DSE Stacker: Close-Packing Stacker with Double-Screw Elevating for Reagent Dispenser

被引:0
作者
Wang, Dan [1 ]
Zhang, Wenzeng [1 ]
Sun, Zhenguo [1 ]
机构
[1] Tsinghua Univ, Dept Mech Engn, Minist Educ, Key Lab Adv Mat Proc Technol, Beijing 100084, Peoples R China
来源
INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2014, PT II | 2014年 / 8918卷
关键词
Reagent dispenser; stacker system; close-packing; microplate manipulation; screw mechanism; ROBOT HAND;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Traditional stackers for reagent dispensers are complex and cumbersome in structure since the transmission systems in the chambers are as tall as the chambers storing separated microplates. This paper designs a novel close-packing stacker system with function of elevating and separating of microplates, called DSE stacker. The DSE stacker, driven by two motors, can manipulate close-packed microplates one by one in a tall chamber. The DSE stacker consists of two symmetrical screws, two stepper motors, a chamber, a carrier, and transmissions. In a DSE output stacker, the lowest microplate can be extracted, separated from upper microplates and then transferred automatically to a carrier under the chamber. In a DSE input stacker, the process is reversed. This paper gives framework on kinematics of the DSE stacker system in detail. The results of analyses show that the stacker system is valid.
引用
收藏
页码:555 / 566
页数:12
相关论文
共 13 条
  • [1] History, evolution, and trends in compound management for high throughput screening
    Archer, JR
    [J]. ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2004, 2 (06) : 675 - 681
  • [2] Liquid handling: Dispensing reliability
    Felton, MJ
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (17) : 397A - 399A
  • [3] Hitch J.R., 2000, U.S. Patent, Patent No. [6,099,230, 6099230]
  • [4] Cellular platforms for HTS: three case studies
    Johnston, PA
    Johnston, PA
    [J]. DRUG DISCOVERY TODAY, 2002, 7 (06) : 353 - 363
  • [5] Development of a Directly Self-adaptive Robot Hand with Pulley-belt Mechanism
    Li, Guoxuan
    Li, Bowen
    Sun, Jie
    Zhang, Wenzeng
    Sun, Zhenguo
    Chen, Qiang
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2013, 14 (08) : 1361 - 1368
  • [6] Syringe-pump-induced fluctuation in all-aqueous microfluidic system implications for flow rate accuracy
    Li, Zida
    Mak, Sze Yi
    Sauret, Alban
    Shum, Ho Cheung
    [J]. LAB ON A CHIP, 2014, 14 (04) : 744 - 749
  • [7] Liquid filling in standard circular well microplates
    Lu, Gabriel
    Tan, Han Yen
    Neild, Adrian
    Liew, Oi Wah
    Yu, Yang
    Ng, Tuck Wah
    [J]. JOURNAL OF APPLIED PHYSICS, 2010, 108 (12)
  • [8] The future of high-throughput screening
    Mayr, Lorenz M.
    Fuerst, Peter
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2008, 13 (06) : 443 - 448
  • [9] Design and fabrication of a screw-driven multi-channel peristaltic pump for portable microfluidic devices
    Rhie, Wonsei
    Higuchi, Toshiro
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (08)
  • [10] An improved method for checking HTS/uHTS liquid-handling systems
    Rhode, H
    Schulze, M
    Renard, S
    Zimmerman, P
    Moore, T
    Cumme, GA
    Horn, A
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2004, 9 (08) : 726 - 733