The experimental behavior of FRP-strengthened RC beams subjected to design fire exposure

被引:97
作者
Ahmed, Aqeel [1 ]
Kodur, Venkatesh [1 ]
机构
[1] Michigan State Univ, Dept Civil & Environm Engn, E Lansing, MI 48824 USA
基金
美国国家科学基金会;
关键词
FRP-strengthened RC beams; Fire tests; Fire resistance; Design fire; Numerical model; Restrained RC beams; CONCRETE BEAMS;
D O I
10.1016/j.engstruct.2011.03.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The results from fire resistance experiments on five rectangular reinforced concrete (RC) beams are presented in this paper. Four of these RC beams were tested after being strengthened with carbon fiber reinforced polymer (CFRP), while the remaining one was tested as a control RC beam specimen. The beams were tested by exposing them to fire and service load, computed based on the nominal capacity of an unstrengthened/strengthened beam in accordance with ACI 318/ACI440.2R provisions. The test variables included type of fire exposure, anchorage zone, insulation type, and restraint conditions. The data from the fire tests is used to evaluate the thermal and structural response, as well as failure patterns in FRP-strengthened RC beams. The test results indicate that the anchorage configuration plays a critical role in limiting the deflections of the strengthened beam after debonding of the FRP occurs at T(g) +/- 10 degrees C, where T(g) is the glass transition temperature. Also, FRP-strengthened RC beams supplemented with 25 mm thick spray-applied insulation can survive failure under ASTM E119 standard fire or a design fire. Further, the fire-induced axial restraint force significantly increases the fire resistance of FRP-strengthened/unstrengthened RC beams, provided that the location of restraining force is below the geometric centroid of the beam and that the beam's deflection is sufficiently small along the entire span. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2201 / 2211
页数:11
相关论文
共 21 条
[1]   Effect of bond degradation on fire resistance of FRP-strengthened reinforced concrete beams [J].
Ahmed, A. ;
Kodur, V. K. R. .
COMPOSITES PART B-ENGINEERING, 2011, 42 (02) :226-237
[2]  
AHMED A, 2010, THESIS MICHIGAN STAT, P261
[3]  
[Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
[4]  
[Anonymous], 2008, BUILDING CODE REQUIR
[5]  
[Anonymous], 2001, 199112 EN EUR COMM S
[6]  
[Anonymous], D4065 ASTM
[7]  
[Anonymous], 2007, Concepts and Applications of Finite Element Analysis, DOI DOI 10.1016/B978-0-08-052402-3.50011-3
[8]   Performance in fire of small-scale CFRP strengthened concrete beams [J].
Barnes, Richard ;
Fidell, James .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (06) :503-508
[9]  
BISBY LA, 2003, THESIS QUEENS U KING, P365
[10]  
BLONTROCK H, 3 S 2000