Specific, simple and rapid detection of porcine circovirus type 2 using the loop-mediated isothermal amplification method

被引:25
作者
Zhao, Kai [1 ,3 ]
Shi, Wei [4 ]
Han, Fangting [4 ]
Xu, Yan [4 ]
Zhu, Lianlong [1 ,3 ]
Zou, Yong [2 ,3 ]
Wu, Xiao [1 ,3 ]
Zhu, Hong [1 ,3 ]
Tan, Furong [1 ,3 ]
Tao, Shiru [1 ,3 ]
Tang, Xueming [1 ,3 ]
机构
[1] Shanghai Acad Agr Sci, Biotechnol Res Inst, Shanghai 201106, Peoples R China
[2] Shanghai Acad Agr Sci, Inst Anim Sci & Vet Med, Shanghai 201106, Peoples R China
[3] Shanghai Acad Agr Sci, Key Lab Agr Genet & Breeding, Shanghai 201106, Peoples R China
[4] Shanghai Normal Univ, Coll Life & Environm Sci, Shanghai 200234, Peoples R China
关键词
MULTISYSTEMIC WASTING SYNDROME; REAL-TIME PCR; VIRUS; QUANTITATION; DNA; H5;
D O I
10.1186/1743-422X-8-126
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Porcine circovirus type 2 (PCV2) is the causative agent of postweaning multisystemic wasting syndrome (PMWS), and porcine dermatitis and nephropathy syndrome (PDNS). It has caused heavy losses in global agriculture in recent decades. Rapid detection of PCV2 is very important for the effective prophylaxis and treatment of PMWS. Results: A loop-mediated isothermal amplification (LAMP) assay was used to detect PCV2 in this study. Three pairs of primers were specially designed for recognizing eight distinct sequences of the ORF2 gene. This gene lies in the PCV2 virus genome sequence, and encodes the Rep protein that is involved in virus replication. Time and temperature conditions for amplification of PCV2 genes were optimized to be 55 min at 59 degrees C. The analysis of clinical samples indicated that the LAMP method was highly sensitive. The detection limit for PCV2 by the LAMP assay was 10 copies, whereas the limit by conventional PCR was 1000 copies. The assay did not cross-react with PCV1, porcine reproductive and respiratory syndrome virus, porcine epidemic diarrhea virus, transmissible gastroenteritis of pigs virus or rotavirus. When 110 samples were tested using the established LAMP system, 95 were detected as positive. Conclusion: The newly developed LAMP detection method for PCV2 was more specific, sensitive, rapid and simple than before. It complements and extends previous methods for PCV2 detection and provides an alternative approach for detection of PCV2.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Development and Evaluation of a Loop-Mediated Isothermal Amplification Method for Rapid Detection of Aspergillus fumigatus
    Tang, Qing
    Tian, Shuguang
    Yu, Nong
    Zhang, Xi
    Jia, Xiaodong
    Zhai, Hongyan
    Sun, Qun
    Han, Li
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (04) : 950 - 955
  • [42] Specific and rapid identification of the Pheretima aspergillum by loop-mediated isothermal amplification
    Huang, Qing
    Li, Zhiwu
    Ma, Zhiguo
    Li, He
    Mao, Runqian
    [J]. BIOSCIENCE REPORTS, 2019, 39
  • [43] Loop-Mediated Isothermal Amplification for Rapid and Reliable Diagnosis of Tuberculous Meningitis
    Nagdev, Khushboo J.
    Kashyap, Rajpal S.
    Parida, Manmohan M.
    Kapgate, Rajkumar C.
    Purohit, Hemant J.
    Taori, Girdhar M.
    Daginawala, Hatim F.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (05) : 1861 - 1865
  • [44] A Loop-Mediated Isothermal Amplification Method for Rapid Detection of NDM-1 Gene
    Qi, Jing
    Du, Yijun
    Zhu, Xiaoling
    Bai, Hua
    Luo, Yanbo
    Liu, Yuqing
    [J]. MICROBIAL DRUG RESISTANCE, 2012, 18 (04) : 359 - 363
  • [45] Rapid, Simple and Sensitive Detection of Q Fever by Loop-Mediated Isothermal Amplification of the htpAB Gene
    Pan, Lei
    Zhang, Lijuan
    Fan, Desheng
    Zhang, Xiuchun
    Liu, Hong
    Lu, Qunying
    Xu, Qiyi
    [J]. PLOS NEGLECTED TROPICAL DISEASES, 2013, 7 (05):
  • [46] Development and evaluation of a loop-mediated isothermal amplification assay for rapid and simple detection of Flavobacterium psychrophilum
    Fujiwara-Nagata, E.
    Eguchi, M.
    [J]. JOURNAL OF FISH DISEASES, 2009, 32 (10) : 873 - 881
  • [47] Detection of Botrytis cinerea by loop-mediated isothermal amplification
    Tomlinson, J. A.
    Dickinson, M. J.
    Boonham, N.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2010, 51 (06) : 650 - 657
  • [48] Development of loop-mediated isothermal amplification for rapid detection of Entamoeba histolytica
    Rivera, Windell L.
    Ong, Vanissa A.
    [J]. ASIAN PACIFIC JOURNAL OF TROPICAL MEDICINE, 2013, 6 (06) : 457 - 461
  • [49] A rapid detection method for the plant pathogen Sclerotinia sclerotiorum based on loop-mediated isothermal amplification (LAMP)
    Duan, Yabing
    Ge, Changyan
    Zhang, Xiaoke
    Wang, Jianxin
    Zhou, Mingguo
    [J]. AUSTRALASIAN PLANT PATHOLOGY, 2014, 43 (01) : 61 - 66
  • [50] Development of loop-mediated isothermal amplification for rapid detection of Entamoeba histolytica
    Windell L.Rivera
    Vanissa A.Ong
    [J]. Asian Pacific Journal of Tropical Medicine, 2013, (06) : 457 - 461