Automated microaneurysm detection method based on double-ring filter in retinal fundus images

被引:29
作者
Mizutani, Atsushi [1 ]
Muramatsu, Chisako [1 ]
Hatanaka, Yuji [2 ]
Suemori, Shinsuke [1 ]
Hara, Takeshi [1 ]
Fujita, Hiroshi [1 ]
机构
[1] Gifu Univ, Grad Sch Med, Dept Intelligent Image Informat, 1-1 Yanagido, Gifu, Gifu 5011194, Japan
[2] Univ Shiga Prefecture, Sch Engn, Hikone, Shiga 5220057, Japan
来源
MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS | 2009年 / 7260卷
关键词
Fundus images; Diabetic retinopathy; Microaneurysm; Computer-aided diagnosis;
D O I
10.1117/12.813468
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The presence of microaneurysms in the eye is one of the early signs of diabetic retinopathy, which is one of the leading causes of vision loss. We have been investigating a computerized method for the detection of microaneurysms on retinal fundus images, which were obtained from the Retinopathy Online Challenge (ROC) database. The ROC provides 50 training cases, in which "gold standard" locations of microaneurysms are provided, and 50 test cases without the gold standard locations. In this study, the computerized scheme was developed by using the training cases. Although the results for the test cases are also included, this paper mainly discusses the results for the training cases because the "gold standard" for the test cases is not known. After image preprocessing, candidate regions for microaneurysms were detected using a double-ring filter. Any potential false positives located in the regions corresponding to blood vessels were removed by automatic extraction of blood vessels from the images. Twelve image features were determined, and the candidate lesions were classified into microaneurysms or false positives using the rule-based method and an artificial neural network. The true positive fraction of the proposed method was 0.45 at 27 false positives per image. Forty-two percent of microaneurysms in the 50 training cases were considered invisible by the consensus of two co-investigators. When the method was evaluated for visible microaneurysms, the sensitivity for detecting microaneurysms was 65% at 27 false positives per image. Our computerized detection scheme could be improved for helping ophthalmologists in the early diagnosis of diabetic retinopathy.
引用
收藏
页数:8
相关论文
共 16 条
[1]  
Abramoff Michael D., ROC WEBS
[2]   Automated microaneurysm detection using local contrast normalization and local vessel detection [J].
Fleming, Alan D. ;
Philip, Sam ;
Goatman, Keith A. ;
Olson, John A. ;
Sharp, Peter F. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (09) :1223-1232
[3]  
Grisan E, 2007, P ANN INT IEEE EMBS, P6736
[4]  
Hatanaka Y., 2005, 8 INT C MED IM COMP
[5]  
Hatanaka Y., 2005, P 27 IEEE EMBS SHANG
[6]   Improvement of automatic hemorrhages detection methods using brightness correction on fundus images [J].
Hatanaka, Yuji ;
Nakagawa, Toshiaki ;
Hayashi, Yoshinori ;
Kakogawa, Masakatsu ;
Sawada, Akira ;
Kawase, Kazuhide ;
Hara, Takeshi ;
Fujita, Hiroshi .
MEDICAL IMAGING 2008: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2008, 6915
[7]   Detection of retinal nerve fiber layer defects in retinal fundus images using gabor filtering [J].
Hayashi, Yoshinori ;
Nakagawa, Toshiaki ;
Hatanaka, Yuji ;
Aoyama, Akira ;
Kakogawa, Masakatsu ;
Hara, Takeshi ;
Fujita, Hiroshi ;
Yamamoto, Tetsuya .
MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514
[8]  
Kasai S., 1999, J COMPUTER AIDED DIA, V3
[9]  
Kinano S, DIABETES NEWS
[10]  
Ministry of Health Labour and Welfare in Japan, 2008, OV JAP HLTH NUTR SUR, P29