaced proximal humerus fractures
    Kumar, Chandan
    Gupta, Anil Kumar
    Nath, Rohit
    Ahmad, Javed
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (02) : 156 - 160