Comparison of Methodologies Using Estimated or Measured Values of Total Corneal Astigmatism for Toric Intraocular Lens Power Calculation

被引:51
作者
Ferreira, Tiago B. [1 ,2 ]
Ribeiro, Paulo [1 ]
Ribeiro, Filomena J. [3 ]
O'Neill, Joao G. [2 ]
机构
[1] Luz Hosp, Ave Lusiada 100, P-1500650 Lisbon, Portugal
[2] NOVA Med Sch, Lisbon, Portugal
[3] Fac Ciencias & Tecnol, Caparica, Portugal
关键词
ANTERIOR SEGMENT MEASUREMENTS; COHERENCE REFLECTOMETRY; REFRACTIVE OUTCOMES; PREDICTION; FORMULA; REPEATABILITY; KERATOMETRY; PRECISION; PENTACAM; IMPLANTATION;
D O I
10.3928/1081597X-20171004-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the prediction error in the calculation of toric intraocular lenses (IOLs) associated with methods that estimate the power of the posterior corneal surface (ie, Barrett toric calculator and Abulafia-Koch formula) with that of methods that consider real measures obtained using Scheimpflug imaging: a software that uses vectorial calculation (Panacea toric calculator: http://www.panaceaiolandtoriccalculator.com) and a ray tracing software (PhacoOptics, Aarhus Nord, Denmark). METHODS: In 107 eyes of 107 patients undergoing cataract surgery with toric IOL implantation (Acrysof IQ Toric; Alcon Laboratories, Inc., Fort Worth, TX), predicted residual astigmatism by each calculation method was compared with manifest refractive astigmatism. Prediction error in residual astigmatism was calculated using vector analysis. RESULTS: All calculation methods resulted in overcorrection of with-the-rule astigmatism and undercorrection of against-the-rule astigmatism. Both estimation methods resulted in lower mean and centroid astigmatic prediction errors, and a larger number of eyes within 0.50 diopters (D) of absolute prediction error than methods considering real measures (P < .001). Centroid prediction error (CPE) was 0.07 D at 172 degrees for the Barrett toric calculator and 0.13 D at 174 degrees for the Abulafia-Koch formula (combined with Holladay calculator). For methods using real posterior corneal surface measurements, CPE was 0.25 D at 173 degrees for the Panacea calculator and 0.29 D at 171 degrees for the ray tracing software. CONCLUSIONS: The Barrett toric calculator and Abulafia-Koch formula yielded the lowest astigmatic prediction errors. Directly evaluating total corneal power for toric IOL calculation was not superior to estimating it.
引用
收藏
页码:794 / 801
页数:8
相关论文
共 31 条
[1]   New regression formula for tonic intraocular lens calculations [J].
Abulafia, Adi ;
Koch, Douglas D. ;
Wang, Li ;
Hill, Warren E. ;
Assia, Ehud I. ;
Franchina, Maria ;
Barrett, Graham D. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (05) :663-671
[2]   Prediction of refractive outcomes with toric intraocular lens implantation [J].
Abulafia, Adi ;
Barrett, Graham D. ;
Kleinmann, Guy ;
Ofir, Shay ;
Levy, Adi ;
Marcovich, Arie L. ;
Michaeli, Adi ;
Koch, Douglas D. ;
Wang, Li ;
Assia, Ehud I. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) :936-944
[3]  
Ambrosio Jr R, OCULUS PENTACAM HR I, P6
[4]   Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement [J].
Aramberri, Jaime ;
Araiz, Luis ;
Garcia, Ane ;
Illarramendi, Igor ;
Olmos, Jaione ;
Oyanarte, Izaskun ;
Romay, Amaya ;
Vigara, Itxaso .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11) :1934-1949
[6]   Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye [J].
Chen, Davie ;
Lam, Andrew K. C. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :448-454
[7]   Comparison of 9 intraocular lens power calculation formulas [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1157-1164
[8]   Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power [J].
Davison, James A. ;
Potvin, Richard .
CLINICAL OPHTHALMOLOGY, 2015, 9 :1511-1517
[9]   Comparison of astigmatic prediction errors associated with new calculation methods for toric intraocular lenses [J].
Ferreira, Tiago B. ;
Ribeiro, Paulo ;
Ribeiro, Filomena J. ;
O'Neill, Joao G. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (03) :340-347
[10]   Variation in surgically induced astigmatism estimation due to test-to-test variations in keratometry [J].
Goggin, Michael ;
Patel, Ilesh ;
Billing, Kathryn ;
Esterman, Adrian .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10) :1792-1793