Development and application of a liquid chromatography coupled to mass spectrometry method for the simultaneous determination of 23 antineoplastic drugs at trace levels

被引:9
|
作者
Fleury-Souverain, S. [1 ,2 ]
Maurin, J. [1 ,2 ]
Guillarme, D. [1 ]
Rudaz, S. [1 ]
Bonnabry, P. [1 ,2 ]
机构
[1] Univ Geneva, Inst Pharmaceut Sci Western Switzerland ISPSO, Sch Pharmaceut Sci, CMU, Rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
[2] Geneva Univ Hosp HUG, Pharm, Geneva, Switzerland
关键词
Antineoplastic drug; Reversed phase liquid chromatography; Mass spectrometry; Surface analyses; Trace analysis; URINE MUTAGENICITY; DNA-DAMAGE; EXPOSURE; NURSES; LYMPHOCYTES; CISPLATIN; PERSONNEL; PHARMACY; WORKING;
D O I
10.1016/j.jpba.2022.115034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The goal of this study was to develop a method for the simultaneous quantification of 23 commonly used antineoplastic drugs in a hospital pharmacy, using ultra-high pressure liquid chromatography separation coupled to tandem mass spectrometry detection (UHPLC-MS/MS). The following drugs were investigated: 5-fluorouracil, cytarabine, ganciclovir, gemcitabine, dacarbazine, methotrexate, pemetrexed, busulfan, topotecan, rentitrexed, ifosfamide, cyclophosphamide, etoposide, irinotecan, doxorubicin/epirubicin, vincristine, docetaxel, paclitaxel, daunorubicin, idarubicin, vinblastine, oxaliplatin and carboplatin. The chromatographic separation was performed on a phenyl-hexyl column (2.1 x100 mm, 1.7 mu m) with a gradient elution of methanol and water containing 10 mM ammonium formate adjusted to pH 4.9. All compounds were analyzed in less than 13 min and detected with a triple quadrupole mass spectrometer operating in MRM mode. Limits of detection (LODs) and limits of quantification (LOQs) were comprised between 0.01 and 5 ng.mL(-1), and between 0.5 and 5 ng.mL(-1), respectively. Accuracies ranged between 117% and 83% at the LOQ, intermediate and upper LOQ concentrations, with relative standard deviations (RSD) inferior to 8%, for all the antineoplastic drugs. Finally, the UHPLCMS/MS method was successfully applied to the analysis of surface samples to evaluate the chemical contamination by these highly toxic compounds in a chemotherapy preparation unit in a hospital pharmacy with the purpose of monitoring the exposure of health care professionals.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Simultaneous Determination of Residual Contamination of Eight Antineoplastic on Surfaces by HILIC Chromatography Coupled to High-Resolution Spectrometry
    Kaouther, Zribi
    Berriri, Sarra
    Libong, Danielle
    Solgadi, Audrey
    Safta, Fathi
    Le, Laetitia Minh Mai
    Caudron, Eric
    ANALYTICAL SCIENCE ADVANCES, 2025, 6 (01):
  • [22] Determination of Abamectin in Soybean Roots by Liquid Chromatography Coupled to Tandem Mass Spectrometry
    de Oliveira, Eliezer
    da Silva, Bianca Ferreira
    Bottoli, Carla Beatriz Grespan
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 11 (44): : 76 - 84
  • [23] Determination of Neonicotinoid Pesticides in Propolis with Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Tomsic, Rok
    Heath, David
    Heath, Ester
    Markelj, Jernej
    Borovsak, Andreja Kandolf
    Prosen, Helena
    MOLECULES, 2020, 25 (24):
  • [24] Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of nine corticosteroid residues in bovine liver samples
    Dusi, Guglielmo
    Gasparini, Mara
    Curatolo, Michele
    Assini, Walter
    Bozzoni, Eros
    Tognoli, Nadia
    Ferretti, Enrica
    ANALYTICA CHIMICA ACTA, 2011, 700 (1-2) : 49 - 57
  • [25] Pentacyclic triterpene in Olea europaea L: A simultaneous determination by high-performance liquid chromatography coupled to mass spectrometry
    Gimenez, Estela
    Emilia Juan, M.
    Calvo-Melia, Sara
    Barbosa, Jose
    Sanz-Nebot, Victoria
    Planas, Joana M.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1410 : 68 - 75
  • [26] Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of phthalates and bisphenol a in serum, urine and follicular fluid
    Dima, Anna Pia
    De Santis, Lucia
    Verlengia, Cristina
    Lombardo, Francesco
    Lenzi, Andrea
    Mazzarino, Monica
    Botre, Francesco
    Paoli, Donatella
    CLINICAL MASS SPECTROMETRY, 2020, 18 : 54 - 65
  • [27] Determination of trace levels of platinum in biological materials by inductively coupled plasma mass spectrometry
    Kitagawa, S
    Tanaka, H
    Okamoto, K
    Etoh, T
    Matsubara, M
    BUNSEKI KAGAKU, 1996, 45 (06) : 511 - 516
  • [28] Determination of cyclophosphamide and ifosphamide in urine at trace levels by gas chromatography/tandem mass spectrometry
    Sannolo, N
    Miraglia, N
    Biglietto, M
    Acampora, A
    Malorni, A
    JOURNAL OF MASS SPECTROMETRY, 1999, 34 (08): : 845 - 849
  • [29] A method to determine BPA, BPB, and BPF levels in fruit juices by liquid chromatography coupled to tandem mass spectrometry
    Gallo, Pasquale
    Di Marco Pisciottano, Ilaria
    Fattore, Margherita
    Rimoli, Maria Grazia
    Seccia, Serenella
    Albrizio, Stefania
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2019, 36 (12): : 1871 - 1881
  • [30] Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry
    Lee, Chaelin
    Kim, Chong Hyeak
    Kim, Sunghwan
    Cho, Sung-Hee
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1058 : 8 - 13