An in-situ assessment of low-density polyethylene and silicone rubber passive samplers using methods with and without performance reference compounds in the context of investigation of polychlorinated biphenyl sources in rivers

被引:11
|
作者
Estoppey, Nicolas [1 ]
Schopfer, Adrien [1 ]
Fong, Camille [2 ]
Delemont, Olivier [1 ]
De Alencastro, Luiz F. [2 ]
Esseiva, Pierre [1 ]
机构
[1] Univ Lausanne, Sch Criminal Sci, Batochime Bldg, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Cent Environm Lab, Stn 2, CH-1015 Lausanne, Switzerland
关键词
LDPE; SR; PRC; PCB; Time-weighted average (TWA) concentration; Sampling rate (R-S); SEMIPERMEABLE-MEMBRANE DEVICES; SAMPLING DEVICES; INTEGRATIVE SAMPLERS; ORGANIC-COMPOUNDS; UPTAKE RATES; WATER; SEDIMENT; PCBS; CONTAMINANTS; POLLUTANTS;
D O I
10.1016/j.scitotenv.2016.07.092
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study firstly aims to assess the field performances of low density polyethylene (LDPE) and silicone rubber (SR) samplers for the monitoring of polychlorinated biphenyls (PCBs) in water regarding the uptake, the sampling rate (R-S) estimated by using performance reference compounds (PRCs) and the time-weighted average (TWA) concentrations. The second aim is to evaluate the efficiency of these samplers to investigate PCB sources (localization and imputation steps) using methods with and without PRCs to correct for the impact of water velocity on the uptake. Samplers spiked with PRCs were deployed in the outfalls of two PCB sources and at 8 river sites situated upstream and downstream of the outfalls. After 6 weeks, the uptake of PCBs in the linear phase was equivalent in LDPE and SR but 5 times lower in LDPE for PCBs approaching equilibrium. PRC-based RS and water velocity (0.08 to 1.21 m s(-1)) were well correlated in river (LDPE: R-2 = 0.91, SR: R-2 = 0.96) but not in outfalls (higher turbulences and potential release of PRCs to air). TWA concentrations obtained with SR were slightly higher than those obtained with LDPE (factor 1.4 to 2.6 in river) likely because of uncertainty in sampler-water partition coefficient values. Concentrations obtained through filtration and extraction of water samples (203 L) were 1.6 and 5.1 times higher than TWA concentrations obtained with SR and LDPE samplers, respectively. PCB sources could efficiently be localized when PRCs were used (increases of PCB loads in river) but the impact of high differences of water velocity was overcorrected (leading sometimes to false positives and negatives). Increases of PCB loads in the river could not be entirely imputed to the investigated sources (underestimation of PCBs contributing to the load increases). A method without PRCs (relationship between uptake and water velocity) appeared to be a good complementary method for LDPE. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:794 / 803
页数:10
相关论文
共 3 条
  • [1] Low density polyethylene (LDPE) passive samplers for the investigation of polychlorinated biphenyl (PCB) point sources in rivers
    Estoppey, Nicolas
    Omlin, Julien
    Schopfer, Adrien
    Esseiva, Pierre
    Vermeirssen, Etienne L. M.
    Delemont, Olivier
    De Alencastro, Luiz F.
    CHEMOSPHERE, 2015, 118 : 268 - 276
  • [2] Spiking of performance reference compounds in low density polyethylene and silicone passive water samplers
    Booij, K
    Smedes, F
    van Weerlee, EM
    CHEMOSPHERE, 2002, 46 (08) : 1157 - 1161
  • [3] Effect of water velocity on the uptake of polychlorinated biphenyls (PCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers: An assessment of the efficiency of performance reference compounds (PRCs) in river-like flow conditions
    Estoppey, Nicolas
    Schopfer, Adrien
    Omlin, Julien
    Esseiva, Pierre
    Vermeirssen, Etienne L. M.
    Delemont, Olivier
    De Alencastro, Luiz F.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 499 : 319 - 326