NICKEL-TITANIUM WIRE AS A FLEXOR TENDON SUTURE MATERIAL: AN EX VIVO STUDY

被引:13
|
作者
Karjalainen, T. [1 ]
Goransson, H.
Viinikainen, A.
Jamsa, T.
Ryhanen, J.
机构
[1] Oulu Univ Hosp, Dept Surg, FIN-90029 Oulu, Finland
关键词
biomechanical testing; braided polyester; flexor tendon repair; nickel-titanium alloy; suture; MEMORY ALLOY SUTURE; SHAPE-MEMORY; ZONE-II; REPAIR; MOBILIZATION; STRENGTH; 4-STRAND; MOTION; PURCHASE;
D O I
10.1177/1753193409347421
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Nickel-titanium shape memory alloy ( NiTi) is a new suture material that is easy to handle, is strong, and biocompatible. The purpose of this study was to evaluate the material properties and biomechanical behaviour of 150 mu m and 200 mu m NiTi wires in flexor tendon repair. Braided polyester (4-0 Ethibond (R)) was used as control. Fifty fresh-frozen porcine flexor tendons were repaired using the Pennington modification of the Kessler repair or a double Kessler technique. NiTi wires were stiffer and reached higher tensile strength compared to braided polyester suture. Repairs with 200 mu m NiTi wire had a higher yield force, ultimate force and better resistance to gapping than 4-0 braided polyester repairs. Repairs made with 200 mu m NiTi wire achieved higher stiffness and ultimate force than repairs made with 150 mu m NiTi wire.
引用
收藏
页码:469 / 474
页数:6
相关论文
共 50 条
  • [1] Nickel-Titanium Wire in Circumferential Suture of a Flexor Tendon Repair: A Comparison to Polypropylene
    Karjalainen, T.
    He, M.
    Chong, A. K. S.
    Lim, A. Y. T.
    Ryhanen, J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (07): : 1160 - 1164
  • [2] Nickel-Titanium Wire as Suture Material: A New Technique for the Fixation of Skin
    Li, Haidong
    Song, Tao
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (04) : E343 - E344
  • [3] Biomechanical Evaluation of Flexor Tendon Repair Using Barbed Suture Material: A Comparative ex vivo Study
    Haddad, Roger
    Peltz, Tim S.
    Walsh, William R.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (09): : 1565 - 1566
  • [4] Biomechanical Evaluation of Flexor Tendon Repair Using Barbed Suture Material: A Comparative Ex Vivo Study
    Zeplin, Philip H.
    Zahn, Robert K.
    Meffert, Rainer H.
    Schmidt, Karsten
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (03): : 446 - 449
  • [5] DMTA study of a nickel-titanium wire
    Artiaga, R
    García, A
    García, L
    Varela, A
    Mier, JL
    Naya, S
    Graña, M
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2002, 70 (01): : 199 - 207
  • [6] DMTA study of a nickel-titanium wire
    R. Artiaga
    A. Garcia
    L. Garcia
    A. Varela
    J. L. Mier
    S. Naya
    M. Grana
    Journal of Thermal Analysis and Calorimetry, 2002, 70 : 199 - 207
  • [7] Tensile Strength of Flexor Tendon Repair Using Barbed Suture Material in a Dynamic Ex Vivo Model
    Zeplin, Philip H.
    Henle, M.
    Zahn, R. K.
    Meffert, R. H.
    Schmidt, K.
    JOURNAL OF HAND AND MICROSURGERY, 2012, 4 (01) : 16 - 20
  • [8] GEOMETRIC AND MATERIAL PARAMETERS OF A NICKEL-TITANIUM AND A BETA-TITANIUM ORTHODONTIC ARCH WIRE ALLOY
    KUSY, RP
    STUSH, AM
    DENTAL MATERIALS, 1987, 3 (04) : 207 - 217
  • [9] Flexor tendon repair with a polytetrafluoroethylene (PTFE) suture material
    Polykandriotis, Elias
    Besrour, Foued
    Arkudas, Andreas
    Ruppe, Florian
    Zetzmann, Katharina
    Braeuer, Lars
    Horch, Raymund E.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (03) : 429 - 434
  • [10] Flexor tendon repair with a polytetrafluoroethylene (PTFE) suture material
    Elias Polykandriotis
    Foued Besrour
    Andreas Arkudas
    Florian Ruppe
    Katharina Zetzmann
    Lars Braeuer
    Raymund E. Horch
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 429 - 434