Quantitative Imaging of Glutathione in Live Cells Using a Reversible Reaction-Based Ratiometric Fluorescent Probe

被引:159
作者
Jiang, Xiqian [1 ]
Yu, Yong [2 ,3 ]
Chen, Jianwei [1 ]
Zhao, Mingkun [1 ,4 ]
Chen, Hui [1 ]
Song, Xianzhou [1 ]
Matzuk, Alexander J. [1 ]
Carroll, Shaina L. [1 ]
Tan, Xiao [1 ]
Sizovs, Antons [1 ]
Cheng, Ninghui [5 ,6 ]
Wang, Meng C. [2 ,3 ]
Wang, Jin [1 ,7 ,8 ]
机构
[1] Baylor Coll Med, Dept Pharmacol, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Mol & Human Genet, Houston, TX 77030 USA
[3] Baylor Coll Med, Huffington Ctr Aging, Houston, TX 77030 USA
[4] Baylor Coll Med, Integrat Mol & Biomed Sci Grad Program, Houston, TX 77030 USA
[5] Baylor Coll Med, ARS, USDA, Children Nutr Res Ctr, Houston, TX 77030 USA
[6] Baylor Coll Med, Dept Pediat, Houston, TX 77030 USA
[7] Baylor Coll Med, Dan L Duncan Canc Ctr, Ctr Drug Discovery, Houston, TX 77030 USA
[8] Baylor Coll Med, Cardiovasc Res Inst, Houston, TX 77030 USA
关键词
HIGHLY SELECTIVE DETECTION; HYDROGEN-SULFIDE; REDOX; THIOLS; QUANTIFICATION; MITOCHONDRIA; LUMINESCENT; METABOLITES; INDUCTION; PROTEINS;
D O I
10.1021/cb500986w
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glutathione (GSH) plays an important role in maintaining redox homeostasis inside cells. Currently, there are no methods available to quantitatively assess the GSH concentration in live cells. Live cell fluorescence imaging revolutionized the field of cell biology and has become an indispensable tool in current biological studies. In order to minimize the disturbance to the biological system in live cell imaging, the probe concentration needs to be significantly lower than the analyte concentration. Because of this, any irreversible reaction-based GSH probe can only provide qualitative results within a short reaction time and will exhibit maximum response regardless of the GSH concentration if the reaction is completed. A reversible reaction-based probe with an appropriate equilibrium constant allows measurement of an analyte at much higher concentrations and, thus, is a prerequisite for GSH quantification inside cells. In this contribution, we report the first fluorescent probe-ThiolQuant Green (TQ Green)-for quantitative imaging of GSH in live cells. Due to the reversible nature of the reaction between the probe and GSH, we are able to quantify mM concentrations of GSH with TQ Green concentrations as low as 20 nM. Furthermore, the GSH concentrations measured using TQ Green in 3T3-L1, HeLa, HepG2, PANC-1, and PANC-28 cells are reproducible and well correlated with the values obtained from cell lysates. TQ Green imaging can also resolve the changes in GSH concentration in PANC-1 cells upon diethylmaleate (DEM) treatment. In addition, TQ Green can be conveniently applied in fluorescence activated cell sorting (FACS) to measure GSH level changes. Through this study, we not only demonstrate the importance of reaction reversibility in designing quantitative reaction-based fluorescent probes but also provide a practical tool to facilitate redox biology studies.
引用
收藏
页码:864 / 874
页数:11
相关论文
共 50 条
[21]   Selective Detection of the Reduced Form of Glutathione (GSH) over the Oxidized (GSSG) Form Using a Combination of Glutathione Reductase and a Tb(III)-Cyclen Maleimide Based Lanthanide Luminescent 'Switch On' Assay [J].
McMahon, Brian K. ;
Gunnlaugsson, Thorfinnur .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (26) :10725-10728
[22]   BioNumbers-the database of key numbers in molecular and cell biology [J].
Milo, Ron ;
Jorgensen, Paul ;
Moran, Uri ;
Weber, Griffin ;
Springer, Michael .
NUCLEIC ACIDS RESEARCH, 2010, 38 :D750-D753
[23]   Intracellular glutathione pools are heterogeneously concentrated [J].
Montero, Davide ;
Tachibana, Christine ;
Winther, Jakob Rahr ;
Appenzeller-Herzog, Christian .
REDOX BIOLOGY, 2013, 1 (01) :508-513
[24]  
Morgan B, 2013, NAT CHEM BIOL, V9, P119, DOI [10.1038/NCHEMBIO.1142, 10.1038/nchembio.1142]
[25]   Bioimaging of nitric oxide [J].
Nagano, T ;
Yoshimura, T .
CHEMICAL REVIEWS, 2002, 102 (04) :1235-1269
[26]   BODIPY-Based Ratiometric Fluorescent Sensor for Highly Selective Detection of Glutathione over Cysteine and Homocysteine [J].
Niu, Li-Ya ;
Guan, Ying-Shi ;
Chen, Yu-Zhe ;
Wu, Li-Zhu ;
Tung, Chen-Ho ;
Yang, Qing-Zheng .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (46) :18928-18931
[27]   Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry [J].
Nolan, Elizabeth M. ;
Lippard, Stephen J. .
ACCOUNTS OF CHEMICAL RESEARCH, 2009, 42 (01) :193-203
[28]   QZ1 and QZ2: Rapid, reversible quinoline-derivatized fluoresceins for sensing biological Zn(II) [J].
Nolan, EM ;
Jaworski, J ;
Okamoto, KI ;
Hayashi, Y ;
Sheng, M ;
Lippard, SJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (48) :16812-16823
[29]   Fluorescence Imaging of Cellular Metabolites with RNA [J].
Paige, Jeremy S. ;
Nguyen-Duc, Thinh ;
Song, Wenjiao ;
Jaffrey, Samie R. .
SCIENCE, 2012, 335 (6073) :1194-1194
[30]   FLOW CYTOMETRIC ANALYSIS OF CELL CYCLE-DEPENDENT CHANGES IN CELL THIOL LEVEL BY COMBINING A NEW LASER-DYE WITH HOECHST-33342 [J].
POOT, M ;
KAVANAGH, TJ ;
KANG, HC ;
HAUGLAND, RP ;
RABINOVITCH, PS .
CYTOMETRY, 1991, 12 (02) :184-187