摘要
Two chiral HPLC methods using protein-based stationary phases for the analysis of 8-hydroxy-(di-n-propylamino)tetralin and three 8-keto-pyrrole analogues are presented. Efficient solid-phase extraction enabled quantification of 0.02 mu g ml(-1) of the 8-keto-pyrrole analogues from 500 mu l rat hepatocyte suspensions, and 0.2 mu g ml(-1) to be measured from 50 mu l of rat plasma using UV detection at 315 nm.
引用
收藏
页码:1591 / 1599
页数:9
相关论文
共 15 条
[1]   SYNTHESIS OF R-(+)- AND S-(-)-8-HYDROXY-2-(N,N-DIPROPYLAMINO)-[2-H-3] TETRALIN - HCL (8-OH-DPAT) A 5HT1A RECEPTOR AGONIST [J].
ACKLAND, MJ ;
DRING, LG ;
JONES, JR ;
GILON, N .
JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 1991, 29 (08) :909-918
[2]  
Berridge JC., 1985, TECHNIQUES AUTOMATED
[3]   EVALUATION OF A NEW POLAR ORGANIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC MOBILE PHASE FOR CYCLODEXTRIN-BONDED CHIRAL STATIONARY PHASES [J].
CHANG, SC ;
REID, GL ;
CHEN, S ;
CHANG, CD ;
ARMSTRONG, DW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (04) :144-153
[4]   EXPERIMENTAL-DESIGN FOR THE RAPID SELECTION OF SEPARATION CONDITIONS FOR METHYL AND PROPYL PARAHYDROXYBENZOATE, PHENYLEPHRINE HYDROCHLORIDE AND CHLORPHENAMINE MALEATE BY ION-PAIR LIQUID-CHROMATOGRAPHY [J].
DEBEER, JO ;
VANDENBROUCKE, CV ;
MASSART, DL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (11) :1379-1396
[5]   METABOLISM OF AMINOTETRALIN ANALOGS INVIVO AND BY RAT HEPATOCYTES [J].
DUNCAN, JN ;
PARTON, T ;
ENOS, T .
BIOCHEMICAL SOCIETY TRANSACTIONS, 1990, 18 (06) :1200-1201
[6]   COMPARISON OF A NEW OVOMUCOID AND A 2ND-GENERATION ALPHA-1-ACID GLYCOPROTEIN-BASED CHIRAL COLUMN FOR THE DIRECT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY RESOLUTION OF DRUG ENANTIOMERS [J].
KIRKLAND, KM ;
NEILSON, KL ;
MCCOMBS, DA .
JOURNAL OF CHROMATOGRAPHY, 1991, 545 (01) :43-58
[7]  
MARTIN IJ, 1993, P BRIT PHARM SOC, pP163
[8]  
MORGAN ED, 1991, CHEMOMETRICS EXPT DE
[9]  
REES SA, 1992, METH SURV A, V22, P65
[10]  
Schoenmakers P.J., 1986, OPTIMIZATION CHROMAT