Preanalytical variability in laboratory testing: influence of the blood drawing technique

被引:43
|
作者
Lippi, G [1 ]
Salvagno, GL [1 ]
Brocco, G [1 ]
Guidi, GC [1 ]
机构
[1] Univ Verona, Dipartimento Sci Morfol Biomed, Sez Chim & Microscopia Clin, I-37100 Verona, Italy
关键词
blood collection; butterfly device; laboratory testing; preanalytical variability; standardization;
D O I
10.1515/CCLM.2005.055
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The predominant technique used to draw blood for laboratory testing is a conventional straight needle attached to an evacuated tube system. However, alternative tools might be advantageous in exceptional circumstances. The use of butterfly devices has been traditionally discouraged for reasons of costs and due to the high risk of obtaining unsuitable samples but there is no convincing evidence to support the latter indication. The purpose of this study was to compare results of hematological and clinical chemistry testing, after drawing blood into evacuated tubes, employing either a traditional 21-gauge straight needle or a 21-gauge butterfly device with 300-mm-grade polyvinyl chloride tubing. Blood samples and complete sets of data were successfully obtained for 30 consecutive outpatients. Of the 43 hematological and clinical chemistry parameters measured, means for paired samples collected by the two alternative drawing techniques did not differ significantly, except for serum sodium, white blood cells and platelets counts. Bland-Altman plots and limits-of-agreement analysis showed mean bias of between -7.2% and 1.7% and relative coefficients of variation ranging from 0.2% to 21.2%. The 95% agreement interval in the set of differences was acceptable and was mostly within the current analytical quality specifications for desirable bias. The rate of hemolysis in plasma was not statistically different between the two collection techniques. Taken together, the results of the present investigation suggest that, when a proper technique is used and within certain limitations, the butterfly device may be a reliable alternative to the conventional straight needle to draw blood for laboratory testing.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 21 条
  • [1] Preanalytical variability: the dark side of the moon in laboratory testing
    Lippi, G
    Guidi, GC
    Mattiuzzi, C
    Plebani, M
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (04) : 358 - 365
  • [2] Risk management in the preanalytical phase of laboratory testing
    Lippi, Giuseppe
    Guidi, Gian Cesare
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (06) : 720 - 727
  • [3] Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing
    Lima-Oliveira, Gabriel
    Lippi, Giuseppe
    Salvagno, Gian Luca
    Montagnana, Martina
    Picheth, Geraldo
    Guidi, Gian Cesare
    BLOOD COAGULATION & FIBRINOLYSIS, 2013, 24 (03) : 252 - 255
  • [4] Determining the minimum blood volume required for laboratory testing in newborns
    Cadamuro, Janne
    Wald, Martin
    Mrazek, Cornelia
    Giesriegl, Florian
    Mink, Sylvia
    Weghuber, Daniel
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,
  • [5] Technical Evaluation of the Novel Preanalytical Module on Instrumentation Laboratory ACL TOP: Advancing Automation in Hemostasis Testing
    Lippi, Giuseppe
    Ippolito, Luigi
    Favaloro, Emmanuel J.
    JALA, 2013, 18 (05): : 382 - 390
  • [6] Implementation of a proficiency testing for the assessment of the preanalytical phase of blood samples used for RNA based analysis
    Guenther, Kalle
    Malentacchi, Francesca
    Verderio, Paolo
    Pizzamiglio, Sara
    Ciniselli, Chiara Maura
    Tichopad, Ales
    Kubista, Mikael
    Wyrich, Ralf
    Pazzagli, Mario
    Gelmini, Stefania
    CLINICA CHIMICA ACTA, 2012, 413 (7-8) : 779 - 786
  • [7] Preanalytical Impact of Incomplete K2EDTA Blood Tube Filling in Molecular Biology Testing
    Benati, Marco
    Pighi, Laura
    Paviati, Elisa
    Visconti, Sara
    Lippi, Giuseppe
    Salvagno, Gian Luca
    DIAGNOSTICS, 2024, 14 (17)
  • [8] Influence of Hemolysis on Routine Laboratory Cardiac Marker Testing
    Daves, Massimo
    Salvagno, Gian Luca
    Cemin, Roberto
    Gelati, Matteo
    Cervellin, Gianfranco
    Guidi, Gian Cesare
    Lippi, Giuseppe
    CLINICAL LABORATORY, 2012, 58 (3-4) : 333 - 336
  • [9] Are patients well informed about the fasting requirements for laboratory blood testing?
    Kackov, Sanja
    Simundic, Ana-Maria
    Gatti-Drnic, Ani
    BIOCHEMIA MEDICA, 2013, 23 (03) : 326 - 331
  • [10] Repeated blood collection in the laboratory mouse by tail incision - Modification of an old technique
    Durschlag, M
    Wurbel, H
    Stauffacher, M
    VonHolst, D
    PHYSIOLOGY & BEHAVIOR, 1996, 60 (06) : 1565 - 1568