A new concept for navigated laser surgery

被引:16
作者
Stopp, Sebastian [1 ]
Deppe, Herbert [2 ]
Lueth, Tim [1 ]
机构
[1] Tech Univ Munich, MIMED Lehrstuhl Mikrotech & Med Tech, D-85748 Garching, Germany
[2] Tech Univ Munich Fachgebiet, Klin & Poliklin Mund Kiefer & Gesichtschirurg MKG, D-81675 Munich, Germany
关键词
navigation; laser; calibration; navigated control;
D O I
10.1007/s10103-007-0476-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this article, a new concept for navigated laser surgery is presented. Mechanically rotating instruments such as drills or mills for bone treatment have the disadvantage of damaging the surrounding bone by the generated frictional heat. Cooling of the instrument cannot avoid this damage completely. Laser systems are an alternative solution for bone removal. Areas of application for bone treatment laser systems are the dental implantology and the osteotomy. The goal of the approach presented here was to combine the advantages of laser treatment with the precision and safety of navigated control. During the use of medical laser systems, the tissue is not only removed exactly in the focus of the laser. It is removed inside of a remove range around the focus. The amount of removed bone cannot be determined only by performance adjustment and the position of the laser because the size of the remove range is unknown. The new approach is to use a position- and orientation-dependent power-controlled laser. Therefore, a calibration of the laser parameters has to be accomplished. The position and orientation of the laser handpiece is measured by an optical measurement system. The laser parameters and the tissue properties are determined by a calibration procedure. On the basis of a preoperative planning, the laser remove range is adjusted by modulation of the laser power. Near to border areas or sensitive structure, the laser power is decreased. Therewith, a precise and safe bone removal according to a preoperative planning without damaging the bone by frictional heat is possible. The inaccuracies as result of simplifications by the calibration procedure have to be verified.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 30 条
  • [1] Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws
    Allan, W
    Williams, ED
    Kerawala, CJ
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2005, 43 (04) : 314 - 319
  • [2] Thermal changes observed at implant sites during internal and external irrigation
    Benington, IC
    Biagioni, PA
    Briggs, J
    Sheridan, S
    Lamey, PJ
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 293 - 297
  • [3] Bornstein Eric, 2004, Dent Today, V23, P86
  • [4] Bornstein Eric S, 2003, Dent Today, V22, P129
  • [5] Heat production by 3 implant drill systems after repeated drilling and sterilization
    Chacon, GE
    Bower, DL
    Larsen, PE
    McGlumphy, EA
    Beck, FM
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (02) : 265 - 269
  • [6] Drilling in bone: Modeling heat generation and temperature distribution
    Davidson, SRH
    James, DF
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 305 - 314
  • [7] Electron probe micro-analysis of a contact probe after Er:YAG laser tooth
    Eguro, T
    Maeda, T
    Ogawa, M
    Yonemoto, K
    Tanaka, H
    Katsuumi, I
    [J]. DENTAL MATERIALS JOURNAL, 2003, 22 (01) : 80 - 86
  • [8] el-Montaser M, 1999, Implant Dent, V8, P79, DOI 10.1097/00008505-199901000-00010
  • [9] The effect of working tip angulation on root substance removal using Er:YAG laser radiation:: an in vitro study
    Folwaczny, M
    Thiele, L
    Mehl, A
    Hickel, R
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2001, 28 (03) : 220 - 226
  • [10] FRANK F, 2003, APPL LASER MED, P151