摘要
Purpose: To evaluate a new method of treatment planning that incorporates collimator rotation into MLC based fluence segmentation. Method and Materials: A set of treatment plans were generated using a new technique for fluence segmentation where the collimator is rotated in between each MLC sub‐field. It was previously shown that this technique has improved spatial resolution, increased flexibility in generating aperture shapes and decreased systematic error due to interleaf effects. Unfortunately these studies were limited to single fields. In this study we evaluate the ability of the rotating collimator technique to generate conformal dose distributions by comparing to conventional IMRT plans. Plans for a simple geometric phantom as well as a prostate and nasopharynx carcinoma recurrence were generated. One set of plans was generated with a conventional step‐and‐shoot delivery method (no MLC rotation) while a second set was generated with the collimator rotation segmentation method. Results: 3D dose comparisons as well as DVH analyses show that target coverage is equivalent or better with collimator rotation. Healthy tissue sparing is improved with collimator rotation, although more so for the smaller, more complex, nasopharynx target. It is also shown that increasing radiation efficiency (decreasing monitor units) will increase healthy tissue sparing. A decrease in the number of monitor units is seen with collimator rotation for both clinical cases. Conclusion: By incorporating MLC rotation into IMRT planning it is possible to improve target conformity and healthy tissue sparing. These benefits are more significant for smaller targets of higher complexity. The number of monitor units will also decrease, providing less transmission and total body scatter dose. Conflict of Interest: This work was supported in part by Varian Medical Systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1967 / 1968
页数:2
相关论文
共 50 条
  • [31] Controlling dose falloff in IMRT treatment planning: the "anchor zone" method
    Zakarian, C
    Deasy, J
    Alaly, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1875 - 1875
  • [32] Treatment Planning Techniques to Reduce Radiation Dose for Head and Neck IMRT
    Dumane, V. A.
    Veksman, I.
    Svoboda, A.
    Kao, J.
    Lo, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S412 - S412
  • [33] Equivalent uniform dose (EUD) based optimization for IMRT treatment planning
    Mihailidis, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2295 - 2295
  • [34] Comparison of Treatment Planning Systems' shallow depth dose prediction for IMRT
    Bogaert, E.
    Pittomvils, G.
    De Wagter, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S972 - S973
  • [35] Effect of various methods for rectum delineation on relative and absolute dose-volume histograms for prostate IMRT treatment planning
    Kusumoto, Chiaki
    Ohira, Shingo
    Miyazaki, Masayoshi
    Ueda, Yoshihiro
    Isono, Masaru
    Teshima, Teruki
    MEDICAL DOSIMETRY, 2016, 41 (02) : 136 - 141
  • [36] Commercial IMRT treatment-planning dose-calculation algorithm
    Low, DA
    Mutic, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04): : 933 - 937
  • [37] A method for improving simplified pencil beam dose in IMRT treatment planning
    Riegel, A
    Chen, Y
    Galvin, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1856 - 1856
  • [38] Optimal IMRT treatment planning with prescribed trapezoidal fuzzy target dose
    Bozorg O.
    Khalafi A.D.
    Jahromi A.F.
    Soft Computing, 2024, 28 (13-14) : 7861 - 7873
  • [39] Estimated limits of IMRT dose escalation using varied planning target volume margins
    Goulet, Christopher C.
    Herman, Michael G.
    Hillman, David W.
    Davis, Brian J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3777 - 3788
  • [40] Absent from the dose volume histogram: Dose rate and fraction size to normal lung with IMRT planning for NSCLC
    Murphy, C.
    Kuritzky, N.
    Morgan, P.
    Li, S.
    Miyamoto, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S454 - S454