Effect of bond layer thickness on behaviour of steel-concrete composite connections

被引:27
|
作者
Kumar, Pankaj [1 ]
Patnaik, Amar [2 ]
Chaudhary, Sandeep [3 ]
机构
[1] Malaviya Natl Inst Technol Jaipur, Dept Civil Engn, Jaipur 302017, Rajasthan, India
[2] Malaviya Natl Inst Technol Jaipur, Dept Mech Engn, Jaipur 302017, Rajasthan, India
[3] Indian Inst Technol Indore, Discipline Civil Engn, Indore 453552, Madhya Pradesh, India
关键词
Steel-concrete composite; Structural adhesive; Push out test; Adhesive layer thickness; Shear stiffness; SHEAR CONNECTORS; STRUCTURAL BEHAVIOR; ANALYTICAL-MODELS; STATIC BEHAVIOR; ADHESIVE; STRENGTH; BEAM; RESISTANCE;
D O I
10.1016/j.engstruct.2018.07.054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance of steel-concrete composite structural members depends on the connection at the steel-concrete interface. Structural adhesives are gaining rapid recognition as the bonding material between steel and concrete interfaces. The thickness of adhesive layer in a composite connection plays a key role in maximising the bond capacity. In this paper, the effect of the change in thickness of adhesive layer on the capacity of connection, ultimate slip at the interface, and the shear stiffness of connection have been studied. Twenty-five test specimens were cast and tested under direct shear to achieve the optimum thickness of adhesive layer. The ultimate strength and relative slip of all five adhesive layer thicknesses of steel-concrete specimens, obtained through experimental studies, were verified using finite element analysis. The failure patterns of bonded connection were also critically observed and found to be varying with adhesive layer thickness. It changes from adhesive failure to mixed (adhesive and cohesive) failure, and from mixed failure to cohesive mode of failure, with increasing thickness. At the optimum thickness, the composite interface experiences a mixed mode of failure. The effectiveness of bonded connections over mechanical shear stud connections was outlined through a comparison of the load-slip behaviour of both.
引用
收藏
页码:268 / 282
页数:15
相关论文
共 50 条
  • [31] Non-traditional shear connections in steel-concrete composite structures
    Rovnák, M
    Duricová, A
    Ivanco, V
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 305 - 312
  • [32] Effect of silica fume and superplasticizer on steel-concrete bond
    Esfahani, M.R.
    Amirkabir (Journal of Science and Technology), 2001, 12 (45): : 35 - 42
  • [33] Behaviour of steel-concrete composite beam with high ribbed deck
    Thondel, S.
    Studnicka, J.
    STEEL STRUCTURES AND BRIDGES 2012 - 23RD CZECH AND SLOVAK INTERNATIONAL CONFERENCE, 2012, 40 : 457 - 462
  • [34] Steel-concrete composite flange plate connections: Cyclic performance and tests
    Kumar, S. R. Satish
    Smitha, M. S.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 82 : 216 - 222
  • [35] EFFECT OF CONDENSED SILICA FUME ON THE STEEL-CONCRETE BOND
    GJORV, OE
    MONTEIRO, PJM
    MEHTA, PK
    ACI MATERIALS JOURNAL, 1990, 87 (06) : 573 - 580
  • [36] Scaled Analysis of Steel-Concrete Composite Beam-Column Connections
    Dorka, Uwe E.
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 74 - 82
  • [37] An experimental study of steel-concrete composite connections equipped with fuse angles
    He, Xiuzhang
    Ke, Ke
    Chen, Yiyi
    Yam, Michael C. H.
    Shao, Tiefeng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 195
  • [38] Partial interaction behaviour of continuous composite steel-concrete beams
    Seracino, R
    Lee, CT
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 697 - 702
  • [39] An experimental study of steel-concrete composite connections equipped with fuse angles
    He, Xiuzhang
    Ke, Ke
    Chen, Yiyi
    Yam, Michael C. H.
    Shao, Tiefeng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 195
  • [40] Parametric modelling of the dynamic behaviour of a steel-concrete composite floor
    da Silva, Jose G. S.
    de Andrade, Sebastido A. L.
    Lopes, Elvis D. C.
    ENGINEERING STRUCTURES, 2014, 75 : 327 - 339