Evaluation of control parameters' effects on system performance with Taguchi method in waste heat recovery application using mechanical heat pump

被引:19
作者
Coskun, Salih [2 ]
Motorcu, Ali Riza [1 ]
Yamankaradeniz, Nurettin [2 ]
Pulat, Erhan [3 ]
机构
[1] Canakkale Onsekiz Mart Univ, Fac Engn & Architecture, Dept Ind Engn, TR-17100 Canakkale, Turkey
[2] Uludag Univ, Vocat Sch Tech Sci, Elect & Energy Dept, Air Conditioning & Refrigerat Program, TR-16059 Gorukle, Turkey
[3] Uludag Univ, Fac Engn & Architecture, Dept Mech Engn, TR-16059 Gorukle, Turkey
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2012年 / 35卷 / 04期
关键词
Heat pump; Heat recovery; Mechanical vapor compression; Wastewater; Waste heat; Taguchi; OPTIMUM WORKING-CONDITIONS; INDUSTRY; OPTIMIZATION;
D O I
10.1016/j.ijrefrig.2011.12.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with an investigation of the effect and optimization of control parameters on the system performance in waste heat recovery application using mechanical heat pump (MHP). The experimental studies have been conducted under varying compressor speed, wastewater temperature and flow rate. The experiments have been planned based on Taguchi's L27 orthogonal array with each trial performed under different conditions of compressor's speed, wastewater temperature and flow rate. The optimum parameter combination has been obtained by using the analysis of signal-to-noise (S/N) ratio. The level of importance of the control parameters on the system performance has been determined by using analysis of variance (ANOVA). Main effects plots and interaction effects plots have been utilized to optimize and analyze the relation between the control parameters and the system performance. The results obtained from Taguchi method were also compared with ANN results. The experimental study indicated that it is possible to increase system performance significantly in the waste heat recovery application using MHP. (C) 2011 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:795 / 809
页数:15
相关论文
共 22 条
  • [1] On the robustness, effectiveness and reliability of chemical and mechanical heat pumps for low-temperature heat source district heating: A comparative simulation-based analysis and evaluation
    Ajah, A. N.
    Mesbah, A.
    Grievink, J.
    Herder, P. M.
    Falcao, P. W.
    Wennekes, S.
    [J]. ENERGY, 2008, 33 (06) : 908 - 929
  • [2] RECOVERY AND UTILIZATION OF WASTE HEAT
    ALRABGHI, OM
    BEIRUTTY, M
    AKYURT, M
    NAJJAR, Y
    ALP, T
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (05): : 463 - 470
  • [3] A study on the design and analysis of a heat pump heating system using wastewater as a heat source
    Baek, NC
    Shin, UC
    Yoon, JH
    [J]. SOLAR ENERGY, 2005, 78 (03) : 427 - 440
  • [4] Bendell A., 1989, TAGUCHI METHODS
  • [5] Can M., 1995, EKOLOJI, V17, P22
  • [6] Determination of optimum working conditions R22 and R404A refrigerant mixtures in heat-pumps using Taguchi method
    Comakli, K.
    Simsek, F.
    Comakli, O.
    Sahin, B.
    [J]. APPLIED ENERGY, 2009, 86 (11) : 2451 - 2458
  • [7] Determination of optimum working conditions in heat-pumps using nonazeotropic refrigerant mixtures
    Çomakli, Ö
    Çelik, C
    Erdogan, S
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (02) : 193 - 203
  • [8] Optimal utilization of waste heat from heat engines by use of a heat pump
    El-Din, MMS
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (09) : 937 - 949
  • [9] Esme U, 2009, ARAB J SCI ENG, V34, P519
  • [10] Huang K., 2006, RENEW ENERGY RESOUR, V8, P1