Effects of High-Voltage Electrostatic Fields on the Quality of Tilapia Meat during Refrigeration

被引:30
|
作者
Hsieh, Chang-Wei [2 ]
Lai, Cheng-Hung [1 ]
Lee, Chia-Hsin [1 ]
Ko, Wen-Ching [1 ]
机构
[1] Da Yeh Univ, Dept & Grad Program BioInd Technol, Da Tsuen, Chang Hua, Taiwan
[2] Da Yeh Univ, Dept Med Bot & Hlth Care, Da Tsuen, Chang Hua, Taiwan
关键词
freshness keeping; high-voltage electrostatic field (HVEF); K-value; tilapia meat; SHELF-LIFE EXTENSION; FISH FRESHNESS; SPARUS-AURATA; STORAGE; SLAUGHTER; SYSTEM;
D O I
10.1111/j.1750-3841.2011.02218.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Fresh fish is typically brought to market refrigerated at approximately 4 degrees C, R-storage. A storage method has been devised that combines refrigeration with a high-voltage electrostatic field (100 kV/m; E-storage). It was developed to improve the quality and prolong the shelf life of foods. This study investigated changes in the freshness of tilapia meat under E-storage conditions. The total viable count of tilapia reached 10(7) CFU/g on the 7th d of refrigeration in R-storage. By the 6th d, K-value had increased from 20% to 61.7% for E-storage and to 94.7% for R-storage. Volatile basic nitrogen had increased from 12.54 mg/100 g to about 24.34 and 25.03 mg/100 g for R-and E-storage (on the 7th and 10th d), respectively. The sensory assessment also indicated that E-storage yielded an improvement in quality over that of R-storage. Practical application of the study model has the potential to prolong the freshness of fish.
引用
收藏
页码:M312 / M317
页数:6
相关论文
共 50 条
  • [21] HIGH-VOLTAGE EXPERIMENTS FOR ELECTROSTATIC INFLECTOR AND EXTRACTOR
    PAULIN, A
    ZORIC, T
    NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (03): : 369 - 376
  • [22] HIGH-VOLTAGE RHEOSTAT FOR ELECTROSTATIC ACCELERATOR FOCUSING
    KERN, BD
    COCHRAN, LW
    SCHNEIDER, KA
    HAHN, TM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1957, 28 (11): : 969 - 969
  • [23] STABILITY IMPROVEMENT OF AN ELECTROSTATIC HIGH-VOLTAGE GENERATOR
    BALOSSIER, G
    MERIENNE, E
    GENOTEL, D
    REVUE DE PHYSIQUE APPLIQUEE, 1978, 13 (06): : 313 - 316
  • [24] BACKGROUND INFORMATION ON HIGH-VOLTAGE FIELDS
    JANES, DE
    ENVIRONMENTAL HEALTH PERSPECTIVES, 1977, 20 (OCT) : 141 - 147
  • [25] PROTEIN SEPARATION IN HIGH-VOLTAGE FIELDS
    PARK, JK
    OH, CY
    CHANG, HN
    BIOSEPARATION, 1995, 5 (04) : 203 - 208
  • [26] Research on Direct Effects of High-voltage Electrostatic Field on Lactoperoxidase's Activity
    Ma, Xingke
    Du, Zhengwei
    Zhu, Min
    Mu, Bojia
    ADVANCES IN CHEMICAL ENGINEERING III, PTS 1-4, 2013, 781-784 : 372 - +
  • [27] Effects of high voltage atmospheric cold plasma treatment on microbial diversity of tilapia (Oreochromis mossambicus) fillets treated during refrigeration
    Wang, Jiamei
    Fu, Tengfei
    Sang, Xiaohan
    Liu, Yafu
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2022, 375
  • [28] Effect of high-voltage electrostatic field on post-harvest quality of cut roses
    Wang, Li
    Han, Yuan
    Zhang, Ying
    Feng, Zijian
    Wei, Shuyi
    JOURNAL OF PLANT INTERACTIONS, 2025, 20 (01)
  • [29] Application of High-Voltage Electrostatic Equipment to Ethylene Removal
    Li Weiqing
    Wang Jie
    Sun Jianfeng
    Li Weishuo
    INTERNATIONAL JOURNAL OF FOOD ENGINEERING, 2011, 7 (04)
  • [30] Measurement of fast high-voltage transients on electrostatic precipitators
    CSIRO Div of Applied Physics, Lindfield
    J Electrostatics, 3 (211-220):