Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: A CT analysis

被引:143
作者
Rampersaud, YR
Pik, JHT
Salonen, D
Farooq, S
机构
[1] Univ Toronto, Div Orthopaed, Toronto, ON, Canada
[2] Canberra Hosp, Canberra, ACT, Australia
[3] Univ Toronto, Div Radiol, Toronto, ON, Canada
[4] Univ Toronto, Dept Publ Hlth Sci, Toronto, ON, Canada
[5] Univ Toronto, Div Neurosurg, Toronto, ON, Canada
关键词
computer-assisted; pedicle screws; fluoroscopy; accuracy; thoracic; lumbar;
D O I
10.1097/01.brs.0000157490.65706.38
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Observational cohort study with computerized tomography (CT) analysis of in vivo pedicle screw placement. Objective. To evaluate the clinical accuracy of computer-assisted fluoroscopy for the placement of thoracic and lumbosacral (LS) pedicle screws. Summary of Background Data. Computer-assisted fluoroscopy is an adjunct for the placement of pedicle screws. Methods. Postoperative CT of 360 titanium pedicle screws ( 281 LS [L1 - S1]; 79 thoracic [T2 - T12]) were independently assessed. All screws were placed using the FluoroNav(TM) system (Medtronic Surgical Navigation Technologies, Louisville, CO). The relative position of the screw to the pedicle was graded as follows: A = completely in; B = < 2 mm breach; C = 2 - 4 mm breach; and D = > 4 mm breach. If an osseous breach occurred, the direction of the breach was further classified. Results. Eight-five percent of screws were completely contained within the pedicle. Fifty-five-pedicle breaches ( 25 medial; 30 lateral) occurred. Pedicle breaches were graded B in 13.1% ( 47 breaches), C in 1.9% ( 7), and D in 0.3% ( 1) of screws. Pedicle breach was significantly higher in the thoracic compared to the LS spine, 31.6% (25/79) and 10.6% (30/281), respectively ( P < 0.0001). In the thoracic spine, 72% of pedicle breaches were lateral. In 49% of breaches, the screw diameter was larger than the pedicle diameter. None of the pedicle breaches were associated with neurologic or other clinical sequelae. Conclusions. The clinical pedicle breach rate in this study is comparable to those reported using conventional techniques with or without fluoroscopic assistance. FluoroNav(TM) appears to be a safe adjunct for the placement of thoracic and LS pedicle screws.
引用
收藏
页码:E183 / E190
页数:8
相关论文
共 49 条
[1]   Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine [J].
Amiot, LP ;
Lang, K ;
Putzier, M ;
Zippel, H ;
Labelle, H .
SPINE, 2000, 25 (05) :606-614
[2]   Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities [J].
Belmont, PJ ;
Klemme, WR ;
Robinson, M ;
Polly, DW .
SPINE, 2002, 27 (14) :1558-1566
[3]   In vivo accuracy of thoracic pedicle screws [J].
Belmont, PJ ;
Klemme, WR ;
Dhawan, A ;
Polly, DW .
SPINE, 2001, 26 (21) :2340-2346
[4]  
Berlemann U, 1997, J SPINAL DISORD, V10, P117
[5]   Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique [J].
Boachie-Adjei, O ;
Girardi, FP ;
Bansal, M ;
Rawlins, BA .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (06) :496-500
[6]   Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures [J].
Bolger, C ;
Wigfield, C .
JOURNAL OF NEUROSURGERY, 2000, 92 (02) :175-180
[7]   Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries - Technique and short-term complications [J].
Carbone, JJ ;
Tortolani, J ;
Quartararo, LG .
SPINE, 2003, 28 (01) :91-97
[8]   In vitro simulation - Early results of stereotaxy for pedicle screw placement [J].
Carl, AL ;
Khanuja, HS ;
Sachs, BL ;
Gatto, CA ;
vomLehn, J ;
Vosburgh, K ;
Schenck, J ;
Lorensen, W ;
Rohling, K ;
Disler, D .
SPINE, 1997, 22 (10) :1160-1164
[9]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[10]   Computer-assisted fluoroscopic targeting system for pedicle screw insertion [J].
Choi, WW ;
Green, BA ;
Levi, ADO .
NEUROSURGERY, 2000, 47 (04) :872-878