Depiction of the native coronary arteries during ECG-triggered High-Pitch Dual-Source Coronary Computed Tomography Angiography in children: Determinants of image quality

被引:4
作者
Barrera, Christian A. [1 ]
Otero, Hansel J. [1 ]
White, Ammie M. [1 ]
Saul, David [1 ]
Biko, David M. [1 ]
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, 34th St & Civ Ctr Blvd, Philadelphia, PA 19104 USA
关键词
Children; Dual-source CT; Coronary arteries; High pitch; ECG-triggered; Cardiac CT; CONGENITAL HEART-DISEASE; SOURCE CT ANGIOGRAPHY; PEDIATRIC-PATIENTS; YOUNG-CHILDREN; INFANTS; FEASIBILITY; VISIBILITY; ANOMALIES; ACCURACY; EFFICACY;
D O I
10.1016/j.clinimag.2018.08.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Assess the image quality of ECG-triggered High-Pitch Dual-Source CTA for the evaluation of native coronaries in children. Materials and methods: Between August 2014 and September 2017, 45 children with morphologically normal cardiac chambers had cardiac prospective ECG-triggered High-Pitch Dual-Source CTA. Two pediatric radiologists blinded to clinical data, independently reviewed each case. The coronary arteries were evaluated using a four-point scale quality score according to the coronary segment. Attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured using values from the air, inter-ventricular septum and ascending aorta at the level of the sinuses of Valsalva. Results: 225 coronary segments were assessed showed a mean score of 2.40 +/- 0.73, 94.2% had diagnostic image quality. The best and worst average quality were seen in segment 5 and 2, respectively. Inter-observer agreement was moderate for all segments except for segment 1, which was excellent. Worse quality scores were significantly associated with younger patients and low body mass index as well as with higher heart rates in all segments. The mean observed heart rate and BSA in patients with diagnostic image quality were below 77 bpm and over 1.4 m(2) respectively. There is no significant association between attenuation, SNR and CNR with image quality. Conclusions: Prospective ECG-triggered High-Pitch Dual-Source Computed Tomography Angiography achieves consistent and diagnostic image quality for coronary artery assessment at a low effective dose in pediatric patients.
引用
收藏
页码:240 / 245
页数:6
相关论文
共 49 条
[1]   Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[2]  
[Anonymous], 2008, AAPM REP, DOI DOI 10.37206/97
[3]  
[Anonymous], CIRCULATION
[4]   Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography [J].
Apfaltrer, Paul ;
Sudarski, Sonja ;
Schneider, David ;
Nance, John W., Jr. ;
Haubenreisser, Holger ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :322-328
[5]   Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography [J].
Araoz, Philip A. ;
Kirsch, Jacobo ;
Primak, Andrew N. ;
Braun, Natalie N. ;
Saba, Osama ;
Williamson, Eric E. ;
Harmsen, W. Scott ;
Mandrekar, Jayawant N. ;
McCollough, Cynthia H. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08) :837-845
[6]   CORONARY-ARTERY CALIBER IN NORMAL-CHILDREN AND PATIENTS WITH KAWASAKI-DISEASE BUT WITHOUT ANEURYSMS - AN ECHOCARDIOGRAPHIC AND ANGIOGRAPHIC STUDY [J].
ARJUNAN, K ;
DANIELS, SR ;
MEYER, RA ;
SCHWARTZ, DC ;
BARRON, H ;
KAPLAN, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (05) :1119-1124
[7]   Introduction to cardiac imaging in infants and children: Techniques, potential, and role in the imaging work-up of various cardiac malformations and other pediatric heart conditions [J].
Bailliard, Frederique ;
Hughes, Marina L. ;
Taylor, Andrew M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (02) :191-198
[8]   Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease [J].
Ben Saad, Moez ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Adler, Ghazal ;
Paul, Jean-Francois .
PEDIATRIC RADIOLOGY, 2009, 39 (07) :668-676
[9]   Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[10]   Noninvasive coronary artery Imaging - Magnetic resonance angiography and multidetector computed tomography angiography - A scientific statement from the American Heart Association Committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention, and the councils on clinical cardiology and cardiovascular disease in the young [J].
Bluemke, David A. ;
Achenbach, Stephan ;
Budoff, Matthew ;
Gerber, Thomas C. ;
Gersh, Bernard ;
Hillis, L. David ;
Hundley, W. Gregory ;
Manning, Warren J. ;
Printz, Beth Feller ;
Stuber, Matthias ;
Woodard, Pamela K. .
CIRCULATION, 2008, 118 (05) :586-606