Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography

被引:2
作者
Guo, Gang [1 ]
Yang, Yonggui [1 ]
Yang, Weiqun [1 ]
机构
[1] Fujian Med Univ, Dept Radiol, Xiamen Hosp 2, Teaching Hosp, Xiamen 361021, Fujian Province, Peoples R China
关键词
two-dimensional phase-contrast magnetic resonance angiography; blood flow; three-dimensional time-of-flight phase-contrast magnetic resonance angiography; internal carotid artery; common carotid artery; external carotid artery; velocity encoding; TIME-OF-FLIGHT; MR-ANGIOGRAPHY; INTRACRANIAL VESSELS; CEREBROSPINAL-FLUID; HYPERTENSION; MORPHOLOGY; ACCURACY; BRAIN; AORTA; AGE;
D O I
10.3969/j.issn.1673-5374.2011.30.009
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0 +/- 6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.
引用
收藏
页码:2367 / 2371
页数:5
相关论文
共 50 条
  • [31] Blood Flow Velocities as Determined by Real-Time Phase-Contrast MRI in Patients With Carotid Artery Stenosis
    Bochert, Deborah
    Hofer, Sabine
    Dechent, Peter
    Frahm, Jens
    Bahr, Mathias
    Liman, Jan
    Maier, Ilko
    JOURNAL OF NEUROIMAGING, 2025, 35 (01)
  • [32] Quantifying Hemodynamic Changes in Moyamoya Disease Based on Two-Dimensional Cine Phase-Contrast Magnetic Resonance Imaging and Computational Fluid Dynamics
    Sun, Wenbo
    Ruan, Zhao
    Dai, Xuan
    Li, Sirui
    Li, Shuo
    Zhang, Jianjian
    Chen, Jincao
    Zhang, Heye
    Xu, Haibo
    WORLD NEUROSURGERY, 2018, 120 : E1301 - E1309
  • [33] Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI
    Peng, Shin-Lei
    Shih, Cheng-Ting
    Huang, Chiun-Wei
    Chiu, Shao-Chieh
    Shen, Wu-Chung
    SCIENTIFIC REPORTS, 2017, 7
  • [34] Blood flow in cerebral aneurysms: Comparison of phase contrast magnetic resonance and computational fluid dynamics - Preliminary experience
    Karmonik, C.
    Klucznik, R.
    Benndorf, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (03): : 209 - 215
  • [35] Phase-contrast magnetic resonance flow quantification in renal arteries -: Comparison with 133Xenon washout measurements
    de Haan, MW
    van Engelshoven, JMA
    Houben, AJHM
    Kaandorp, DW
    Kessels, AGH
    Kroon, AA
    de Leeuw, PW
    HYPERTENSION, 2003, 41 (01) : 114 - 118
  • [36] Assessment of Flow and Hemodynamics in the Carotid Artery Using a Reduced TE 4D Flow Spiral Phase-Contrast MRI
    Kadbi, Mo
    Negandar, Mj
    Traughber, Melanie
    Martin, Peter
    Amini, Amir A.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1100 - 1103
  • [37] Magnetic resonance angiography for cerebral arterial and venous visualization in dogs: a comparative study of time-of-flight, phase-contrast, and time-resolved imaging of contrast kinetics sequences
    Hong, Sunghwa
    Kim, Soyeon
    Namgoong, Mire
    Kwon, Minjoo
    Yoon, Junghee
    Choi, Jihye
    FRONTIERS IN VETERINARY SCIENCE, 2025, 12
  • [38] Cervical compressive myelopathy: flow analysis of cerebrospinal fluid using phase-contrast magnetic resonance imaging
    Yun Jung Bae
    Joon Woo Lee
    Eugene Lee
    Jin S. Yeom
    Ki-Jeong Kim
    Heung Sik Kang
    European Spine Journal, 2017, 26 : 40 - 48
  • [39] Quantitative two-dimensional phase-contrast magnetic resonance imaging characterization of lower extremity venous disease: venous reflux versus venous obstruction
    Huang, Yao-Kuang
    Hsu, Yin-Chen
    Tseng, Yuan-Hsi
    Kao, Chih-Chen
    Ngo, Yeh Giin
    Lee, Chung-Yuan
    Yang, Teng-Yao
    Chang, Kuo-Song
    Chen, Pang-Yen
    Wang, Shih-Chung
    Chen, Sheng-Ya
    Lin, Yu-Hui
    Chen, Chien-Wei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 5153 - +
  • [40] Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow
    Jiang, Jingfeng
    Strother, Charles
    Johnson, Kevin
    Baker, Sara
    Consigny, Dan
    Wieben, Oliver
    Zagzebski, James
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) : 1755 - 1773