Design of a predictive targeting error simulator for MRI-guided prostate biopsy

被引:0
作者
Avni, Shachar [1 ]
Vikal, Siddharth [1 ]
Fichtinger, Gabor [1 ]
机构
[1] Queens Univ, Sch Comp, Kingston, ON, Canada
来源
MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING | 2010年 / 7625卷
关键词
Segmentation; validation; error; modeling; prostate; cancer; MRI; biopsy;
D O I
10.1117/12.844476
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Multi-parametric MRI is a new imaging modality superior in quality to Ultrasound (US) which is currently used in standard prostate biopsy procedures. Surface-based registration of the pre-operative and intra-operative prostate volumes is a simple alternative to side-step the challenges involved with deformable registration. However, segmentation errors inevitably introduced during prostate contouring spoil the registration and biopsy targeting accuracies. For the crucial purpose of validating this procedure, we introduce a fully interactive and customizable simulator which determines the resulting targeting errors of simulated registrations between prostate volumes given user-provided parameters for organ deformation, segmentation, and targeting. We present the workflow executed by the simulator in detail and discuss the parameters involved. We also present a segmentation error introduction algorithm, based on polar curves and natural cubic spline interpolation, which introduces statistically realistic contouring errors. One simulation, including all I/O and preparation for rendering, takes approximately 1 minute and 40 seconds to complete on a system with 3 GB of RAM and four Intel Core 2 Quad CPUs each with a speed of 2.40 GHz. Preliminary results of our simulation suggest the maximum tolerable segmentation error given the presence of a 5.0 mm wide small tumor is between 4-5 mm. We intend to validate these results via clinical trials as part of our ongoing work.
引用
收藏
页数:8
相关论文
共 15 条
[1]   MRI-guided biopsy of the prostate increases diagnostic performance in men with elevated or increasing PSA levels after previous negative TRUS biopsies [J].
Anastasiadis, Aristotelis G. ;
Lichy, Matthias P. ;
Nagele, Udo ;
Kuczyk, Markus A. ;
Merseburger, Axel S. ;
Hennenlotter, Joerg ;
Corvin, Stefan ;
Sievert, Karl-Dietrich ;
Claussen, Claus D. ;
Stenzl, Arnulf ;
Schlemmer, Heinz-Peter .
EUROPEAN UROLOGY, 2006, 50 (04) :738-749
[2]   ALGORITHM FOR COMPUTER CONTROL OF A DIGITAL PLOTTER [J].
BRESENHAM, JE .
IBM SYSTEMS JOURNAL, 1965, 4 (01) :25-30
[3]  
EISENBERG ML, 2009, UROLOGIC ON IN PRESS
[4]  
Fichtinger G, 2002, LECT NOTES COMPUT SC, V2488, P91
[5]  
GOKSEL O, COMPUTER AI IN PRESS
[6]   RANDOM SYSTEMATIC VERSUS DIRECTED ULTRASOUND GUIDED TRANS-RECTAL CORE BIOPSIES OF THE PROSTATE [J].
HODGE, KK ;
MCNEAL, JE ;
TERRIS, MK ;
STAMEY, TA .
JOURNAL OF UROLOGY, 1989, 142 (01) :71-75
[7]   Cancer statistics, 2008 [J].
Jemal, Ahmedin ;
Siegel, Rebecca ;
Ward, Elizabeth ;
Hao, Yongping ;
Xu, Jiaquan ;
Murray, Taylor ;
Thun, Michael J. .
CA-A CANCER JOURNAL FOR CLINICIANS, 2008, 58 (02) :71-96
[8]   A feasibility study of mutual information based setup error estimation for radiotherapy [J].
Kim, J ;
Fessler, JA ;
Lam, KL ;
Balter, JM ;
Ten Haken, RK .
MEDICAL PHYSICS, 2001, 28 (12) :2507-2517
[9]  
Leventon M., 2000, P IEEE C COMPUTER VI, P316, DOI DOI 10.1109/CVPR.2000.855835
[10]   The importance of organ geometry and boundary constraints for planning of medical interventions [J].
Misra, S. ;
Macura, K. J. ;
Ramesh, K. T. ;
Okamura, A. M. .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (02) :195-206