A membrane-based, high-efficiency, microfluidic debubbler

被引:64
作者
Liu, Changchun [1 ]
Thompson, Jason A. [1 ]
Bau, Haim H. [1 ]
机构
[1] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
关键词
CELL-CULTURE; PROTEIN; SYSTEM; ARRAY;
D O I
10.1039/c1lc20089e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In many lab-on-chip applications, it is necessary to remove bubbles from the flow stream. Existing bubble removal strategies have various drawbacks such as low degassing efficiency, long degassing time, large dead volumes, sensitivity to surfactants, and the need for an external vacuum or pressure source. We report on a novel, simple, robust, passive, nozzle-type, membrane-based debubbler that can be readily incorporated into microfluidic devices for rapid degassing. The debubbler is particularly suitable to operate with microfluidic systems made with plastic. The debubbler consists of a hydrophobic, porous membrane that resembles a normally closed valve, which is forced open by the working fluid's pressure. To illustrate the operation of the debubbler, we describe its use in the context of a chip containing a bead array for immunoassays. Our debubbler was able to completely filter gas bubbles out of a segmented flow at rates up to 60 mu l s(-1) mm(-2) of membrane area.
引用
收藏
页码:1688 / 1693
页数:6
相关论文
共 24 条
[1]  
Barbee KD, 2010, LAB CHIP, V10, P3084, DOI [10.1039/c0lc00044b, 10.1039/c01c00044b]
[2]   Electric field directed assembly of high-density microbead arrays [J].
Barbee, Kristopher D. ;
Hsiao, Alexander P. ;
Heller, Michael J. ;
Huang, Xiaohua .
LAB ON A CHIP, 2009, 9 (22) :3268-3274
[3]   A debubbler for microfluidics utilizing air-liquid interfaces [J].
Cheng, Daming ;
Jiang, Hongrui .
APPLIED PHYSICS LETTERS, 2009, 95 (21)
[4]   Application of microchip assay system for the measurement of C-reactive protein in human saliva [J].
Christodoulides, N ;
Mohanty, S ;
Miller, CS ;
Langub, MC ;
Floriano, PN ;
Dharshan, P ;
Ali, MF ;
Bernard, B ;
Romanovicz, D ;
Anslyn, E ;
Fox, PC ;
McDevitt, JT .
LAB ON A CHIP, 2005, 5 (03) :261-269
[5]   Use of Saliva-Based Nano-Biochip Tests for Acute Myocardial Infarction at the Point of Care: A Feasibility Study [J].
Floriano, Pierre N. ;
Christodoulides, Nicolaos ;
Miller, Craig S. ;
Ebersole, Jeffrey L. ;
Spertus, John ;
Rose, Beate G. ;
Kinane, Denis F. ;
Novak, M. John ;
Steinhubl, Steven ;
Acosta, Shelley ;
Mohanty, Sanghamitra ;
Dharshan, Priya ;
Yeh, Chih-ko ;
Redding, Spencer ;
Furmaga, Wieslaw ;
McDevitt, John T. .
CLINICAL CHEMISTRY, 2009, 55 (08) :1530-1538
[6]   Diagnostic real-time PCR assays for the detection of emetic Bacillus cereus strains in foods and recent food-borne outbreaks [J].
Fricker, Martina ;
Messelhaeusser, Ute ;
Busch, Ulrich ;
Scherer, Siegfried ;
Ehling-Schulz, Monika .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2007, 73 (06) :1892-1898
[7]   Microfluidic arrays for logarithmically perfused embryonic stem cell culture [J].
Kim, L ;
Vahey, MD ;
Lee, HY ;
Voldman, J .
LAB ON A CHIP, 2006, 6 (03) :394-406
[8]   Cell culture in 3-dimensional microfluidic structure of PDMS (polydimethylsiloxane) [J].
Leclerc, E ;
Sakai, Y ;
Fujii, T .
BIOMEDICAL MICRODEVICES, 2003, 5 (02) :109-114
[9]   Disposable polydimethylsiloxane/silicon hybrid chips for protein detection [J].
Li, SF ;
Floriano, PN ;
Christodoulides, N ;
Fozdar, DY ;
Shao, DB ;
Ali, MF ;
Dharshan, P ;
Mohanty, S ;
Neikirk, D ;
McDevitt, JT ;
Chen, SC .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (04) :574-580
[10]   A hard-soft microfluidic-based biosensor flow cell for SPR imaging application [J].
Liu, Changchun ;
Cui, Dafu ;
Li, Hui .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :255-261