Preanalytical variability in laboratory testing: influence of the blood drawing technique

被引:43
|
作者
Lippi, G [1 ]
Salvagno, GL [1 ]
Brocco, G [1 ]
Guidi, GC [1 ]
机构
[1] Univ Verona, Dipartimento Sci Morfol Biomed, Sez Chim & Microscopia Clin, I-37100 Verona, Italy
关键词
blood collection; butterfly device; laboratory testing; preanalytical variability; standardization;
D O I
10.1515/CCLM.2005.055
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The predominant technique used to draw blood for laboratory testing is a conventional straight needle attached to an evacuated tube system. However, alternative tools might be advantageous in exceptional circumstances. The use of butterfly devices has been traditionally discouraged for reasons of costs and due to the high risk of obtaining unsuitable samples but there is no convincing evidence to support the latter indication. The purpose of this study was to compare results of hematological and clinical chemistry testing, after drawing blood into evacuated tubes, employing either a traditional 21-gauge straight needle or a 21-gauge butterfly device with 300-mm-grade polyvinyl chloride tubing. Blood samples and complete sets of data were successfully obtained for 30 consecutive outpatients. Of the 43 hematological and clinical chemistry parameters measured, means for paired samples collected by the two alternative drawing techniques did not differ significantly, except for serum sodium, white blood cells and platelets counts. Bland-Altman plots and limits-of-agreement analysis showed mean bias of between -7.2% and 1.7% and relative coefficients of variation ranging from 0.2% to 21.2%. The 95% agreement interval in the set of differences was acceptable and was mostly within the current analytical quality specifications for desirable bias. The rate of hemolysis in plasma was not statistically different between the two collection techniques. Taken together, the results of the present investigation suggest that, when a proper technique is used and within certain limitations, the butterfly device may be a reliable alternative to the conventional straight needle to draw blood for laboratory testing.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 21 条
  • [11] Devices to Reduce the Volume of Blood Taken for Laboratory Testing in ICU Patients: A Systematic Review
    Siegal, Deborah M.
    Manning, Neal
    Chornenki, Nicholas L. Jackson
    Hillis, Christopher M.
    Heddle, Nancy M.
    JOURNAL OF INTENSIVE CARE MEDICINE, 2020, 35 (10) : 1074 - 1079
  • [12] Influence of mechanical trauma of blood and hemolysis on PFA-100 testing
    Lippi, Giuseppe
    Fontana, Rossana
    Avanzini, Paola
    Aloe, Rosalia
    Ippolito, Luigi
    Sandei, Franca
    Favaloro, Emmanuel J.
    BLOOD COAGULATION & FIBRINOLYSIS, 2012, 23 (01) : 82 - 86
  • [13] Thermoset thin film primers: Influence of substrate, layer thickness and wettability of additives in laboratory testing
    Wiener, Simon
    Strauss, Bernhard
    Luckeneder, Gerald
    Hagler, Josef
    Valtiner, Markus
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2023, 74 (08): : 1183 - 1195
  • [14] Laboratory erosion-corrosion testing of FBC heat exchanger materials - Influence of test parameters
    Tarkpea, P
    Engman, U
    Olsson, M
    MATERIALS AT HIGH TEMPERATURES, 1995, 13 (03) : 139 - 146
  • [15] Overcoming challenges regarding reference materials and regulations that influence global standardization of medical laboratory testing results
    Miller, W. Greg
    Myers, Gary
    Cobbaert, Christa M.
    Young, Ian S.
    Theodorsson, Elvar
    Wielgosz, Robert, I
    Westwood, Steven
    Maniguet, Stephanie
    Gillery, Philippe
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (01) : 48 - 54
  • [16] Different manufacturers of syringes: A new source of variability in blood gas, acid-base balance and related laboratory test?
    Lima-Oliveira, Gabriel
    Lippi, Giuseppe
    Salvagno, Gian Luca
    Montagnana, Martina
    Picheth, Geraldo
    Guidi, Gian Cesare
    CLINICAL BIOCHEMISTRY, 2012, 45 (09) : 683 - 687
  • [17] Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine
    Dukic, Lora
    Kopcinovic, Lara Milevoj
    Dorotic, Adrijana
    Barsic, Ivana
    BIOCHEMIA MEDICA, 2016, 26 (03) : 318 - 336
  • [18] Orbital sinus blood sampling in rats as performed by different animal technicians: the influence of technique and expertise
    van Herck, H
    Baumans, V
    Brandt, CJWM
    Hesp, APM
    Sturkenboom, JH
    van Lith, HA
    van Tintelen, G
    Beynen, AC
    LABORATORY ANIMALS, 1998, 32 (04) : 377 - 386
  • [19] Influence of the needle bore size used for collecting venous blood samples on routine clinical chemistry testing
    Lippi, Giuseppe
    Salvagno, Gian Luca
    Montagnana, Martina
    Brocco, Giorgio
    Guidi, Gian Cesare
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (08) : 1009 - 1014
  • [20] Evaluation of the GEM® Premier™ 4000:: a compact blood gas CO-Oximeter and electrolyte analyzer for point-of-care and laboratory testing
    Beneteau-Burnat, Benedicte
    Pernet, Pascal
    Pilon, Antoine
    Latour, Damien
    Goujon, Stephanie
    Feuillu, Alain
    Vaubourdolle, Michel
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (02) : 271 - 279