Application of coherent anti-Stokes Raman scattering (CARS) to imaging mammalian cells: A means for gaining molecular selectivity in multiphoton imaging

被引:4
作者
Holtom, G [1 ]
Thrall, B [1 ]
Weber, T [1 ]
Zhu, LY [1 ]
Hopkins, D [1 ]
Parkinson, C [1 ]
Colson, S [1 ]
Price, J [1 ]
Chin, BY [1 ]
Choi, A [1 ]
Risby, T [1 ]
机构
[1] Pacific NW Natl Labs, Environm Mol Sci Lab, Richland, WA USA
来源
MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES | 2001年 / 4262卷
关键词
CARS; Raman imaging; multiphoton fluorescence; confocal microscopy;
D O I
10.1117/12.424571
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Virtually all laser based microscopy imaging methods involve a single laser, with ultrafast lasers emerging as the enabling tool for a variety of methods. Two-photon fluorescence is a high sensitivity method with selectivity depending on a chromophore that is either added or produced by genetic engineering. While there are fundamental advantages over white light or other fluorescence microscopies, there are unavoidable limitations such as bleaching, photoinduced damage to the cell, and the inability to label some major constituents of the cell, particularly the abundant species. Raman imaging affords chemical selectivity but application is limited due particularly to its low sensitivity and unavoidable fluorescence background. Adding a second laser beam, shifted from the first laser by a molecular vibrational frequency, increases the detected Raman signal by many orders of magnitude and in addition shifts the detected signal to the high energy (blue) side of both lasers, removing fluorescence artifacts. Signal levels sufficient to acquire high signal-to-noise ratio images of 200 by 200 pixels in one minute requires sub-nanojoule pulse energy. A convenient, tunable source of the Stokes-shifted beam is provided by an Optical Parametric Amplifier (OPA), which requires an amplified laser. 250-kHz sources have ample energy and in addition keep the average sample power on the order of 0.1 mW, a level that even sensitive biological systems tolerate at the focal spot diameter of 0.3 mum. Long-term viability of mammalian cells has been demonstrated during dozens of scans in a single plane. Two-photon fluorescence provides a useful complimentary data channel that is acquired simultaneously with the Raman image. Several dyes and green fluorescence protein have been used for this purpose. Interpretation of images, acquiring three dimensional images, and identification of cellular features are ongoing activities.
引用
收藏
页码:319 / 328
页数:10
相关论文
共 9 条
[1]  
CHEN JX, IN PRESS JCP
[2]   SCANNING COHERENT ANTI-STOKES RAMAN MICROSCOPE [J].
DUNCAN, MD ;
REINTJES, J ;
MANUCCIA, TJ .
OPTICS LETTERS, 1982, 7 (08) :350-352
[3]  
KEES MQ, 2000, ANAL CHEM, V72, P12
[4]   3D microscopy of transparent objects using third-harmonic generation [J].
Müller, M ;
Squier, J ;
Wilson, KR ;
Brakenhoff, GJ .
JOURNAL OF MICROSCOPY, 1998, 191 :266-274
[5]  
Naumann D., 2000, INFRARED RAMAN SPECT, P323, DOI [DOI 10.1021/JA004845M, 10.1021/ja004845m]
[6]  
Pawley J.B., 1995, HDB BIOL CONFOCAL MI
[7]  
Schaeberle MD, 2000, INFRARED RAMAN SPECT, P231
[8]   2-PHOTON MOLECULAR-EXCITATION PROVIDES INTRINSIC 3-DIMENSIONAL RESOLUTION FOR LASER-BASED MICROSCOPY AND MICROPHOTOCHEMISTRY [J].
WILLIAMS, RM ;
PISTON, DW ;
WEBB, WW .
FASEB JOURNAL, 1994, 8 (11) :804-813
[9]   Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering [J].
Zumbusch, A ;
Holtom, GR ;
Xie, XS .
PHYSICAL REVIEW LETTERS, 1999, 82 (20) :4142-4145