Cadaveric Simulation of Endoscopic Endonasal Procedures: Analysis of Droplet Splatter Patterns During the COVID-19 Pandemic

被引:43
作者
Sharma, Dhruv [1 ]
Rubel, Kolin E. [1 ]
Ye, Michael J. [1 ]
Shipchandler, Taha Z. [1 ]
Wu, Arthur W. [2 ]
Higgins, Thomas S. [3 ,4 ]
Burgin, Sarah J. [1 ]
Ting, Jonathan Y. [1 ]
Illing, Elisa A. [1 ]
机构
[1] Indiana Univ, Dept Otolaryngol Head & Neck Surg, Indianapolis, IN 46202 USA
[2] Cedars Sinai, Dept Otolaryngol Head & Neck Surg, Los Angeles, CA USA
[3] Univ Louisville, Dept Otolaryngol Head & Neck Surg, Louisville, KY 40292 USA
[4] Kentuckiana Ear Nose & Throat, Rhinol Sinus & Skull Base, Louisville, KY USA
关键词
COVID-19; nasal endoscopy; sinus surgery; skull base surgery; droplet; splatter;
D O I
10.1177/0194599820929274
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective The primary mode of viral transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is thought to occur through the spread of respiratory droplets. The objective of this study was to investigate droplet and splatter patterns resulting from common endoscopic endonasal procedures. Study Design Cadaver simulation series. Setting Dedicated surgical laboratory. Subjects and Methods After instilling cadaver head specimens (n = 2) with fluorescein solution, endoscopic endonasal procedures were systematically performed to evaluate the quantity, size, and distance of droplets and splatter following each experimental condition. Results There were no observable fluorescein droplets or splatter noted in the measured surgical field in any direction after nasal endoscopy, septoplasty with microdebrider-assisted turbinoplasty, cold-steel functional endoscopic sinus surgery (FESS), and all experimental conditions using an ultrasonic aspirator. Limited droplet spread was noted with microdebrider FESS (2 droplets, <1 mm in size, within 10 cm), drilling of the sphenoid rostrum with a diamond burr (8, <1 mm, 12 cm), and drilling of the frontal beak with a cutting burr (5, <1 mm, 9 cm); however, the use of concurrent suction while drilling resulted in no droplets or splatter. The control condition of external activation of the drill resulted in gross contamination (11, 2 cm, 13 cm). Conclusion Our results indicate that there is very little droplet generation from routine rhinologic procedures. The droplet generation from drilling was mitigated with the use of concurrent suction. Extreme caution should be used to avoid activating powered instrumentation outside of the nasal cavity, which was found to cause droplet contamination.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 17 条
[1]  
American Academy of Otolaryngology-Head and Neck Surgery, 2020, HEAD NECK SURG OT CO
[2]  
American Academy of Otolaryngology-Head and Neck Surgery, 2020, HEAD NECK SURG AC SU
[3]  
[Anonymous], 2020, RADIOLOGY, V295, P715
[4]  
Bahl P, 2020, J INFECT DIS
[5]   SARS and MERS: recent insights into emerging coronaviruses [J].
de Wit, Emmie ;
van Doremalen, Neeltje ;
Falzarano, Darryl ;
Munster, Vincent J. .
NATURE REVIEWS MICROBIOLOGY, 2016, 14 (08) :523-534
[6]  
Fehr AR, 2015, METHODS MOL BIOL, V1282, P1, DOI 10.1007/978-1-4939-2438-7_1
[7]   Nosocomial Transmission of Emerging Viruses via Aerosol-Generating Medical Procedures [J].
Judson, Seth D. ;
Munster, Vincent J. .
VIRUSES-BASEL, 2019, 11 (10)
[8]   Aerosol Generating Procedures and Risk of Transmission of Acute Respiratory Infections to Healthcare Workers: A Systematic Review [J].
Khai Tran ;
Cimon, Karen ;
Severn, Melissa ;
Pessoa-Silva, Carmem L. ;
Conly, John .
PLOS ONE, 2012, 7 (04)
[9]   Integrated infection control strategy to minimize nosocomial infection of coronavirus disease 2019 among ENT healthcare workers [J].
Lu, D. ;
Wang, H. ;
Yu, R. ;
Yang, H. ;
Zhao, Y. .
JOURNAL OF HOSPITAL INFECTION, 2020, 104 (04) :454-455
[10]  
Patel ZM, 2020, NEUROSURGERY