共 31 条
Pitfalls and complications with locking plate for proximal humerus fracture
被引:205
作者:
Clavert, Philippe
[1
]
Adam, Philippe
[1
]
Bevort, Adrien
[1
]
Bonnomet, Francois
[1
]
Kempf, Jean-Francois
[1
]
机构:
[1] CHU Strasbourg, CCOM, Shoulder & Elbow Serv, F-67400 Illkirch Graffenstaden, France
关键词:
Shoulder;
proximal humerus fracture;
complication;
locking plate;
OPEN REDUCTION;
INTERNAL-FIXATION;
LOCKED PLATE;
TRAUMA CARE;
HEMIARTHROPLASTY;
MULTICENTER;
SHOULDER;
D O I:
10.1016/j.jse.2009.09.005
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
Purpose: The aim of this study was to identify specific complications of locking plate fixation of proximal humerus fractures. Patients and Methods: Seventy-threee adult patients with a displaced 3- (24%) or 4-part (76%) fracture of the proximal humerus were treated over a period of 2 years under the supervision of a trauma surgeon. Fourty-four patients came back for a clinical and radiographic examinations at least 18 months after the trauma; the others were evaluated at,6 weeks and 3 and 6 months. Results: Out of the 73 patients (64.4% females, mean age of 65), 11 patients needed a second surgery and 18 were lost for follow-up after 6 months. Mean final constant score was 62.3 points. The incidence of secondary displacement was 8.2%. Nonunion rate was 5.5%, affecting the constant score (P=.018). 16.4% of the patients developed a partial necrosis of the humeral head at the latest follow-up, which influenced on the constant score (P=.029). Quality of the reduction of the greater tuberosity influenced final results (P=.037). Screw cutout rate was 13.7%, with an influence to the constant score (P=.001). A too high plate positioning influenced the constant score (P=.002). Conclusion: Locked screw-plates provide more secure fixation of fractures, especially in weak bone. Complications rate remains high. Two complications are to be distinguished: 1) technical complications in plate positioning, length of the screws or secondary screw cutout strongly influence the final clinical result; and 2) specific complications related to this technology such as pseudarthrosis or plate fracture.
引用
收藏
页码:489 / 494
页数:6
相关论文