Noncontrast MR angiography for supraaortic arteries using inflow enhanced inversion recovery fast spin echo imaging

被引:12
作者
Takei, Naoyuki [1 ]
Miyoshi, Mitsuharu [1 ]
Kabasawa, Hiroyuki [1 ]
机构
[1] GE Healthcare, Appl Sci Lab, Tokyo, Japan
关键词
noncontrast MRA; fast spin echo; inversion pulse; supraaortic arteries; STATE FREE-PRECESSION; EXPERIENCE; SSFP;
D O I
10.1002/jmri.23515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To depict supraaortic arteries using (3D fast spin echo (FSE) combined with slab selective inversion recovery for noncontrast magnetic resonance angiography (MRA) in healthy volunteers, and to investigate the property of the inflow enhanced inversion recovery FSE (IFIR-FSE) for background suppression and inflow effects. Materials and Methods: IFIR-FSE with no image subtraction was used to visualize the aortic arch, subclavian arteries, carotid arteries, and vertebral arteries in 10 healthy volunteers. Simulations were performed to achieve both high background suppression and inflow effects by adjusting the inversion time (TI) and wait time after data acquisition. The effect of inflow was investigated with TIs of 800, 1200, 1600, and 2000 msec. Contrast between artery and these background tissues were measured with scan protocols based on simulation results. Results: IFIR-FSE images showed good visualization of the supraaortic arteries and allowed separation of arteries from veins without image subtraction. The proposed method demonstrated that a high contrast between arteries and background tissues can be acquired with various TIs, which was in good agreement with the simulation. A TI over 1600 msec was favorable in terms of background suppression, arterial signal intensity, and inflow effects. Conclusion: Inflow enhanced inversion recovery cardiac-triggered 3D FSE imaging can be used for supraaortic artery imaging without contrast agents.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 18 条
  • [1] Bernstein MA, 2001, MAGNET RESON MED, V46, P955, DOI 10.1002/mrm.1282
  • [2] Berstein MA, 2004, HDB MRI PULSE SEQUEN
  • [3] Non-contrast-Enhanced Flow-Independent Peripheral MR Angiography with Balanced SSFP
    Cukur, Tolga
    Lee, Jin H.
    Bangerter, Neal K.
    Hargreaves, Brian A.
    Nishimura, Dwight G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1533 - 1539
  • [4] DeMarco J Kevin, 2006, Magn Reson Imaging Clin N Am, V14, P109, DOI 10.1016/j.mric.2005.12.003
  • [5] MULTIPLE INVERSION RECOVERY REDUCES STATIC TISSUE SIGNAL IN ANGIOGRAMS
    DIXON, WT
    SARDASHTI, M
    CASTILLO, M
    STOMP, GP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 257 - 268
  • [6] GRADIENT MOMENT NULLING IN FAST SPIN-ECHO
    HINKS, RS
    CONSTABLE, RT
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (06) : 698 - 706
  • [7] Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion:: Initial results
    Katoh, M
    Buecker, A
    Stuber, M
    Günther, RW
    Spuentrup, E
    [J]. KIDNEY INTERNATIONAL, 2004, 66 (03) : 1272 - 1278
  • [8] Kunz P, 1999, P 7 ANN M ISMRM PHIL
  • [9] INPLANE VASCULAR IMAGING - PULSE SEQUENCE DESIGN AND STRATEGY
    LENZ, GW
    HAACKE, EM
    MASARYK, TJ
    LAUB, G
    [J]. RADIOLOGY, 1988, 166 (03) : 875 - 882
  • [10] Mark D, 2005, J MAGN RESON, V172, P306