Quantitative Imaging of Glutathione in Live Cells Using a Reversible Reaction-Based Ratiometric Fluorescent Probe

被引:156
|
作者
Jiang, Xiqian [1 ]
Yu, Yong [2 ,3 ]
Chen, Jianwei [1 ]
Zhao, Mingkun [1 ,4 ]
Chen, Hui [1 ]
Song, Xianzhou [1 ]
Matzuk, Alexander J. [1 ]
Carroll, Shaina L. [1 ]
Tan, Xiao [1 ]
Sizovs, Antons [1 ]
Cheng, Ninghui [5 ,6 ]
Wang, Meng C. [2 ,3 ]
Wang, Jin [1 ,7 ,8 ]
机构
[1] Baylor Coll Med, Dept Pharmacol, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Mol & Human Genet, Houston, TX 77030 USA
[3] Baylor Coll Med, Huffington Ctr Aging, Houston, TX 77030 USA
[4] Baylor Coll Med, Integrat Mol & Biomed Sci Grad Program, Houston, TX 77030 USA
[5] Baylor Coll Med, ARS, USDA, Children Nutr Res Ctr, Houston, TX 77030 USA
[6] Baylor Coll Med, Dept Pediat, Houston, TX 77030 USA
[7] Baylor Coll Med, Dan L Duncan Canc Ctr, Ctr Drug Discovery, Houston, TX 77030 USA
[8] Baylor Coll Med, Cardiovasc Res Inst, Houston, TX 77030 USA
关键词
HIGHLY SELECTIVE DETECTION; HYDROGEN-SULFIDE; REDOX; THIOLS; QUANTIFICATION; MITOCHONDRIA; LUMINESCENT; METABOLITES; INDUCTION; PROTEINS;
D O I
10.1021/cb500986w
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glutathione (GSH) plays an important role in maintaining redox homeostasis inside cells. Currently, there are no methods available to quantitatively assess the GSH concentration in live cells. Live cell fluorescence imaging revolutionized the field of cell biology and has become an indispensable tool in current biological studies. In order to minimize the disturbance to the biological system in live cell imaging, the probe concentration needs to be significantly lower than the analyte concentration. Because of this, any irreversible reaction-based GSH probe can only provide qualitative results within a short reaction time and will exhibit maximum response regardless of the GSH concentration if the reaction is completed. A reversible reaction-based probe with an appropriate equilibrium constant allows measurement of an analyte at much higher concentrations and, thus, is a prerequisite for GSH quantification inside cells. In this contribution, we report the first fluorescent probe-ThiolQuant Green (TQ Green)-for quantitative imaging of GSH in live cells. Due to the reversible nature of the reaction between the probe and GSH, we are able to quantify mM concentrations of GSH with TQ Green concentrations as low as 20 nM. Furthermore, the GSH concentrations measured using TQ Green in 3T3-L1, HeLa, HepG2, PANC-1, and PANC-28 cells are reproducible and well correlated with the values obtained from cell lysates. TQ Green imaging can also resolve the changes in GSH concentration in PANC-1 cells upon diethylmaleate (DEM) treatment. In addition, TQ Green can be conveniently applied in fluorescence activated cell sorting (FACS) to measure GSH level changes. Through this study, we not only demonstrate the importance of reaction reversibility in designing quantitative reaction-based fluorescent probes but also provide a practical tool to facilitate redox biology studies.
引用
收藏
页码:864 / 874
页数:11
相关论文
共 50 条
  • [31] Reaction-Based Ratiometric and Colorimetric Chemosensor for Bioimaging of Biosulfite in Live Cells, Zebrafish, and Food Samples
    He, Xiaojun
    Xu, Wei
    Ding, Feng
    Xu, Chuchu
    Li, Yahui
    Chen, Hong
    Shen, Jianliang
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2020, 68 (42) : 11774 - 11781
  • [32] A reaction-based long-wavelength fluorescent probe for Cu2+ detection and imaging in living cells
    Khac Hong Nguyen
    Hao, Yuanqiang
    Zeng, Ke
    Wei, Xiuhua
    Yuan, Suke
    Li, Fen
    Fan, Shengnan
    Xu, Maotian
    Liu, You-Nian
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2018, 358 : 201 - 206
  • [33] A tyrosinase-triggered oxidative reaction-based "Turn-on" fluorescent probe for imaging in living melanoma cells
    Li, Zhipeng
    Wang, Yi-Feng
    Zhang, Xu
    Zeng, Chengchu
    Hu, Liming
    Liang, Xing-Jie
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 : 189 - 194
  • [34] A reaction-based ratiometric fluorescent sensor for the detection of Hg(II) ions in both cells and bacteria
    Pan, Sheng-Lin
    Li, Kun
    Li, Ling-Ling
    Li, Meng-Yang
    Shi, Lei
    Liu, Yan-Hong
    Yu, Xiao-Qi
    CHEMICAL COMMUNICATIONS, 2018, 54 (39) : 4955 - 4958
  • [35] A Ratiometric Fluorescent Probe for Hypochlorite Based on a Deoximation Reaction
    Lin, Weiying
    Long, Lingliang
    Chen, Bingbing
    Tan, Wen
    CHEMISTRY-A EUROPEAN JOURNAL, 2009, 15 (10) : 2305 - 2309
  • [36] An ESIPT-based ratiometric fluorescent probe for the imaging of nitroxyl in living cells
    Lv, Hao-Ming
    Chen, Yi
    Lei, Jian
    Au, Chak-Tong
    Yin, Shuang-Feng
    ANALYTICAL METHODS, 2015, 7 (09) : 3883 - 3887
  • [37] A Reaction-based Ratiometric Fluorescent Probe with Large STOKES Shift for Cu2+ in Neat Aqueous Solution
    Wang, Biao
    Zhu, Dongjian
    Xiong, Yuhao
    Ye, Yun
    Jiang, Ying
    Xie, Wei
    Ren, Aishan
    JOURNAL OF FLUORESCENCE, 2024,
  • [38] A reaction-based carbazole-dicyanovinyl conjugated colorimetric and ratiometric fluorescent probe for selective detection of cyanide ions
    Battal, Ahmet
    Kassa, Solomon Bezabeh
    Gultekin, Nuray Altinolcek
    Tavasli, Mustafa
    Onganer, Yavuz
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 304
  • [39] Multilayer Ratiometric Fluorescent Nanomachines for Imaging mRNA in Live Cells
    Chang, Jianqiao
    Zhang, Yu
    Li, Yike
    Han, Ziwei
    Tian, Fei
    Liu, Chao
    Feng, Qiang
    Wang, Yuguang
    Sun, Jiashu
    Zhang, Lu
    SMALL METHODS, 2021, 5 (04)
  • [40] A two-photon fluorescent probe for ratiometric imaging of endogenous hypochlorous acid in live cells and tissues
    Jun, Yong Woong
    Sarkar, Sourav
    Singha, Subhankar
    Reo, Ye Jin
    Kim, Hye Rim
    Kim, Jong-Jin
    Chang, Young-Tae
    Ahn, Kyo Han
    CHEMICAL COMMUNICATIONS, 2017, 53 (78) : 10800 - 10803