Treatment response evaluation with three-dimensional contrast-enhanced ultrasound for liver cancer after local therapies

被引:31
作者
Xu, Hui-Xiong [1 ]
Lu, Ming-De [2 ]
Xie, Xiao-Hua [1 ]
Xie, Xiao-Yan [1 ]
Kuang, Ming [2 ]
Xu, Zuo-Feng [1 ]
Liu, Guang-Jian [1 ]
Wang, Zhu [1 ]
Chen, Li-Da [1 ]
Lin, Man-Xia [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Hepatobiliary Surg, Guangzhou 510080, Guangdong, Peoples R China
关键词
Three-dimensional ultrasound; Contrast-enhanced ultrasound; Hepatocellular carcinoma; Liver cancer; Treatment response; Ablation; PERCUTANEOUS THERMAL ABLATION; HEPATOCELLULAR-CARCINOMA; SONOGRAPHY; ULTRASONOGRAPHY; FEASIBILITY; TUMORS;
D O I
10.1016/j.ejrad.2009.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the potential usefulness of three-dimensional contrast-enhanced ultrasound (3D-CEUS) in evaluating the treatment response for liver cancer after local therapies. Methods: A total of 107 lesions in 95 consecutive patients with liver cancer underwent local therapies and thereafter received low acoustic power 3D-CEUS examination. The LOGIQ 9 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The image quality of 3D-CEUS images was evaluated and the influence of 3D-CEUS to clinical outcome was investigated. Results: The image quality of 3D-CEUS was defined as high in 102 (102/107, 95.3%) lesions and common in 5 (5/107, 4.7%) lesions. 3D-CEUS did not change the diagnosis in any patient compared with 2D-CEUS. However, 3D-CEUS changed the management in 3 (2.8%) of 107 lesions, increased confidence but made no change in diagnosis in 85 (79.5%) lesions, added some information but did not change management or diagnosis in 15 (14.0%), and made no change in 4 (3.7%), respectively, in comparison with 2D-CEUS. Conclusion: 3D-CEUS enhances the diagnostic confidence in the majority of the patients and even changes the management in some patients. 3D-CEUS has potential usefulness in evaluating treatment response for liver cancer after local therapies. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 20 条
[1]   Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data [J].
Beller, Siegfried ;
Huenerbein, Michael ;
Eulenstein, Sebastian ;
Lange, Thomas ;
Schlag, Peter M. .
ANNALS OF SURGERY, 2007, 246 (02) :288-294
[2]   Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) -: Update 2008 [J].
Claudon, M. ;
Cosgrove, D. ;
Albrecht, T. ;
Bolondi, L. ;
Bosio, M. ;
Calliada, F. ;
Correas, J. -M. ;
Darge, K. ;
Dietrich, C. ;
D'Onofrio, M. ;
Evans, D. H. ;
Filice, C. ;
Greiner, L. ;
Jaeger, K. ;
de Jong, N. ;
Leen, E. ;
Lencioni, R. ;
Lindsell, D. ;
Martegani, A. ;
Meairs, S. ;
Nolsoe, C. ;
Piscaglia, F. ;
Ricci, P. ;
Seidel, G. ;
Skjoldbye, B. ;
Solbiati, L. ;
Thorelius, L. ;
Tranquart, F. ;
Weskott, H. P. ;
Whittingham, T. .
ULTRASCHALL IN DER MEDIZIN, 2008, 29 (01) :28-44
[3]   3D real time contrast enhanced ultrasonography, an new technique [J].
Dietrich, CF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (02) :160-163
[4]   Contrast enhanced vascular three-dimensional ultrasound imaging [J].
Forsberg, F ;
Rawool, NM ;
Merton, DA ;
Liu, JB ;
Goldberg, BB .
ULTRASONICS, 2002, 40 (1-8) :117-122
[5]   Image-Guided Tumor Ablation: Standardization of terminology and reporting criteria [J].
Goldberg, SN ;
Grassi, CJ ;
Cardella, JF ;
Charboneau, JW ;
Dodd, GD ;
Dupuy, DE ;
Gervais, D ;
Gillams, AR ;
Kane, RA ;
Lee, FT ;
Livraghi, T ;
McGahan, J ;
Phillips, DA ;
Rhim, H ;
Silverman, SG .
RADIOLOGY, 2005, 235 (03) :728-739
[6]   Comparison of contrast enhanced ultrasound and contrast enhanced CT or MRI in monitoring percutaneous thermal ablation procedure in patients with hepatocellular carcinoma: A multi-center study in China [J].
Lu, Ming-De ;
Yu, Xiao-Ling ;
Li, An-Hua ;
Jiang, Tian-An ;
Chen, Min-Hua ;
Zhao, Bao-Zhen ;
Zhou, Xiao-Dong ;
Wang, Jin-Rui .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (11) :1736-1749
[7]  
LUO W, 2008, EUR J RADIOL
[8]   Harmonic gray scale 3D contrast imaging of the liver [J].
Moriyasu, F ;
Migihashi, R ;
Matsumura, T ;
Toda, Y ;
Chiba, T .
ACADEMIC RADIOLOGY, 2002, 9 :S228-S230
[9]   Three-dimensional ultrasound imaging [J].
Nelson, TR ;
Pretorius, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) :1243-1270
[10]   Vascular flow patterns of hepatic tumors in contrast-enhanced 3-dimensional fusion ultrasonography using plane shift and opacity control modes [J].
Ohto, M ;
Kato, H ;
Tsujii, H ;
Maruyama, H ;
Matsutani, S ;
Yamagata, H .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (01) :49-57