Task-based assessment on various optimization protocols of computed tomography Pulmonary Angiography examination

被引:5
作者
Harun, Hanif Haspi [1 ]
Karim, Muhammad Khalis Abdul [1 ]
Muhammad, Nor Azura [1 ]
Kechik, Mohd Mustafa Awang [1 ]
Chew, Ming Tsuey [2 ]
Talib, Zainal Abidin [3 ]
机构
[1] Univ Putra Malaysia, Fac Sci, Dept Phys, Serdang 43400, Selangor, Malaysia
[2] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, 5 Jalan Univ, Petaling Jaya 47500, Selangor, Malaysia
[3] Jeonbuk Natl Univ, Coll Nat Sci, Dept Phys, 567 Baekje Daero, Jeonju Si 54896, Jeollabuk Do, South Korea
关键词
CTPA; NPS; TTF; CNR; Task-based; ITERATIVE RECONSTRUCTION ALGORITHM; CONTRAST SPATIAL-RESOLUTION; IMAGE QUALITY; CANCER-RISKS; CT; PERFORMANCE; NOISE; EMBOLISM; MDCT;
D O I
10.1016/j.radphyschem.2021.109692
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This prospective study was designed to assess CT performance by using the task-based image quality assessment and to identify the influence of iterative reconstruction (IR) algorithm, tube potential and pitch factor selection on dose and image quality during Computed Tomography Pulmonary Angiography (CTPA) examination. An image quality phantom, Catphan-600 was utilized in this study for assessing the image quality of CTPA protocols under 128-multislice CT scanner (Philips Brilliance iCT, USA). The standard CTPA protocols were altered on its tube potential, pitch factor and iterative reconstruction algorithm (IR). Three different levels of iDose, an IR algorithm were measured in this study. The result was presented in term of signal to noise ratio (SNR), contrast to noise ratio (CNR), noise power spectrum (NPS) and target transfer function (TTF). A massive improvement of the CNR and distortion of noise texture were observed with increasing the IR algorithm level. Noise value reduction was significantly achieved by increasing the tube potential selection although there are no changes in TTF values. The alteration of pitch factor provides some fluctuation on both NPS and TTF values. In conclusion, the task -based measurement was performed, and this technique allow for characterizing the image quality with a different type of quantitative measurement for local CTPA protocols.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Optimization of the Parameters for the Test Bolus Technique in Computed Tomography Angiography of Head and Neck
    Zeng, Yuli
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (02) : 257 - 263
  • [42] The diagnostic yield for computed tomography pulmonary angiography in patients with anticoagulation
    Chatta, Payush
    Diep, Brian
    Kewcharoen, Jakrin
    Rossie, Daniel
    Toomasian, Cory
    Parwani, Purvi
    Abramov, Dmitry
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2024, 15 (04) : 251 - 255
  • [43] Simultaneous bilateral contrast injection in computed tomography pulmonary angiography
    Bulla, Stefan
    Pache, Gregor
    Bley, Thorsten
    Langer, Mathias
    Blanke, Philipp
    ACTA RADIOLOGICA, 2012, 53 (01) : 69 - 75
  • [44] Task-based assessment for radiation dose optimization in CT abdominal examinations: A phantom study
    Halim, Esnu
    Kechik, Mohd Mustafa Awang
    Ibahim, Mohamad Johari
    Harun, Hanif Haspi
    Shaffiq, Said Mohd
    Yusof, Aimi Adibah
    Karim, Muhammad Khalis Abdul
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [45] Acute Pulmonary Embolism: Prognostic Role of Computed Tomography Pulmonary Angiography (CTPA)
    Zantonelli, Giulia
    Cozzi, Diletta
    Bindi, Alessandra
    Cavigli, Edoardo
    Moroni, Chiara
    Luvara, Silvia
    Grazzini, Giulia
    Danti, Ginevra
    Granata, Vincenza
    Miele, Vittorio
    TOMOGRAPHY, 2022, 8 (01) : 529 - 539
  • [46] Comparison of computed tomography pulmonary angiography and point-of-care tests for pulmonary thromboembolism diagnosis in dogs
    Goggs, R.
    Chan, D. L.
    Benigni, L.
    Hirst, C.
    Kellett-Gregory, L.
    Fuentes, V. L.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2014, 55 (04) : 190 - 197
  • [47] Ventilation perfusion scan or computed tomography pulmonary angiography for the detection of pulmonary embolism?
    Hitchen, Sophy
    James, Jacqueline
    Thachil, Jecko
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2016, 32 : E26 - E27
  • [48] Examination of the optimal temporal resolution required for computed tomography coronary angiography
    Ohashi K.
    Ichikawa K.
    Hara M.
    Kawai T.
    Kunitomo H.
    Higashide R.
    Shibamoto Y.
    Radiological Physics and Technology, 2013, 6 (2) : 453 - 460
  • [49] Computed tomography-based visual assessment of chronic obstructive pulmonary disease: comparison with pulmonary function test and quantitative computed tomography
    Kang, Han Sol
    Bak, So Hyeon
    Oh, Ha Yeun
    Lim, Myoung-Nam
    Cha, Yoon Ki
    Yoon, Hyun Jung
    Kim, Woo Jin
    JOURNAL OF THORACIC DISEASE, 2021, 13 (03) : 1495 - 1506
  • [50] CT iterative reconstruction algorithms: a task-based image quality assessment
    Greffier, J.
    Frandon, J.
    Larbi, A.
    Beregi, J. P.
    Pereira, F.
    EUROPEAN RADIOLOGY, 2020, 30 (01) : 487 - 500