Task-based assessment on various optimization protocols of computed tomography Pulmonary Angiography examination

被引:5
|
作者
Harun, Hanif Haspi [1 ]
Karim, Muhammad Khalis Abdul [1 ]
Muhammad, Nor Azura [1 ]
Kechik, Mohd Mustafa Awang [1 ]
Chew, Ming Tsuey [2 ]
Talib, Zainal Abidin [3 ]
机构
[1] Univ Putra Malaysia, Fac Sci, Dept Phys, Serdang 43400, Selangor, Malaysia
[2] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, 5 Jalan Univ, Petaling Jaya 47500, Selangor, Malaysia
[3] Jeonbuk Natl Univ, Coll Nat Sci, Dept Phys, 567 Baekje Daero, Jeonju Si 54896, Jeollabuk Do, South Korea
关键词
CTPA; NPS; TTF; CNR; Task-based; ITERATIVE RECONSTRUCTION ALGORITHM; CONTRAST SPATIAL-RESOLUTION; IMAGE QUALITY; CANCER-RISKS; CT; PERFORMANCE; NOISE; EMBOLISM; MDCT;
D O I
10.1016/j.radphyschem.2021.109692
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This prospective study was designed to assess CT performance by using the task-based image quality assessment and to identify the influence of iterative reconstruction (IR) algorithm, tube potential and pitch factor selection on dose and image quality during Computed Tomography Pulmonary Angiography (CTPA) examination. An image quality phantom, Catphan-600 was utilized in this study for assessing the image quality of CTPA protocols under 128-multislice CT scanner (Philips Brilliance iCT, USA). The standard CTPA protocols were altered on its tube potential, pitch factor and iterative reconstruction algorithm (IR). Three different levels of iDose, an IR algorithm were measured in this study. The result was presented in term of signal to noise ratio (SNR), contrast to noise ratio (CNR), noise power spectrum (NPS) and target transfer function (TTF). A massive improvement of the CNR and distortion of noise texture were observed with increasing the IR algorithm level. Noise value reduction was significantly achieved by increasing the tube potential selection although there are no changes in TTF values. The alteration of pitch factor provides some fluctuation on both NPS and TTF values. In conclusion, the task -based measurement was performed, and this technique allow for characterizing the image quality with a different type of quantitative measurement for local CTPA protocols.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Adherence to risk-assessment protocols to guide computed tomography pulmonary angiography in patients with suspected pulmonary embolism
    Kauppi, Juha Matias
    Airaksinen, K. E. Juhani
    Saha, Juuso
    Bondfolk, Anton
    Pouru, Jussi-Pekka
    Purola, Petra
    Jaakkola, Samuli
    Lehtonen, Jarmo
    Vasankari, Tuija
    Juonala, Markus
    Kiviniemi, Tuomas
    EUROPEAN HEART JOURNAL-QUALITY OF CARE AND CLINICAL OUTCOMES, 2022, 8 (04) : 461 - 468
  • [2] Optimization of CT pulmonary angiography for pulmonary embolism using task-based image quality assessment and diagnostic reference levels: A multicentric study
    Viry, Anais
    Vitzthum, Veronika
    Monnin, Pascal
    Bize, Julie
    Rotzinger, David
    Racine, Damien
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 121
  • [3] Computed Tomography Pulmonary Angiography: An Assessment of the Radiology Report
    Abujudeh, Hani H.
    Kaewlai, Rathachai
    Farsad, Khashayar
    Orr, Esther
    Gilman, Matthew
    Shepard, Jo-Anne O.
    ACADEMIC RADIOLOGY, 2009, 16 (11) : 1309 - 1315
  • [4] Optimization of computed tomography pulmonary angiography protocols using 3D printed model with simulation of pulmonary embolism
    Aldosari, Sultan
    Jansen, Shirley
    Sun, Zhonghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (01) : 53 - 62
  • [5] Predicting pulmonary hypertension with standard computed tomography pulmonary angiography
    Spruijt, Onno A.
    Bogaard, Harm-Jan
    Heijmans, Martijn W.
    Lely, Rutger J.
    van de Veerdonk, Marielle C.
    de Man, Frances S.
    Westerhof, Nico
    Vonk-Noordegraaf, Anton
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (04): : 871 - 879
  • [6] Detection of severe pulmonary hypertension based on computed tomography pulmonary angiography
    Granot, Yoav
    Rozenbaum, Zach
    Ziv-Baran, Tomer
    Berliner, Shlomo
    Adam, Sharon Z.
    Topilsky, Yan
    Aviram, Galit
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (08): : 2577 - 2588
  • [7] Detection of severe pulmonary hypertension based on computed tomography pulmonary angiography
    Yoav Granot
    Zach Rozenbaum
    Tomer Ziv-Baran
    Shlomo Berliner
    Sharon Z. Adam
    Yan Topilsky
    Galit Aviram
    The International Journal of Cardiovascular Imaging, 2021, 37 : 2577 - 2588
  • [8] Computed Tomography Pulmonary Angiography during Pregnancy: Radiation Dose of Commonly Used Protocols and the Effect of Scan Length Optimization
    Hendriks, Babs M. F.
    Schnerr, Roald S.
    Milanese, Gianluca
    Jeukens, Cecile R. L. P. N.
    Niesen, Sandra
    Eijsvoogel, Nienke G.
    Wildberger, Joachim E.
    Das, Marco
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (02) : 313 - 322
  • [9] Dose Reduction of 69% for Computed Tomography Pulmonary Angiography: Reduced z-Axis Computed Tomography Pulmonary Angiography Retains Accuracy in Those Younger Than 40 Years
    Shahir, Kaushik
    Goodman, Lawrence R.
    Lam, Cesar A.
    Midia, Esin Cakmakci
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (05) : 765 - 769
  • [10] Basic Concepts of Contrast Injection Protocols for Coronary Computed Tomography Angiography
    Oda, Seitaro
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Kidoh, Masafumi
    Funama, Yoshinori
    Tsujita, Kenichi
    Yamashita, Yasuyuki
    CURRENT CARDIOLOGY REVIEWS, 2019, 15 (01) : 24 - 29