Spoilage Detection with Biogenic Amine Biosensors, Comparison of Different Enzyme Electrodes

被引:63
作者
Boka, Beata [1 ]
Adanyi, Nora [2 ]
Virag, Diana [1 ]
Sebela, Marek [3 ]
Kiss, Attila [1 ]
机构
[1] Eszterhazy Karoly Coll, EGERFOOD Reg Knowledge Ctr, H-3300 Eger, Hungary
[2] Cent Food Res Inst, H-1022 Budapest, Hungary
[3] Palacky Univ, Dept Biochem, CZ-78371 Olomouc, Czech Republic
关键词
Biosensors; Electrochemistry; Enzymes; Meat freshness; Amine oxidases; AMPEROMETRIC BIOSENSOR; METHYLAMINE DEHYDROGENASE; PUTRESCINE OXIDASE; FISH QUALITY; SENSOR; HISTAMINE; FRESHNESS; CHICKEN;
D O I
10.1002/elan.201100419
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three enzyme based amperometric biosensors for biogenic amines were applied for meat spoilage monitoring. With diamine oxidase (EC 1.4.3.6), the total biogenic amine content was measured. Monoamine oxidase A (EC 1.4.3.4) was used for determination of tyramine, tryptamine and phenylethylamine content. Putrescine was selectively detected with putrescine oxidase (EC 1.4.3.10). The enzymes were separately co-immobilized on graphite electrodes with peroxidase and Os mediator (PVI7-dme-Os). A fast extraction method using special centrifugal separator was applied for pork and fish samples stored at different conditions. Although partial extraction was achieved, the results correlate with total biogenic amine content measured by HPLC method.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 27 条
[1]  
[Anonymous], 2005, OFFIC J EUROP UNIO L, VL 338, P1
[2]  
[Anonymous], 2001, Fish and fisheries products hazards and controls guidance
[3]   Disposable biosensors for determination of biogenic amines [J].
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Matos, Patricia ;
Julia Arcos-Martinez, M. .
ANALYTICA CHIMICA ACTA, 2010, 665 (01) :26-31
[4]   Improved sensitivity of a histamine sensor using an engineered methylamine dehydrogenase [J].
Bao, LL ;
Sun, DP ;
Tachikawa, H ;
Davidson, VL .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1144-+
[5]   An interference free amperometric biosensor for the detection of biogenic amines in food products [J].
Carelli, Donatella ;
Centonze, Diego ;
Palermo, Carmen ;
Quinto, Maurizio ;
Rotunno, Taddeo .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (05) :640-647
[6]   Diamine oxidase and putrescine oxidase immobilized reactors in flow injection analysis: a comparison in substrate specificity [J].
Carsol, MA ;
Mascini, M .
TALANTA, 1999, 50 (01) :141-148
[7]   Development of screen-printed enzyme electrodes for the estimation of fish quality [J].
Chemnitius, GC ;
Bilitewski, U .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (02) :107-113
[8]  
DESA RJ, 1972, J BIOL CHEM, V247, P5527
[9]   Determination of biogenic amines with an electrochemical biosensor and its application to salted anchovies [J].
Draisci, R ;
Volpe, G ;
Lucentini, L ;
Cecilia, A ;
Federico, R ;
Palleschi, G .
FOOD CHEMISTRY, 1998, 62 (02) :225-232
[10]   Amine oxidase-based flow biosensor for the assessment of fish freshness [J].
Frébort, I ;
Skoupá, L ;
Pec, P .
FOOD CONTROL, 2000, 11 (01) :13-18