Cerebral oximetry does not correlate with electroencephalography and somatosensory evoked potentials in determining the need for shunting during carotid endarterectomy

被引:40
作者
Friedell, Mark L. [1 ]
Clark, Jason M. [1 ]
Graham, David A. [1 ]
Isley, Michael R. [2 ]
Zhang, Xiao-Feng [2 ]
机构
[1] Orlando Reg Healthcare, Dept Surg Educ, Orlando, FL USA
[2] Orlando Reg Healthcare, Dept Intraoperat Neuromonitoring, Orlando, FL USA
关键词
D O I
10.1016/j.jvs.2008.04.065
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Several reports in the literature have described the value of regional cerebral oximetry (rSO(2)) as a neuromonitoring device during carotid endarterectomy (CEA). The use of rSO(2) is enticing because it is simpler and less expensive than other neuromonitoring modalities. This study was performed to compare the efficacy of rSO, with electroencephalography (EEG) and median nerve somatosensory evoked potentials (SSEP) in determining when to place a shunt during CEA. Methods. From October 2000 to June 2006, 323 CEAs were performed under general anesthesia by six surgeons. Shunting was done selectively oil the basis of EEG and SSEP monitoring under the auspices of all intraoperative neurophysiologist. All patients were retrospectively reviewed to see if significant discrepancies existed between EEG/ SSEP and rSO(2). Results: Twenty-four patients (7.4%) showed significant discrepancies. Sixteen patients showed no significant EEG/SSEP changes, but profound changes occurred in rSO(2), and no shunt was placed. In seven patients there was no change in rSO, but a profound change occurred in EEG/SSEP, and shunts were placed. In one patient early in the series, the EEG and SSEP were unchanged but the rSO(2) dropped precipitously, and a shunt was placed. In the 299 patients who showed no discrepancies, 285 were not Shunted and 14 required a shunt. Two strokes occurred in the entire series (0.6%), none intraoperatively. Shunts were placed in 23 patients (7%). The sensitivity of rSO(2) compared with EEG/SSEP was 68%, and the specificity was 94%. This gave a positive-predictive value of 47% and a negative-predictive value of 98%. Conclusions. Relying oil rSO(2) alone for selective shunting is potentially dangerous and might have led to intraoperative ischemic strokes in seven patients and the unnecessary use of shunts in at least 16 patients in this series. The use of rSO(2) adds nothing to the information already provided by EEG and SSEP in determining when to place a shunt during CEA.
引用
收藏
页码:601 / 606
页数:6
相关论文
共 40 条
[1]  
Ahn S S, 1995, Semin Vasc Surg, V8, P29
[2]   Continuous intraoperative monitoring of middle cerebral artery blood flow velocities and electroencephalography during carotid endarterectomy - A comparison of the two methods to detect cerebral ischemia [J].
Arnold, M ;
Sturzenegger, M ;
Schaffler, L ;
Seiler, RW .
STROKE, 1997, 28 (07) :1345-1350
[3]  
BAKER WH, 1984, J VASC SURG, V1, P50
[4]   Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy [J].
Beese, U ;
Langer, H ;
Lang, W ;
Dinkel, M .
STROKE, 1998, 29 (10) :2032-2037
[5]   The use of near-infrared cerebral oximetry in awake carotid endarterectomy [J].
Carlin, RE ;
McGraw, DJ ;
Calimlim, JR ;
Mascia, MF .
JOURNAL OF CLINICAL ANESTHESIA, 1998, 10 (02) :109-113
[6]   Anesthesia for carotid endarterectomy: A survey [J].
Cheng, MA ;
Theard, MA ;
Tempelhoff, R .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1997, 9 (03) :211-216
[7]   Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy [J].
Cho, H ;
Nemoto, EM ;
Yonas, H ;
Balzer, J ;
Sclabassi, RJ .
JOURNAL OF NEUROSURGERY, 1998, 89 (04) :533-538
[8]  
Cuadra Salvador A, 2003, Vasc Endovascular Surg, V37, P407, DOI 10.1177/153857440303700604
[9]  
de Letter JAM, 1998, NEUROL RES, V20, pS23
[10]   CEREBRAL OXIMETRY - A USEFUL MONITOR DURING CAROTID-ARTERY SURGERY [J].
DUNCAN, LA ;
RUCKLEY, CV ;
WILDSMITH, JAW .
ANAESTHESIA, 1995, 50 (12) :1041-1045