IMRT with MLC rotation - Dose volume benefits of high precision treatment planning

被引:0
|
作者
Otto, K [1 ]
机构
[1] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
关键词
D O I
10.1118/1.1997750
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a new method of treatment planning that incorporates collimator rotation into MLC based fluence segmentation. Method and Materials: A set of treatment plans were generated using a new technique for fluence segmentation where the collimator is rotated in between each MLC sub‐field. It was previously shown that this technique has improved spatial resolution, increased flexibility in generating aperture shapes and decreased systematic error due to interleaf effects. Unfortunately these studies were limited to single fields. In this study we evaluate the ability of the rotating collimator technique to generate conformal dose distributions by comparing to conventional IMRT plans. Plans for a simple geometric phantom as well as a prostate and nasopharynx carcinoma recurrence were generated. One set of plans was generated with a conventional step‐and‐shoot delivery method (no MLC rotation) while a second set was generated with the collimator rotation segmentation method. Results: 3D dose comparisons as well as DVH analyses show that target coverage is equivalent or better with collimator rotation. Healthy tissue sparing is improved with collimator rotation, although more so for the smaller, more complex, nasopharynx target. It is also shown that increasing radiation efficiency (decreasing monitor units) will increase healthy tissue sparing. A decrease in the number of monitor units is seen with collimator rotation for both clinical cases. Conclusion: By incorporating MLC rotation into IMRT planning it is possible to improve target conformity and healthy tissue sparing. These benefits are more significant for smaller targets of higher complexity. The number of monitor units will also decrease, providing less transmission and total body scatter dose. Conflict of Interest: This work was supported in part by Varian Medical Systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1967 / 1968
页数:2
相关论文
共 50 条
  • [1] Dose volume benefits and delivery accuracy of a novel rotating collimator precision IMRT technique
    Otto, K
    Schmuland, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S106 - S106
  • [2] Independent validation of CORVUS MLC IMRT dose distributions using ADAC treatment planning system
    Ayyangar, KM
    Saw, CB
    Yoe-Sein, M
    Zhen, W
    Raman, N
    Enke, CA
    MEDICAL PHYSICS, 2002, 29 (06) : 1271 - 1272
  • [3] The use of optimized treatment planning high dose & high precision radiotherapy - Biological basis and volume effect
    Ling, CC
    VOLUME & KINETICS IN TUMOR CONTROL & NORMAL TISSUE COMPLICATIONS, 1998, : 408 - 408
  • [4] Comparison of rectal dose-volume constraints for IMRT prostate treatment planning
    Odrazka, K
    Zouhar, M
    Petera, J
    Vaculikova, M
    Dolezel, M
    Vosmik, M
    Tucek, P
    PHYSICA MEDICA, 2005, 21 (04) : 129 - 135
  • [5] The effect of collimator rotation on IMRT treatment planning
    Loan, S
    Heintz, PH
    Sorensen, SA
    Jimenez, AA
    Roedersheimer, KD
    Chen, DZ
    Wong, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S524 - S525
  • [6] Optimizing the MLC Model Parameters for IMRT in the RayStation Treatment Planning System
    Chen, S.
    Yi, B.
    Xu, H.
    Yang, X.
    Prado, K.
    D' Souza, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 362 - +
  • [7] Commissioning of a commercial IMRT treatment planning system for standard elekta MLC
    Kim, H
    Chen, Y
    Xiao, Y
    Anne, P
    Galvin, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1348 - 1348
  • [8] Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system
    Chen, Shifeng
    Yi, Byong Yong
    Yang, Xiaocheng
    Xu, Huijun
    Prado, Karl L.
    D'Souza, Warren D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (05): : 322 - 332
  • [9] Combining CBCT Dose Into IMRT Treatment Planning
    Grelewicz, Z.
    Wiersma, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 163 - 163
  • [10] Commissioning and clinical implementation of Elekta MLC IMRT with Corvus inverse treatment planning
    Wallace, S
    Bobba, V
    Koll, W
    Zhang, Y
    Holt, R
    MEDICAL PHYSICS, 2005, 32 (06) : 1896 - 1896