Experimental Behavior of Bridge Beams Retrofitted with Postinstalled Shear Connectors

被引:138
作者
Kwon, Gunup [1 ]
Engelhardt, Michael D. [2 ]
Klingner, Richard E. [2 ]
机构
[1] Sargent & Lundy LLC, Wilmington, DE USA
[2] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
关键词
Anchors; Bridges; Beams; Composite materials; Rehabilitation; COMPOSITE BEAMS;
D O I
10.1061/(ASCE)BE.1943-5592.0000184
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A number of older bridges were constructed with floor systems consisting of a noncomposite concrete slab over steel girders. A potentially economical means of strengthening these floor systems is to connect the existing concrete slab and steel girders with postinstalled shear connectors to permit the development of composite action. This paper presents the results of an experimental investigation of this concept. Five large-scale noncomposite beams were constructed, and four of these were retrofitted with postinstalled shear connectors and tested under static load. The retrofitted composite beams were designed as partially composite with a 30% shear connection ratio. A noncomposite beam was also tested as a baseline specimen. Test results showed that the strength and stiffness of existing noncomposite bridge girders can be increased significantly. Further, excellent ductility of the strengthened partially composite girders was achieved by placing the postinstalled shear connectors near zero-moment regions to reduce slip demand on the connectors. The test results also showed that current simplified design approaches commonly used for partially composite beams in buildings provide good predictions of the strength and stiffness of partially composite bridge girders strengthened using postinstalled shear connectors. DOI: 10.1061/(ASCE)BE.1943-5592.0000184. (C) 2011 American Society of Civil Engineers.
引用
收藏
页码:536 / 545
页数:10
相关论文
共 16 条
[1]  
ABAQUS, 2007, ABAQUS AN US MAN VER
[2]  
ACI (American Concrete Institute), 2008, 318R05 ACI
[3]  
[Anonymous], 2005, Standard Test Methods for Composition of Turpentine and Related Terpene Products by Capillary Gas Chromatography
[4]  
[Anonymous], 2005, A37005 ASTM
[5]  
[Anonymous], 2005, Specification for Structural Steel Buildings
[6]  
[Anonymous], 2008, THESIS U TEXAS AUSTI
[7]  
[Anonymous], 2007, LRFD BRIDG DES SPEC, V4th
[8]  
[Anonymous], 1951, B SERIES U ILLINOIS
[9]  
GRANT JA, 1977, ENG J AISC, V14, P24
[10]  
Hungerford B.E., 2004, THESIS U TEXAS AUSTI